|
|
See other catalogues for GarrettCom Europe
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Magnum ESD42 Dual-Homing Edge Switch | | | | | | | | | | PERFORMANCE: RJ-45 Ports Data Rate: 10 / 100 Mbps, FDX and HDX modes. Auto-negotiation and auto-cross MDI-MDIX on all RJ-45 ports Occurs at LINK-enable. No cross-over cables required. Fiber ports: 100Mb, all types of connectors for m-m, sgl-m. Fiber ports are factory set for FDX. RFQ for HDX internal settings Non-blocking switching, 128KB packet buffer memory Address buffer storage = 2K addresses | | | | | | Port Numbers: A | | | | | | RJ-45 PORT CONNECTORS: RJ-45 with auto-cross, 100BASE-TX and 10BASE-T: shielded 8-Pin female. Supports shielded (STP) and unshielded (UTP) Cat. 3, 4, 5. For PoE Pass-through option on 48VDC H and P models, request quote. LED INDICATORS, dual, top front and in end: POWER: ON for power applied 10/100 per RJ-45 port: Steady ON for 100 Mb, OFF for 10 Mb speed LK/ACT per port: Steady ON for LINK with no traffic, blinking for Activity. F/H per port in end: Steady ON for F/D mode, OFF for H/D mode. POWER SUPPLIES for AC (EXTERNAL): Power input DC jack (8 to 15V) is 2.5mm, center +ve, with 6ft. DC cord Input: 95-125vac at 60 Hz for "-d" models, 215-240vac at 50 Hz for "-i" models that have IEC power connector in the ext power unit. Input: 100-240vac at 47-63 Hz for "-Hd", "Hi" models, see footnote 1 Input: 100-240vac at 47-63 Hz for "-Pd", "Pi" models, see footnote 2 POWER INPUT OPTIONS for DC: 12VDC, internal (range of 8.0 to 15V DC), built-in screw terminal block for +, -, ground. The 12V DC jack is also present. 24VDC internal (range of 10 to 36V DC) built-in screw terminal for +, -, ground. The DC jack is also present, see footnote 3 -48V DC internal (range of 30 to 60V DC), built-in screw terminal block for +, -, ground. The 12V DC jack is also present. Note1: the 12V DC jack can be used for dual source DC power input Note2: internal DC power floats, user may ground + or - if desired. POWER CONSUMPTION: all models: 7.0 Watts typical. 9 Watts max. ALARM TERMINAL BLOCK, H and P Models, two screw terminals: Interna! 60VA relay contact: Open for Power Off, Closed for Power On AGENCY APPROVALS AND STANDARDS COMPLIANCE: UL listed (UL60950), cUL, CE, Emissions meet FCC Part 15, Class A. (see footnote 4) NEBS L3 and ETSI compliant, ncluding vibration, shock, and altitude H and P models: IEEE 1613 Env. Std for Electric Power Substations IEC61850 EMC and Operating Conditions Class C for Power Substations P model: NEMA TS-2 and TEES for traffic control equipment P model: designed for above-the-ceiling (plenum) installation | | | | | | | | | | 5 | | 6 | | | | | | | | | | 3 | | 4 | | | | | | | | | | rim Dual-Homing Ports | | | | | | | | | | NETWORK STANDARDS: Ethernet IEEE 802.3, IEEE 802.3u; IEEE 802.1p, 100BASE-TX, 10BASE-T, 100BASE-FX | | | | | | | | | | DUAL-HOMING: | | | | | | | | | | | Dual-Homing operation is plug-and-play. Ports 1 and 2 are peers. When the ESD42 is powered up, port 1 is initially used for upstream traffic providing that it can establish a Link signal. When there is a loss of Link on Port 1, all upstream traffic is moved to port 2 and port 1 becomes the standby port (after upstream fault repair). Port 2 will stay in operation indefinitely...until it experiences a loss of Link, whereupon the ESD42 will move all of the upstream traffic to port 1. Dual-Homing switch-over time is about 300 milliseconds. OPERATING ENVIRONMENT: Temperature: ESD42: the ambient temperature rating is 0°C to 40°C. ESD42H: the ambient temperature rating is -25°C to 60°C long term per independent agency tests (UL), or -40°C to 85°C short term per IEC Type Tests ESD42P: the ambient temperature ratings of -40°C to 75°C long term per indep. agency tests (UL), or -50°C to 100°C short term per IEC Type Tests. Storage temperature, all models: -40° to 185°F (-40°C to 85°C) Cold start: ESD42H model to -20°C, ESD42P model to -40°C Ambient Relative Humidity, all models: 5% - 95% (non-condensing) Altitude, all models: -200 to 50,000 ft. (-60 to 15,000m) Conformal coating (humidity protection) optional, request quote. PACKAGING: Enclosure: Robust sheet metal (aluminum) Dimensions of units: 3.6 in H x 3.0 in W x 1.7 in D (9.2 cm x 7.6 cm x 4.3 cm) Weight: ESD42 Switch Units: 9.5 oz (270g) Power Supply - d, i: 5.8 oz (165g) Power Supply - Hd, Hi: 5.8 oz (165g) Power Supply - Pd, Pi: 7.9 oz (225g) Cooling Method: Convection on regular model, case used as a heat sink on H and P models. | | | | | | | | | | WARRANTY: Three years | | | | | | Made in USA | | | | | | | | | | | | | | | | | | MOUNTING FOR ESD42 FAMILY OF SWITCH UNITS: Metal panel mounting clips: included DIN-Rail mounting option: Model # DIN-RAIL MC2, illustrated here; Rack-mount option: Model MC14-TRAY. Depth: 6.0", Width 17", Height 2.25"(15 cm D x 43cm W x 5.7cm H) | | 1: External 12V1A power supply, wall plug or power cord for North America AC receptacles. Temperature rating same as ESD42H, see above. (North America: for spare, order Model PSH-12V1A-Hd. Intl: order Model PSH-12V1A-Hi with IEC plug). 2: External 12V1A power supply, rated for outdoor temperatures same as ESD42P, see above. Universal AC input with recessed IEC plug. (North America: for spare, order Model PSP-12V1A-Pd, Intl: order Model PSP-12V1A-Pi with IEC plug). 3: For dual source 24V power input to DC jack, order Model DUAL-SRC-24KIT. 4: These products are tested are approved under IEC61850 for use in Class C sheltered locations where neither temperature nor humidity is controlled. The equipment needs to be protected against solar radiation, rainfall, other precipitations, and wind. UL has not approved these products for Annex-T outdoor use. ©2006 GarrettCom, Inc. Printed in United States of America Doc No. ESD42-R3 10/06 GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. GarrettCom, Magnum, Personal Switch, Link-Loss-Learn, SRing, Convenient Switch and Converter Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. NEBS is a registered trademark of Telcordia Technologies. UL is a registered trademark of Underwriters Labs. | | | | | | | | | | FIBER PORT CONNECTORS (for dual-homing ports 1 and 2): "ff" selections of the "fiber flavor" (see table below): Use 2ff for a 2-fiber 4-copper model, Iff for 1-fiber 5-copper model No entry in the "ff" field designates a 6-copper port ESD42 Switch. "1SC" or "2SC"= 100BASE-FX-SC: FO multi-mode with SC type, 2 km "1ST" or "2ST"= 100BASE-FX-ST: FO multi-mode with ST type, 2 km "1MTRJ" or 2MTRJ" = 100BASE-FX-MTRJ: FO m-mode w/ MTRJ, 2 km "1SSC" or "2SSC" = 100BASE-FX-SSC: FO single-mode with SC, 20 km "1SSCL" or "2SSCL"= 100BASE-FX-SSCL: sgl-m SC Long Reach 40 km "1SST" or "2SST" = 100BASE-FX-SST: FO single-mode with ST, 20 km "1SLC" or "2SLC" = 100BASE-FX-SLC: FO sgl-m with LC-type, 15 km For other fiber connector types, request quote. | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | Model No. | AMBIENT TEMPERATURE | | POWER I | NPUT | | | | | | 0° 40°C | -25° +60°C | -40° +75°C | 2 position | d,i AC external | Hd, Hi AC external + 12V T.B. | Pd, Pi AC e xternal + 12V T.B. | 12V DC Term. Block | 24V DC Term. Block | -48V DC Te rm. Block | Panel Clips included or DIN-Rail | | | | 1 ESD42-ff-d, i | X | | | | X | | | | | | X | | | | | | | | | ESD42H-ff-Hd, Hi | | X | | X | | X | | X | | | X | | | | ESD42H-ff-1 2VDC | | X | | X | | | | X | | | X | | | | ESD42H-ff-24VDC | | X | | X | | | | | X | | X | | | | ESD42HR-ff-24VDC | | X | | X | | | | | X | | DIN-Rail | | | | ESD42H-ff-48VDC | | X | | X | | | | | | X | X | | | | | | | | | ESD42P-ff-Pd,Pi | | | X | X | | | X | X | | | X | | | | ESD42P-ff-1 2VDC | | | X | X | | | | X | | | X | | | | ESD42P-ff-24VDC | | | X | X | | | | | X | | X | | | | ESD42PR-ff-24VDC | | | X | X | | | | | X | | DIN-Rail | | | | ESD42P-ff-48VDC | | | X | X | | | | | | X | X | | | | | | | | | | | | | | | | | | | | | | | | GarrettCom | | | | | | | | | | GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 PH: (510) 438-9071 FAX: (510) 438-9072 Email: mktg@garrettcom.com Web: www.GarrettCom.com | | | | | | | | | | | | | | I Factory Floor | | | | | | Office & wiring closet | | | | | | Outdoors | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|