• Products
  • Catalogs
  • Projects
  • News & Trends
  • Exhibitions

Front-End Module Datasheets - EMI filter up to 50 W - 10 Pages

Add to MyDirectIndustry favorites
Front-End Module Datasheets - EMI filter up to 50 W
  1. P. 1

  2. P. 2

  3. P. 3

  4. P. 4

  5. P. 5

  6. P. 6

  7. P. 7

  8. P. 8

  9. P. 9

Catalog excerpts

? MIL-STD-461D/E/F Part 2. & 3. requirements : ? Conducted Emission (CE) ? ? Conducted Susceptibility (CS) CE102, power leads, emission over 10KHz to 10MHz, basic curve ? ? ? CS114, bulk cable injection, frequency 10KHz to 400MHz, CS115, spikes, bulk cable injection, calibrated spike CS101, power leads, frequency 30Hz to 150KHz, curve #1 > ? DO-160-C/D/E/F requirements : ? Conducted Emission (CE) ? ? Conducted Susceptibility (CS) Section 21 power lines, emission over 15KHz to 30MHz, category B, AZ & LMH ? Section 20 power lines, frequency 10KHz to 400MHzIn addition, this filter withstands in a transparentstate without dammage the transient and spike requirements of : To comply with MIL-STD-461D/E/F power leads :Օ CE 102 : Emission requirement over 10KHz to 10MHz CS 101 : Susceptibility requirement over 30Hz to 150KHz Օ CS 114 : Susceptibility requirement over 10KHz to 400MHz CS 115 : Susceptibility requirement for spikesՕ To comply with MIL-STD-461C power leads : CE 03 : Emission requirement over 15KHz to 50MHzՕ CS 01 : Susceptibility requirement over 30Hz to 50KHz CS 02 : Susceptibility requirement over 15KHz to 400MHz Օ CS 06 : Susceptibility requirement for spikes To comply with DO-160C/D/E/F power lines :Օ Conducted emission requirement over 15KHz to 30MHz Conducted susceptibility requirement over 10KHz to 400MHzՕ Susceptibility requirement for induced transients Temperature range : Օ operating temperature : -40C/+105аC case storage temperature : -55հC/+125C ? from 4W up to 50W power ? MIL-STD-704A with 80V/100ms & 600V/10еs ? up to 2A input current ? MIL-STD-1275B with 100V/50ms & 250V/70sThe FGDS-2A-50V is suitable for all GAIA Converter DC/DC converters and architecture ? up to 50V permanent input voltage. Օ the US MIL-STD-461 rev C, D, E and rev F ? the international DO-160 rev C, D, E and rev FIn particular, the filter module is compliant withthe following requirements of MIL-STD-461 standards : > The GAIA Converter filter module FGDS-2A-50V provides a state-of-the-art product to fulfill Electromagnetic Interferences (EMI) requirements for Aerospace/Defence applications. The FGDS-2A-50V complies with major standards including : ? MIL-STD-461C Part 2. & 3. requirements : Conducted Emission (CE) ? ? CE03, power leads, emission over 15KHz to 50MHz, narrowband, Class A1 CE03, power leads, emission over 15KHz, broadband, Class A1 curve# 1 & 2 ? ? Conducted Susceptibility (CS) ? CS06, power leads, spike #1 CS02, power leads, frequency 15KHz to 400MHz, class A1 ? CS01, power leads, frequency over 30Hz to 50KHz, class A1, consult factory for criteria > (/T) : option for -55հC start up operating temperature.(/S) : option for screening and serialization REDEFINING THE SOURCE OF POWER Gaia Converter FC05-050.10/08 Revision C For locations, phone, fax, E-Mail see back cover size="-1">

 Open the catalog to page 1

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Times New Roman", serif; } .font1 { font:13.00pt "Times New Roman", serif; } .font2 { font:5.00pt "Trebuchet MS", sans-serif; } .font3 { font:7.00pt "Trebuchet MS", sans-serif; } .font4 { font:10.00pt "Trebuchet MS", sans-serif; } .font5 { font:13.00pt "Trebuchet MS", sans-serif; } S 7AIA I ' tpT^^^i I EMI Filter FGDS-2A-50V| Gradel 3- Electrical Spcifications Data are valid at +25°C, unless otherwise specified. r Parameter Conditions Limit or typical Units FGDS-2A-50V ^ Input Nominal input voltage Full temperature range...

 Open the catalog to page 2

The GAIA Converter FGDS-2A-50V is suitable for all GAIA Converter DC/DC converters and combinations : ? from 4W up to 50W total input power and up to 2A input current ? up to 50V permanent input voltage and up to 100V transient input voltage during 50ms > The GAIA Converter FGDS-2A-50V can be used directly in front of any DC/DC converter and combinationsusing of MGDM-04, MGDM-10, MGDM-18, MGDM-20, MGDM-26 and CGDM series. For better EMI performance andstability purpose, GAIA Converter recommends to use a RC cell (see section 4-4) together with a common mode noise capacitance Cc (10nF typical)...

 Open the catalog to page 3

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Tahoma", sans-serif; } .font1 { font:6.00pt "Times New Roman", serif; } .font2 { font:8.00pt "Times New Roman", serif; } .font3 { font:10.00pt "Times New Roman", serif; } .font4 { font:5.00pt "Trebuchet MS", sans-serif; } .font5 { font:7.00pt "Trebuchet MS", sans-serif; } .font6 { font:10.00pt "Trebuchet MS", sans-serif; } .font7 { font:13.00pt "Trebuchet MS", sans-serif; } I ' tpT^^^l I AIA EMI Filter FGDS-2A-50VJ Grade| 4- EMI Filter Electrical Schematics (continued) 4-4 R*C* Network Discussion The RC damping network is...

 Open the catalog to page 4

The conducted noise emission measurementmethod of MIL-STD-461C is described in MIL- STD-462C standard. The DUT˻ (Device Under Test) is powered thru a 1 meter lengh parallel wire.One end is terminated with the DUT and the otherend is terminated with 10F capacitors to the ground plane. The measurements are made with a current probe, the unit of measurement being dBյA. Current probeTo 50 ohms input+28V out+28V in Return outReturn in10F10յF The conducted noise emission measurementmethod is described in the MIL-STD-461D/E stan- dards. The DUT˻ (Device Under Test) is powered thru a 2 meters length parallel...

 Open the catalog to page 5

Gaia Converter FC05-050.10/08 Revision C For locations, phone, fax, E-Mail see back cover size="-1">

 Open the catalog to page 6

7 > Gaia Converter FC05-050.10/08 Revision C For locations, phone, fax, E-Mail see back cover size="-2">

 Open the catalog to page 7

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Trebuchet MS", sans-serif; } .font1 { font:7.00pt "Trebuchet MS", sans-serif; } .font2 { font:10.00pt "Trebuchet MS", sans-serif; } .font3 { font:13.00pt "Trebuchet MS", sans-serif; } EMI Filter FGDS-2A-50V Hi-Rel Gradel 7- Environmental Qualifications The modules have been subjected to the following environmental qualifications. Characteristics Conditions Severity Test procedure Climatic Qualifications Life at high temperature Duration Temperature / status of unit Test D : 1.000 Hrs @ 105°C case, unit operating MIL-STD-202G...

 Open the catalog to page 8

All GAÏA CONVERTER catalogs and technical brochures