FuelCell Energy’s DFC3000® - FuelCell Energy - #1

/ 2


catalogue search
FuelCell Energy’s DFC3000® - FuelCell Energy
P. 01
FuelCell Energy’s DFC3000® - FuelCell Energy
P. 02
Pages:
FuelCell Energy’s DFC3000® - FuelCell Energy


See other catalogues for FuelCell Energy

Text version of the page
huelCell bnergy
Ultra-Clean, Efficient, Reliable Power
DFC3000
High Efficiency Low Environmental Impact Fuel Flexibility High Reliability Quiet Operation
of Plant (EBOP) ^
Advantages
FuelCell Energy's DFC3000™ system is the largest of the Direct FuelCell® (DFC®) power plant fleet, capable of providing high-quality baseload power with 47% electric power generation efficiency 24/7.Scalable up to 50 MW,the system is especially suitable for applications with larger load requirements such as hospitals, universities, manufacturing facilities, wastewater treatment plants, and utility/grid support.
2.8 MW,13.8kVAC 3,110 kVA,50 or 60 Hz
Fuel Cell Module
Performance
Power Output
Power @ Plant Rating
Standard Output AC Voltage Standard Frequency Optional Output AC Voltages Optional Output Frequency
Fuel Consumption
Natural gas (at 930 Btu/ft3)
Heat Rate,LHV
2,800 kW 13,800 V 60 Hz 12,700, 4,160 V
50 Hz
47 +/- 2 %
362 scfm 7,260 BTU/kWh
9 gpm 30 gpm
4.5 gpm 30 gpm
0.01 lb/MWh 0.0001 lb/MWh 0.00002 lb/MWh
980 lb/MWh 520-680 lb/MWh
Water Consumption
Average
Peak during WTS backflush
Efficiency
LHV
Water Discharge
Average
Peak during WTS backflush
Available Heat
Exhaust Temperature 700 +/- 50 °F
Exhaust Flow 36,600 Ib/h
Allowable Backpressure 5 iwc Heat Energy Available for Recovery
(to 250°F) 4,433,000 Btu/h
(to 120°F) 7,460,000 Btu/h
Pollutant Emissions
NOx
SOx PM10
Greenhouse Gas Emissions
CO2
CO2 (with waste heat recovery)

pageCatalog pdf di En 2012-02-07-15