200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada - #1

/ 9


catalogue search
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 01
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 02
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 03
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 04
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 05
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 06
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 07
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 08
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada
P. 09
Pages:
200136 Seal-Leak Detection (SLD) Transducer - GE Energy Bently Nevada


See other catalogues for GE Energy Bently Nevada

Text version of the page
Specifications and Ordering Information Part Number 161736-01 Rev. D (10/08) Page 1 of 9 Bently Nevada™ Asset Condition Monitoring 200135 Dual Seal Leak flexiTIM™ Module and 200136 Seal Leak Detection Transducer Description The Seal Leak flexiTIM System consists of the 200136 Seal Leak Detection Transducer and the 200135 Dual Seal Leak flexiTIM Module. The Seal Leak Detection Transducer utilizes a sensor detecting the position of a diaphragm to measure the gauge pressure. The Dual Seal Leak flexiTIM Module provides two channels of static pressure, conditions the signals and sends the information into the Trendmasterâ 2000 system to display the pressure readings. It is designed as a scanning system as part of the Trendmaster 2000 system to measure pressure changes primarily near the seals on tandem-seal or dual seal pumps. It can also be used on single seal pumps if there is an expected pressure increase near the sensor of greater than 5% of full scale in the event of a seal failure. The Seal Leak Detection Transducer has a robust design to increase its survivability in harsh environments. It is able to withstand an occasional 10.3 bar (150 psig) water jet at the rear of the sensor and on the transducer cable. Cable seal adapters or conduit fittings protect the connectors to enable the entire system to withstand condensing humidity. The system is designed to meet IP66 for moisture ingression. The Transducer is also designed to withstand extremely high pressures caused by valve or seal failures without any degradation of the diaphragm, returning to normal operation when the pressure is within the Transducer’s specified range. The Seal Leak Detection Transducer is a robust, trending seal leak detection system. For higher accuracy pressure applications please refer to the 200132 Pressure Transducer and the associated datasheet.

pageCatalog pdf di En 2012-05-22-29