EQJW 245: Heating controller with two control loops for local or district heating, equitherm How energy efficiency is improved Function for time-optimised switching on/off of heating. Limitation of the maximum admissible temper- atures for the heating and the drinking water ■ Weather-dependent supply-temperature control and heating of drinking water ■ Convenient to use with modern operating concept (turn and press) and large LCD • Communication via Modbus/RTU or proprietary device bus • Convenient weekly and calendar switching programmes with optimisation of switching times • Automatic summertime/wintertime changeover • Two independent control loops • Min./max. limitation for supply and return temperatures • Frost-protection facility and anti-jamming function for valve and pump • Screed curing (floor-drying function) • Function for protecting against legionellae • Connection of room temperature via room-temperature sensors or room operating unit ■ Nil 000 inputs for the outside, supply, drinking water, return flow and room temperatures or for the room operating unit • Relay outputs for activating control units, pumps, additional multifunctional relay output • Pulse input for measuring and limiting flow or energy • Manual mode • Notification by text message Technical data Power supply Control characteristic Supply temperature_ PI control _ Control parameters Proportional band_2...100 K_ Integral action time 15...1000 s Switching difference for drinking wa- 1 ...19 K Temperature ranges Normal temperature_0...40 °C_ Running time of valve 30...300 s_ Cycle time Running time of the valve + 15 Ambient conditions Admissible ambient temperature 0...50 °C Admissible ambient humidity 5...95% rh, no condensation Storage and transport temperature -25...65 °C_ Number of outputs 8 relays SAUTER Right of amendment reserved © 2015 Fr. Sauter AG

Open the catalog to page 1
EQJW 24 - 2

Product data sheet Configurable relay3) Number of inputs Switching current approx. 1mA Analogue inputs Operation Timer 1 digital or pulse, 8 analogue Digital inputs 6 Ni1000, 2 Ni1000 or room operating unit Back-up power supply Number of switching commands Weekly switching programme Min. switching interval Calendar switching programme Number of switching commands RS-485, device interface (similar to RS-232) Housing material Fire-retardant thermoplastic Structural design Wall, panel and top-hat rail Screw terminals Standards and directives Type of protection (when fitted in pan- IP 40 (EN...

Open the catalog to page 2
EQJW 24 - 3

Product data sheet controller. The microprocessor in the controller uses these values to calculate the signals for the outputs. Using the stored control model, the calculation of the output signals is based on the specified setpoints, the current control offset, the set control parameters and the operating mode, along with the current actual values. These signals are processed further via switching amplifiers. The results are the ON/OFF commands of the relay outputs for the control unit(s) and the pumps. The room is supplied with the heat required to keep the room temperature constantly at...

Open the catalog to page 3
EQJW 24 - 4

Product data sheet Actual value Actual value of the supply temperature Room-temperature setpoint Additional technical data Measuring accuracy Time constant for processing of measured values Neutral zone for supply temperature Minimum pulse duration for control 250 ms unit Follow-on time for heating pump Heating characteristic Curved, without influence of extraneous heat Damping of outside temperature Can be set on the SERVice level with time constants up to approx. 48 hours; can be (de)activated Summertime/wintertime heating limit ON means summer → winter OFF means winter → summer ON for...

Open the catalog to page 4
EQJW 24 - 5

Product data sheet Anti-jamming function for pump The anti-jamming function for the pump is enabled on the SERVice level. Every day at midday, a pump is activated for approx. 60 seconds if it has not been operated for the previous 24 hours. This function is active in all operating modes apart from the manual mode. Multifunctional relay output One of the output relays (terminal 12) can be parameterised for a wide range of functions. This means the output can be used as a pilot clock output, as a collective alarm, for controlling a circulation pump or a 2nd charging pump. It is also possible...

Open the catalog to page 5
EQJW 24 - 6

Product data sheet Characteristics Heating characteristics for foot point TI = 20 °C Slope 2,5 Flow temp. Outside temp. Limiting characteristic of the return temperature TRF max. TL0 (RF) TL0BW (RF) Control models • Weather-dependent supply-temperature control (secon- • Weather-dependent supply-temperature control (secondary) with additional control valve in the secondary cir- dary) with drinking-water control via control valve in the cuit for 2nd heating circuit • Weather-dependent supply-temperature control (secon- • Weather-dependent supply-temperature control for 2 dary) for a maximum...

Open the catalog to page 6
EQJW 24 - 7

• Weather-dependent supply-temperature control and drinking water circuit via separate control valve • Weather-dependent supply-temperature control for 2 zones with connection of the drinking water circuit via a control valve • Weather-dependent supply-temperature control for one zone via a control valve and direct connection of the drinking water circuit and a second zone • Weather-dependent supply-temperature control (secon- dary) and direct connection without mixing control for drinking water circuit Connection diagram WSAUTER Right of amendment reserved © 2015 Fr. Sauter AG

Open the catalog to page 7
EQJW 24 - 8

Product data sheet Dimension drawing Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61 - 695 55 55 www.sauter-controls.com Right of amendment reserved © 2015 Fr. Sauter AG