Power factor correction systems in steel cabinets LSFC series Description Package automatic power factor correction systems in freestanding sheet steel cabinets. If required, also available with blocking filters for low voltage networks with a high proportion of harmonics. Power range 100 to 400 kVAr Design Cabinet with door and eyebolts for lifting, manufactured in sheet steel painted in DIN shade RAL 7032, ventilation via air inlet filter in cabinet door and outlet in top of cabinet, built-in electric fan if necessary. Modular construction combining up to four Type C capacitor modules. Components in cabinet: ” Self-healing power capacitors with low-loss polypropylene film dielectric and PCB-free filler, LKT series with discharge resistors to VDE 0560 Parts 46 + 47, IEC 60831-1 and .2 (EN 60831-1 and .2). ” Heavy duty capacitor contactors ” Fuse links, 3-pole, size NH00 ” Busbar system ” Control terminal strip with control circuit fuse and thermal trip contact ” RM 9606 or EMR 1100S reactive power control relays (not with LSFCZ units) ” If required, fan at top of cabinet, air inlet filter and temperature controller ” If required, low-loss blocking reactors with thermal trips Installation site The location where the cabinet is installed must comply with the requirements of the ingress protection and ambient temperature concerned. Regulations VDE 0100, VDE 0105, VDE 0560 Part 46 and VDE 0106 Part 100 (German Association of Electrical Engineers) regulations must be complied with when installing and connecting up power capacitors in Germany. In other countries the equivalent local regulations must be followed. System expansion The easy-to-maintain design simplifies the task of extending existing installations, since it is only a matter of installing additional capacitor modules. If the required power rating is more than 400 kVAr, every basic unit can be extended by the addition of LSFCZ... extension units (without control relays). The basic units are equipped with RM 9606 (suffix .606) or EMR 1100S (suffix .111) reactive power control relays. All system types can also be supplied with EMR 1100 (suffix .112) control relays. Connections The power supply cable and the current transformer cable enter the bottom of the cabinet through a sliding gland plate and a cable clamp rail, the power supply being connected to the busbar system and the current transformer cable to the terminal strip provided. Note The harmonics generated within a low voltage network and those fed in from the medium voltage network can be amplified many times over due to resonance with the inductive and capacitive reactances active in the low voltage network. In particular, in industrial installations with loads that generate harmonics, network compatibility should first be checked, and if appropriate, power factor correction systems with blocking filters installed.

pageCatalog pdf di En 2012-05-22-29