HSC 101: Panel-mounted humidistat (packing unit: 50 pieces)
3Pages

{{requestButtons}}

Catalog excerpts

HSC 101: Panel-mounted humidistat (packing unit: 50  pieces) - 1

Product data sheet 24.015 Produc t data sheet 24.015 HSC 101: Panel-mounted humidistat (packing unit: 50 pieces) How energy efficiency is improved Enables humidity control devices to be switched on according to needs. • Monitoring and regulation of relative air humidity by controlling fans, drying units and air humidifiers • Adjustment of change-over point via setpoint adjustment axis • Suitable for fitted applications with protection class II • Measurement via a measuring element of stabilised synthetic textile tape • Secured with bolting hole and fixing hole (blind hole) • Micro-switch with single-pole change-over contacts and fixed switching difference • Suitable for panel-mounted units only Technical data Power supply Max. load Long-term stability Time constant in moving air (0.2 m/s) Temperature influence Humidity (non-condensing) Humidity (non-condensing) Electrical connection Protection class Setting range Ambient conditions Operation Storage and transport The setting accuracy of the humidistat is valid for the calibration point ±5% rh at 55% rh and 23 ° f ollowing C initial calibration at the factory. See diagram “Setting accuracy”. In general, humidity sensors (humidistats) are subject to increased ageing if they are used and/or stored in very contaminated air or aggressive gases. The humidistat may start to drift and its linearity may change under these conditions. If the humidistats are used in very contaminated air, the warranty does not cover a premature re-calibration or the replacement of the complete humidistat Can be substantially improved by recalibration during usage The fitting method must adhere to the relevant safety standards Right of amendment reserv

Open the catalog to page 1
HSC 101: Panel-mounted humidistat (packing unit: 50  pieces) - 2

Product data sheet Overview of types Type Panel-mounted humidistat Additional information Fitting instructions Description of operation When the relative air humidity is increasing and setpoint XS is reached, the single-pole change-over contacts are activated (contact 1-2 is opened and 1-3 closed). The setpoint corresponds to the upper change-over point. The contacts are reset when the humidity value falls below the upper change-over point again by the amount of the fixed switching difference XSd. At temperatures other than the compensation temperature, the change-over point is shifted...

Open the catalog to page 2
HSC 101: Panel-mounted humidistat (packing unit: 50  pieces) - 3

Product data sheet Connection diagram Dimension drawing Right of amendment r es er ved © 2014 Fr. Sauter AG1.8 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2014 Fr. Sauter

Open the catalog to page 3