AGM Batteries for General Purpose Service - HGL1.2-6 - FULLRIVER BATTERY - #1

/ 1


catalogue search
AGM Batteries for General Purpose Service - HGL1.2-6 - FULLRIVER BATTERY
P. 01
Page:
AGM Batteries for General Purpose Service - HGL1.2-6 - FULLRIVER BATTERY


See other catalogues for FULLRIVER BATTERY

Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:9.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Times New Roman", serif; } .font3 { font:7.00pt "Times New Roman", serif; } .font4 { font:8.00pt "Times New Roman", serif; } .font5 { font:10.00pt "Times New Roman", serif; } HGL1.2-6 77 , Terminal Linitmm A direction A direction Spécifications Discharge characteristics 77T(2f Nominal Voltage 6V Rated Capacity (20 hour rate) 1.2AH Dimension Total Height (with terminals) 58mm(2.28inches) Height 52mm(2.05inches) Length 97mm(3.82inches) Width 24mm(0.94inches) Weight Approx.0.31kg (0.68Ibs) (V) 6V Battery 6.5 §g 6.0 at5.5 g 5.0 1 4.5 er H 4.0 Temperature:25T!(77T) Characteristics Discharge time Capacity 77T(25TJ) 20 hour rate (60m A to 5.25Volts) 1.2AH 10 hour rate (110mA to 5.25Volts) 1.1AH 5 hour rate (200mA to 5.1Volts) 1.0AH 1 hour rate (720mA to 4.8Volts) 0.72AH Internal Resistance Full charged 77T(25^) 39m Q Standard Terminal F1 Capacity affected by Temperature (20 hour rate) 104T(40T5) 102% 77T(25TJ) 100% 32T(0Ç) 85% 5T(-15T5) 65% Self-Discharge 77T(25T!) Capacity after 3 month storage 91% Capacity after 6 month storage 82% Capacity after 12 month storage 64% Max. Discharge Current 77T(25TJ) 18A (5s) Maximum Charge Current(A) 240mA Charging (Constant Voltage) Cycle 7.25V~7.45V/77T(25T!) Float 6.8V~6.9V/77T(25T!) Temperature compensation coefficient of charging voltage (mV/T!/cell) Cycle -4mV/°C/cell Float -3mV/°C/cell Duration of discharge vs. Discharge current Dû O d o "S 3 Q Discharge current(A) Constant Current Disc peres @ 77T(25X5) Cut off voltage V/cell 15M 30M 45M 1H 2H 3H 5H 8H 10H 12H 20H 1.75V 1.96 1.19 0.85 0.69 0.39 0.29 0.20 0.137 0.112 0.095 0.060 Note The above data are average values, and can be obtained with 3 charge/discharge cycles. These are not minimum values. FULLRIVER HGL BATTERIES This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specification are subject to modification without notice. Contact Fullriver for the latest information.

pageCatalog pdf di En 2012-05-22-29