DC/DC Module Datasheet 26 Watts Series - 13 Pages

Add to MyDirectIndustry favorites
DC/DC Module Datasheet 26 Watts Series

Catalog excerpts

(/T) : option for -55C start up operating temperature(/S) : option for screening and serialization Input Voltage Range Output Permanent Transient B : 3.3 VDCC : 5 VDC E : 12 VDC F : 15 VDC H : 9-36 VDCJ : 16-40 VDC 40 VDC/100 ms*50 VDC/100 ms* > * Consult factory for details REDEFINING THE SOURCE OF POWER Gaia Converter FC99-041.07/06 Revision H For locations, phone, fax, E-Mail see back cover >

 Open the catalog to page 1

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial Black", sans-serif; } .font2 { font:16.00pt "Impact", sans-serif; } .font3 { font:5.00pt "Tahoma", sans-serif; } .font4 { font:6.00pt "Tahoma", sans-serif; } .font5 { font:7.00pt "Tahoma", sans-serif; } .font6 { font:10.00pt "Tahoma", sans-serif; } .font7 { font:11.00pt "Tahoma", sans-serif; } .font8 { font:18.00pt "Tahoma", sans-serif; } CONVERTER rAIA MGDM-26 Sries JGmrT 2- Product Slection (continued) r Input range Output Current Reference Options 9-36 VDC 3,3 VDC 6...

 Open the catalog to page 2

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Tahoma", sans-serif; } .font1 { font:6.00pt "Tahoma", sans-serif; } .font2 { font:11.00pt "Tahoma", sans-serif; } .font3 { font:19.00pt "Tahoma", sans-serif; } CONVERTER MGDM-26 Sries JGIfte 3- Electrical Spcifications Data are valid at +25°C, unless otherwise specified. Parameter Conditions Limit or typical Units Single Output MGDS-26 26 - H 26 - J Input Nominal input voltage Full temperature range Nominal VDC 20 28 Permanent input voltage range (Ui) Full temperature range Min. - Max. VDC 9-36 16-40 Transient input...

 Open the catalog to page 3

Output Power (W) > (MGDS-26-H-C module) Output Power (W) > (MGDS-26-H-E module) 868482 807876 8071747783 input 40V input 40V > Efficiency (%) input 28V input 28V > Efficiency (%) input 16V input 16V > Output Power (W) > (MGDS-26-J-B module) Output Power (W) > (MGDS-26-J-C module) 88868482 807876 88868482 807876 input 40V input 40V input 28V > Efficiency (%) Efficiency (%) input 28V input 16V input 16V > Output Power (W) > (MGDS-26-J-E module) Output Power (W) > (MGDS-26-J-F module) 3,453,403,353,30 3,253,20 5,155,10 5,055,004,95 4,90 input 28V input 28V > Output Voltage (VDC) Output Voltage...

 Open the catalog to page 4

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Tahoma", sans-serif; } .font1 { font:6.00pt "Tahoma", sans-serif; } .font2 { font:11.00pt "Tahoma", sans-serif; } .font3 { font:19.00pt "Tahoma", sans-serif; } .font4 { font:11.00pt "Times New Roman", serif; } CONVERTER MGDM-26 Sries JGIlhl 4- Switching Frequency Limit or typical Spcifications Switching frequency Fuit temp驩rature range Ui min. to max. No load to full load Nominal, fixed 1 MHz 5- Isolation Limit or typical Spedfications Isolation resistance 100 MOhm 6- Protection Functions r Characteristics Protection...

 Open the catalog to page 5

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Tahoma", sans-serif; } .font1 { font:6.00pt "Tahoma", sans-serif; } .font2 { font:9.00pt "Tahoma", sans-serif; } .font3 { font:11.00pt "Tahoma", sans-serif; } .font4 { font:12.00pt "Verdana", sans-serif; } CONVERTER MGDM-26 Sries 8- Electromagnetic Interfrence Electromagnetic Interf驩rence requirements according to MIL-STD-461C/D/E standards can be easily achieved as indicated in the following section. The following table resumes the different sections covered by these standards. r Standard Requirements MIL-STD-461D/E...

 Open the catalog to page 6

CharacteristicsConditionsLimit or typicalPerformances Operating ambient temperaturerange at full loadAmbient temperature *MinimumMaximum- 40C+ 85аCOperating case temperaturerange at full loadCase temperatureMinimumMaximum- 40C+ 105аCStorage temperature rangeNon functionningMinimumMaximum- 55C+ 125аCThermal resistanceRth case to ambient in free airnatural convectionTypical7C /W Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 105аC. The MGDM-26 series operating case temperature must not exceed 105C. The maximum ambient...

 Open the catalog to page 7

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Tahoma", sans-serif; } .font1 { font:6.00pt "Tahoma", sans-serif; } .font2 { font:11.00pt "Tahoma", sans-serif; } MGDM-26 Sries 10- Environmental Qualifications The modules have been subjected to the following environmental qualifications. Characteristics Conditions Severity Test procedure Climatic Qualifications Life at high temperature Duration Temperature / status of unit Test D : 1.000 Hrs @ 105°C case, unit operating MIL-STD-202G Method 108A @ 125°C ambient, unit not operating Altitude level C 40.000 ft@-55°C...

 Open the catalog to page 8

11-1 Input Undervoltage Lock-out (UVLO) > An input undervoltage protection will inhibit the modulewhen input voltage drops below the lock-out turn-off threshold (see section 3 for value) and restores to normal operation automatically when the input voltage rises thelock-out turn-on threshold. UVLOTurn-on Turn-off UVLO VinOnOff 11-2 Output Short Circuit Protection (SCP) > The short circuit protection device protects the moduleagainst short circuit of any duration and restores the mo- dule to normal operation when the short circuit is removed. It operates in hiccup˻ mode by testing...

 Open the catalog to page 9

tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Tahoma", sans-serif; } .font1 { font:5.00pt "Tahoma", sans-serif; } .font2 { font:6.00pt "Tahoma", sans-serif; } .font3 { font:8.00pt "Tahoma", sans-serif; } .font4 { font:9.00pt "Tahoma", sans-serif; } .font5 { font:11.00pt "Tahoma", sans-serif; } .font6 { font:19.00pt "Tahoma", sans-serif; } .font7 { font:4.00pt "Times New Roman", serif; } CONVERTER MGDM-26 Sries JGIlhl 12- Description of Functions 13-1 Trim Function The primary output voltage Vo may be trimmed at -20%/ +10% via a single external trimpot or fixed...