iOS . Pressing >
Automation
The 500 RL is available with a Super iOS that fullyautomates all validation protocols, including sys-
tem suitability. Protocol standards come in an
innovative vial cartridge which is easily inserted
into the Super >
USP Chapter <645> ConductivityMeasurement and Compliance
The 500 RL Analyzer meets all USP Chapter <645>Stage One regulatory monitoring requirements,
reporting raw conductivity, temperature, and tem-
perature compensated conductivity. Start on the displaymenu initiates a protocol, with no further user
action required. The 500 RL can also be pro-
grammed to restart
Toc analysis upon successful
completion of most protocols. >
Comprehensive Validation Support
Each 500 RL comes with professional and compre-
hensive IQ (Installation Qualification) and OQ
(Operation Qualification) documents. Optional PQ
(Performance Qualification) documentation is also
available for a complete validation solution. For
cleaning validation applications, an optional CV
Support Package provides protocols and docu-
mentation to guide users through the process of
validating TOC instrumentation for on-line CV. >
Security
The 500 RL Analyzer protects data and the
Analyzer from unauthorized user access. The 500
RL outputs encrypted data files for analysis and
system protocol results to a USB Flash memory
drive or serial port. The encrypted files can be
opened only in the Sievers DataShare* 500 program and can not be modified. For situations
where security is not a concern, non-encrypted
data files also may be exported in a .csv format.The optional Sievers DataGuard* software facili-tates compliance with 21 CFR Part 11 electronic
records regulations. DataGuard provides an
administratively controlled user-access system
supporting multiple users with unique passwords
and complete audit trail functionality. >
Simplicity
The advanced capability of the 500 RL is compli-
mented by user-friendly features that make it easy
and fast to install, operate, and maintain. The large,
color touch-screen menu provides access to all
Analyzer functions. In addition to displaying TOC
data, trend graphs, and Analyzer status, the color
interface provides real-time status of consum-
ables and prompts the user when semi-annual
maintenance is due. >
Easy, Stable Calibration
With 12-month calibration stability and easy screen
prompts to perform single-point or multi-point cali-
bration protocols, the 500 RL makes on-site calibra-
tion simple and convenient. Super iOS models allow
for vial set cartridge insertion, with no further oper-
ator action needed. >
Main Analyzer Display Screen