Catalog excerpts

(/T) : option for -55C start up operating temperature. (/S) : option for screening and serialization Transient Input Voltage Range Output Permanent n/a40 VDC/100 ms* 50 VDC/100 ms* B : 3.3 VDCC : 5 VDC or +/-5VDC E : 12 VDC or +/-12VDC F : 15 VDC or +/-15VDC CF : 5 VDC and +/-15 VDC C : 4,5-5,5 VDCH : 9-36 VDC J : 16-40 VDC > * Consult factory for details REDEFINING THE SOURCE OF POWER Gaia Converter FC97-008.08/06 Revision N For locations, phone, fax, E-Mail see back cover >

 Open the catalog to page 1

tr.row {} td.cell {} div.block {} div.paragraph {}

 Open the catalog to page 2

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:8.00pt "Arial", sans-serif; } .font1 { font:4.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:4.00pt "Georgia", serif; } .font4 { font:6.00pt "Georgia", serif; } .font5 { font:8.00pt "Georgia", serif; } .font6 { font:6.00pt "Trebuchet MS", sans-serif; } .font7 { font:8.00pt "Trebuchet MS", sans-serif; } .font8 { font:9.00pt "Trebuchet MS", sans-serif; } Iss asa S a s s ﯠ l l i ! 1111 i i 111i Ilii I i 3111 1 » 11 iilljll h « 111 i! li! ࠮iHji lil Ut »«Sh=i lit...

 Open the catalog to page 3

tr.row {} td.cell {} div.block {} div.paragraph {}

 Open the catalog to page 4

Data are valid at +25C, unless otherwise specified. ParameterConditionsLimit ortypicalUnitsTriple Output MGDT-04- J Input Nominal input voltageFull temperature rangeNominalVDC28Permanent inputvoltage range (Ui)Full temperature rangeMin. - Max.VDC16-40Transient input voltageFull load (consult factory)MaximumVDC/S50/0,1Start up input voltageFull loadMinimumVDC15,5Start up timeUi nominalNominal outputFull load : resistiveMaximumms200Reflected ripple currentUi nominal, full load at switchingfreq. BW = 20MHzMaximummApp30Input current in short circuitmode (Average)Ui nominalShort-circuitMaximummA30No...

 Open the catalog to page 5

Output Power (W) > (MGDS-04-C-C module) Output Power (W) > (MGDS-04-C-E module) Output Power (W) > (MGDS-04-C-F module) 838077747168 65 Output Current (mA) 8380777471 6865 83807774716865 input 9V input 9V input 18V input 9V input 18V > Efficiency (%) input 18V > Efficiency (%) Efficiency (%) input 36V input 36V input 36V > Output Power (W) > (MGDS-04-H-B module) Output Power (W) > (MGDS-04-H-C module) Output Power (W) > (MGDS-04-H-E module) 8380777471 6865 848178757269 66 848178757269 66 Output Current (mA) input 40V input 40V input 28V input 40V input 16V input 16V > Efficiency (%) Efficiency...

 Open the catalog to page 6

tr.row {} td.cell {} div.block {} div.paragraph {}

 Open the catalog to page 7

tr.row {} td.cell {} div.block {} div.paragraph {}

 Open the catalog to page 8

CharacteristicsConditionsLimit or typicalPerformances Operating ambient temperaturerange at full loadAmbient temperature *MinimumMaximum- 40C+ 85аCOperating case temperaturerange at full loadCase temperatureMinimumMaximum- 40C+105аCStorage temperature rangeNon functionningMinimumMaximum- 55C+ 125аCThermal resistanceRth case to ambient in free airnatural convectionTypical20C /W Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 105аC. The MGDM-04 series operating case temperature must not exceed 105C. The maximum ambient temperature...

 Open the catalog to page 9

tr.row {} td.cell {} div.block {} div.paragraph {}

 Open the catalog to page 10

11-1 Output Short Circuit Protection (SCP) > The short circuit protection device protects the moduleagainst short circuit of any duration and restores the mo- dule to normal operation when the short circuit is removed. It operates in hiccup˻ mode by testing periodically if an overload is applied (typically every 200ms recovery time). The overload detection threshold is typically 200% of maxi- mum current with a detection time lower than 5ms. detection time time recovery time recovery timex100Vo (%) 11-2 Output Overvoltage Protection (OVP) > The output overvoltage protection device protects external...

 Open the catalog to page 11

Gaia Converter FC97-008.08/06 Revision N For locations, phone, fax, E-Mail see back cover size="-1">

 Open the catalog to page 12

Gaia Converter FC97-008.08/06 Revision N For locations, phone, fax, E-Mail see back cover size="-1">

 Open the catalog to page 13

North American Headquarters GAA Converter Canada, Inc 4038 Le Corbusier LAVAL, QUEBEC - CANADA H7L 5R2 Tel. : (514)-333-3169 Fax : (514)-333-4519 International Headquarters GAϏA Converter - FranceZI de la Morandire33185 LE HAILLAN - FRANCETel. : + (33)-5-57-92-12-80 Fax : + (33)-5-57-92-12-89 Represented by : > Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use.These products are sold only according to...

 Open the catalog to page 14

All GAÏA CONVERTER catalogs and technical brochures