General parameters Measuring principle: Performance: Operating temperature: Storage temperature: Response time, T90: Gas cell temperature: Sample gas: Flow rate: Sample gas pressure: FTIR (Fourier transform infrared) Simultaneous analysis of up to 50 gas components 20 ± 20 °C, non-condensing, dust free ambient air. -20 - +60 °C < 120 s, depending on the gas flow and measurement time 50-180 °C Non-condensing, particle free ~ 4 l/min Ambient Gasmet CONTINUOUS EMISSIONS MONITORING SYSTEM (CEMS) The Gasmet CEMS is especially designed for continuous emissions monitoring measurements (CEM) and for continuous process monitoring. Typical application for CEM is H2O, CO2, CO, N2O, NO, NO2, SO2, HCl, HF, NH3, CH4, C2H6, C3H8, and C2H4. The Gasmet CEMS can be easily to configured for a new set of compounds. Measured components and calibration ranges can be changed according to application. This technical data sheet describes one example of the system. The Gasmet CEMS is used for on-line measurements. It is an ideal tool to use for measuring trace concentrations of pollutants in wet, corrosive gas streams. All parts of the Gasmet CEMS are be heated up to 180 °C. It can be used for undiluted gases and the sample gases do not need drying beforehand. The Gasmet CEMS consists of Gasmet FTIR gas analyzer, Gasmet PC, Gasmet sampling system. As an option the system can be equipped with Gasmet oxygen analyser and/or with total hydrocarbon analyser (FID). All parts of the system are 19” rack mounted and are installed on the pull-out shelves. The Gasmet CEMS includes all power connections and temperature controllers for heated lines and heated sample probe. The operation of the system is fully automatic and controlled by the Calcmet software. Additionally all functions of the Gasmet CEMS can also be used manually. Gasmet PC and Calcmet application software control the CEMS. The measuring data can be transferred from the PC to the Control room with digital outputs (ModBus) or with analog outputs 4-20 mA. The alarms are transferred with relay contact. The Gasmet CEMS provides different alarm functions such as Function alarm, Service alarm and System alarm. Function and service alarms are associated with the Gasmet FTIR Gas Analyzer and with the Calcmet analysis software. A system alarm comes from Gasmet sampling system and it includes temperature alarms (from sample probe, heated lines, sampling unit), flow alarm and pressure alarm for zero gas. If any of the critical alarms is activated, instrument air starts to flow automatically into the system to prevent condensation. Standard CEMS is also equipped with a one span gas valve to allow automated span checks as required by the new legislation. Gasmet CEMS is air conditioned with a compressor-cooling unit on top of the cabin. Optionally cooling unit can be mounted on side of the cabin. Additional features of the Gasmet CEMS include multipoint sampling for two sample points and gas inlets for additional span gases. Gasmet CEMS is also supported by full remote control. STREET ADDRESS: Pulttitie 8 A 1 00880 Helsinki, Finland

Open the catalog to page 1
gasmet_cems - 2

Measuring parameters Heated lines Zero point calibration: Zero point drift: Sensitivity drift: Linearity deviation: Temperature drifts: Pressure influence: 24 hours, calibration with nitrogen (5.0 or higher N2 recommended) < 2 % of measuring range per zero point calibration interval None < 2 % of measuring range < 2 % of measuring range per 10 K temperature change 1 % change of measuring value for 1 % sample pressure change. Ambient pressure changes measured and compensated Tube size: Core material: Operating pressure: Temperature: Fittings: Power supply: Power density: 4/6 mm Teflon...

Open the catalog to page 2

All Gasmet Technologies catalogs and technical brochures

  1. DX4015

    2 Pages