You may also be interested in
Heating element, Strip heater, Phosphating bath, Boiler, Air heater
Text version of the page
Electric Steam BoilersT yp e GES - 12 KW to 180 KWTrimmed at 100 PSIG T yp e:GESBhp Condensate(Lbs./Hr.) Gaumer Catalog Number kW: Volts QuantityCircuits Quantity Switches Width(in.) Length(in.) Height(in.) Net Wt.(lbs.)1.224 36.2GES12-20812 208 112028 36 2301.224 36.2GES12-24012 240 112028 36 2301.224 36.2GES12-48012 480 112028 36 2301.734 51.2GES18-20817 208 112028 36 2401.734 51.2GES18-24017 240 112028 36 2401.734 51.2GES18-48017 480 112028 36 2402.448 72.3GES24-20824 208 212333 44 3002.448 72.3GES24-24024 240 212333 44 3002.448 72.3GES24-48024 480 112333 44 3002.958 87.4GES29-20829 208 212333 44 3102.958 87.4GES29-24029 240 212333 44 3102.958 87.4GES29-48029 480 112333 44 3103.468 102.5GES34-20834 208 212333 44 3103.468 102.5GES34-24034 240 212333 44 3103.468 102.5GES34-48034 480 112333 44 3104.692 138.7GES46-20846 208 412333 44 3154.692 138.7GES46-24046 240 312333 44 3154.692 138.7GES46-48046 480 212333 44 3155.916 174.8GES58-20858 208 412333 44 3805.916 174.8GES58-24058 240 312333 44 3805.916 174.8GES58-48058 480 212333 44 3806.936 205GES68-20868 208 412333 44 3906.936 205GES68-24068 240 412333 44 3906.936 205GES68-48068 480 212333 44 39010.404 307GES100-208102 208 622834 59 62510.404 307GES100-240102 240 622834 59 62510.404 307GES100-480102 480 322834 59 62513.872 410GES136-208136 208 833036 59 78513.872 410GES136-240136 240 833036 59 78513.872 410GES136-480136 480 433036 59 78516.014 475GES160-240157 240 833036 61 78516.014 475GES160-480157 480 433036 61 78518.36 543GES180-240180 240 933036 61 79018.36 543GES180-480180 480 533036 61 790FACTORY INSTALLED OPTIONS?Low Pressure Trim 15, 30, and 50 are options. Please Specify.???Auxiliary Low Water Cut-off (Use GES81017) utilizes an amplifier with solid state (SCR) switching for control of automatic low water cutoff. When water level falls below a safe operation level the boiler is de-energized. A sensing device detects current flow between a submerged probe and the shell. The unit is available as a backup to the primary mechanical type low water cutoff control.Control Transformer with fused primary and fused/grounded secondaryAmmeter or Voltmeter - Contact Gaumer for options.?Single Phase Wiring - Available on GES12 - GES24. Please Specify.?SCR Stepless Control with 100% turndown capability. Contact Gaumer for options. 11/19/2001Page 2 of 3GAUMER COMPANY, INC. · 13616 Hempstead Road · Houston · Texas · 77040 · Ph: 713.460.5200 Ph: 800.460.5200 · Fx: 713.460.1444 · Fx: 800.460.5700 · www.gaumer.com · sales@gaumer.com662 662 |
|