Electric Steam Boilers

T yp e GES - 12 KW to 180 KWTrimmed at 100 PSIG T yp e:GES

Bhp Condensate(Lbs./Hr.) Gaumer Catalog Number kW: Volts QuantityCircuits Quantity Switches Width(in.) Length(in.) Height(in.) Net Wt.(lbs.)
1.224 36.2
GES12-208
12 208 1
1
20
28 36 230
1.224 36.2
GES12-240
12 240 1
1
20
28 36 230
1.224 36.2
GES12-480
12 480 1
1
20
28 36 230
1.734 51.2
GES18-208
17 208 1
1
20
28 36 240
1.734 51.2
GES18-240
17 240 1
1
20
28 36 240
1.734 51.2
GES18-480
17 480 1
1
20
28 36 240
2.448 72.3
GES24-208
24 208 2
1
23
33 44 300
2.448 72.3
GES24-240
24 240 2
1
23
33 44 300
2.448 72.3
GES24-480
24 480 1
1
23
33 44 300
2.958 87.4
GES29-208
29 208 2
1
23
33 44 310
2.958 87.4
GES29-240
29 240 2
1
23
33 44 310
2.958 87.4
GES29-480
29 480 1
1
23
33 44 310
3.468 102.5
GES34-208
34 208 2
1
23
33 44 310
3.468 102.5
GES34-240
34 240 2
1
23
33 44 310
3.468 102.5
GES34-480
34 480 1
1
23
33 44 310
4.692 138.7
GES46-208
46 208 4
1
23
33 44 315
4.692 138.7
GES46-240
46 240 3
1
23
33 44 315
4.692 138.7
GES46-480
46 480 2
1
23
33 44 315
5.916 174.8
GES58-208
58 208 4
1
23
33 44 380
5.916 174.8
GES58-240
58 240 3
1
23
33 44 380
5.916 174.8
GES58-480
58 480 2
1
23
33 44 380
6.936 205
GES68-208
68 208 4
1
23
33 44 390
6.936 205
GES68-240
68 240 4
1
23
33 44 390
6.936 205
GES68-480
68 480 2
1
23
33 44 390
10.404 307
GES100-208
102 208 6
2
28
34 59 625
10.404 307
GES100-240
102 240 6
2
28
34 59 625
10.404 307
GES100-480
102 480 3
2
28
34 59 625
13.872 410
GES136-208
136 208 8
3
30
36 59 785
13.872 410
GES136-240
136 240 8
3
30
36 59 785
13.872 410
GES136-480
136 480 4
3
30
36 59 785
16.014 475
GES160-240
157 240 8
3
30
36 61 785
16.014 475
GES160-480
157 480 4
3
30
36 61 785
18.36 543
GES180-240
180 240 9
3
30
36 61 790
18.36 543
GES180-480
180 480 5
3
30
36 61 790

FACTORY INSTALLED OPTIONS

?

Low Pressure Trim 15, 30, and 50 are options. Please Specify.

???

Auxiliary Low Water Cut-off (Use GES81017) utilizes an amplifier with solid state (SCR) switching for control of automatic low water cutoff. When water level falls below a safe operation level the boiler is de-energized. A sensing device detects current flow between a submerged probe and the shell. The unit is available as a backup to the primary mechanical type low water cutoff control.Control Transformer with fused primary and fused/grounded secondaryAmmeter or Voltmeter - Contact Gaumer for options.

?

Single Phase Wiring - Available on GES12 - GES24. Please Specify.

?

SCR Stepless Control with 100% turndown capability. Contact Gaumer for options. 11/19/2001Page 2 of 3

GAUMER COMPANY, INC. · 13616 Hempstead Road · Houston · Texas · 77040 · Ph: 713.460.5200 Ph: 800.460.5200 · Fx: 713.460.1444 · Fx: 800.460.5700 · www.gaumer.com · sales@gaumer.com

662 662


pageCatalog pdf di En 2012-05-22-29