Catalog excerpts
23.115/1 DFC 17B, 27B: Heavy-duty pressure switch How energy efficiency is improved Demand-led controlling and monitoring; no external energy source required. Areas of application For regulating and monitoring pressures in liquids, gases and vapours. Especially suitable for equipment that is subject to vibrations. Features Pressure range: -1 to +50 bar Contact rating: 1 mA, 6 V to 10 A, 400 V Up to 110 °C media temperature Gold-plated silver contacts, vibration-proof snap-action switch with single-pole change-over switch Upper and lower switching points can be set independently Sealable As per PED (Pressure Equipment Directive) 97/23/EC, Cat. IV Technical description Light-alloy housing with transparent cover Splash-proof Ambient temperature: -40 to +70 °C IP 44 Brass sensor or stainless-steel for aggressive media, G ½", male thread, screw terminals for electrical conductor max. 2.5 mm², cable inlet PG 13.5 Contact rating as silver contacts max. Permissible ambient temp. Protection class Test marking 4) DWFS (SDBF) DWFS (SDB) DB (SDBF) PED for higher loading 10(2) A, 400 V~ 5) 6) (25 W), 250 V= min. 100 mA, 24 V as gold contacts 2) for lower loading max. 200 mA, 50 V min. 1 mA, 6 V Permissible vacuum loading –1,0 bar Type B30; B54 –0,7 bar Wiring diagram Dimension drawing Fitting instructions If under inductive load, take RC circuit into account If the contacts are ever loaded higher than 200 mA, 50 V, the gold plating will be damaged. The contacts are then classed only as silver contacts, since they lose the properties of gold contacts IP 54 with accessory 0259299000 Certificates can be downloaded from www.tuv.com 230/400 V networks From 70 °C media temperature, the current must be reduced to
Open the catalog to page 1Plug spanner for the setting screws. Cap nut with soldering nipple. Adaptor G½ to 7/16" 20-UNF-2A for connecting copper tubing of Ø 6 mm, brass. Screw connection for connecting copper tubes of Ø 6 mm, brass. Throttling screw for damping pressure surges; brass. Throttling screw for damping pressure surges; stainless steel. 1 m of capillary tubing for damping pressure surges; copper. 1 m of capillary tubing for damping pressure surges; steel. Damping screw for arresting pressure surges in low-viscosity media. Stainless steel. Bracket for off-wall mounting (already supplied with DFC 17 B...
Open the catalog to page 2Additional technical data Complies with:Low-Voltage Directive 2006/95/EC EMC directive 2004/108/EC PED 97/23/EC, Cat. IV (Pressure Equipment Directive) VdTÜV 1) 2) 3) EN 60730-1 EN 60730-2-6 EN 61000-6-1 EN 61000-6-2 EN 61000-6-3 EN 61000-6-4 Pressure information sheet 100 EN 12952-11 EN 12953-9 Electrical serviceable life for safety applications: cos 1)= 0.6…1: DFC 17B, DFC 27B 5,000 switchings 2) 250,000 switchings 3) Mechanical serviceable life cos = 0.3 is not permitted Based on VD-TÜV paper 100, section 6.2.3 Based on EN 12953.- / EN 12952-11, section 4.4.2.6 Technical notes RC...
Open the catalog to page 3Printed in Switzerland Right of amendment reserved N.B.: A comma between cardinal numbers denotes a decimal point © Fr. Sauter AG, CH-4016 Basle 7123115003 07 SAUTER Compone
Open the catalog to page 4All Fr. Sauter AG catalogs and technical brochures
-
SAUTER Catalogue
551 Pages
-
HSC 120: Room humidistat
3 Pages
-
SAUTER AXT2 and AXS2.
8 Pages
-
Ball valve and actuator.
6 Pages
-
SAUTER Valveco compact
8 Pages
-
Valves and actuators.
32 Pages
-
SAUTER vialoq AVM 100
2 Pages
-
ASM 134: Damper actuator
4 Pages
-
SAUTER flexotron ® 400
4 Pages
-
EXG: Active potentiometer
2 Pages
-
flexotron ® 2000
2 Pages
-
SAUTER flexotron800
8 Pages
-
EQJW 24
8 Pages
-
NRT 101
8 Pages
-
Thermowells
6 Pages
-
Indoor air quality
8 Pages
-
SAUTER EGQ
4 Pages
-
SAUTER equiflex ® NRT300
4 Pages
-
SAUTER HSC/HBC humidistats
2 Pages
-
DSA: Pressure switch
4 Pages
-
TFL 201
3 Pages
-
TUC: Universal thermostat
5 Pages
-
TLC
2 Pages
-
TSHK 670...67
3 Pages
-
TSHK 621...643
4 Pages
-
TSO, TSH: Room thermostat
4 Pages
-
RAK: Universal thermostat
5 Pages
-
SAUTER FACTS
28 Pages
-
Pressure transducer
3 Pages
-
Air-flow transducer
2 Pages