DynoSense 300
High scan rate: 3.3 kHz Broad wavelength window: 1520-1580 nm Easy user interface Integration time can be software controlled allowing adjustment of measured optical intensity range Standard specifications Optical parameters Unit Value Wavelength range nm 1520-1580 Number of Bragg sensors - 40 Number of optical lines - 1 Wavelength repeatability pm <5 Wavelength resolution pm <1 Wavelength accuracy* pm 35 Total dynamic range dB 20 Scan rate kHz 3.3 Optical connector - FC/APC Electronic parameters Digital data interface CameraLink Gigabit Ethernet (GigE) Power supply V 12 Operating conditions Humidity - non-condensing Operating temperature ° C -10 to 50°C Mechanical parameters Dimensions** WxDxH (mm) 117x240x120 Weight kg 2,5 Weight power supply kg 0.25 Connectors
Power connector Extra power connector if GigE
USB connector (control) External trigger connector CameraLink connector Optical connector
Fiber optic sensors and Sensing systems Cipalstraat 14 B-2440 Geel BelgiumT +32 14 58 11 91 F +32 14 59 15 14
info@fos-s.com www.fos-s.com
Features * Wavelength accuracy guaranteed over one year Information furnished by FOS&S is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. This information
supersedes all previously supplied information. >
Released: October, 2006