Product data sheet HSC 120: Room humidistat Improving energy efficiency Enables humidity control devices to be switched on according to needs Properties • Monitoring and regulation of relative air humidity in rooms by controlling fans, drying units and air humidifiers • Variable relative humidity as setpoint based on printed scale in % rh • Measurement taken via a measuring element of stabilised synthetic textile tape. • Micro-switch with fixed switching difference XSd Technical data Setting accuracy Power supply Switching difference Typ. 6% rh Long-term stability Approx. -1.5% rh/a Time constant in moving air (0.2 Approx. 5 min Ambient conditions Operation Humidity (non-condensing) 30...90 %rh Storage and transport Humidity (non-condensing) 10...95 %rh Structural design Housing Pure white (RAL 9010) Housing material Fire-retardant thermoplastic Screw terminals For wire of up to 1.5 mm2 Ingress protection IP 20 (EN 60529) Protection class II (IEC 60730) Overview of types Type Features HSC120F001 External setpoint adjuster HSC120F010 Internal setpoint adjuster The setting accuracy of the humidistat is valid for the calibration point ±5% rh at 55% rh and 23 °C following initial calibration at the factory. See diagram “Setting accuracyIn general, humidity sensors (humidistats) are subject to increased ageing if they are used and/or stored in very contaminated air or aggressive gases. The humidistat may start to drift and its linearity may change under these conditions. If the humidistats are used in very contaminated air, the warranty does not cover a premature re-calibration or the replacement of the complete humidistat WSAUTER Right of amendment reserved © 2014 Fr. Sauter AG

Open the catalog to page 1
HSC 120: Room humidistat - 2

Product data sheet Accessories Type Description 0362225001 Intermediate plate, pure white, for wall mounting on recessed junction box Additional information Fitting instructions WSAUTER Right of amendment reserved © 2014 Fr. Sauter AG

Open the catalog to page 2
HSC 120: Room humidistat - 3

Product data sheet Dimension drawing Right of amendment r es er ved © 2014 Fr. Sauter AG Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2014 Fr. Sauter AG

Open the catalog to page 3

All Fr. Sauter AG catalogs and technical brochures

  1. EQJW 24

    8 Pages

  2. NRT 101

    8 Pages

  3. Thermowells

    6 Pages

  4. SAUTER EGQ

    4 Pages

  5. TFL 201

    3 Pages

  6. TLC

    2 Pages

  7. SAUTER FACTS

    28 Pages