| | | | | | | | | | | | | | SVE 406 | SVE 465 | SVE 485 | SVE 411 | SVE 420 | SVE 065 | SVE 095 | | | | 0 6 mm | 0 6.5 mm | 0 8.5 mm | 0 11 mm | 0 22 mm | 0 6.5 mm | 0 9.5 mm | | | | 2 m | 2 m | 2m | 3 m | 6 m | 6 m | 6 m | | | | 4x140° | 4x140° | 4x120° | 4x110° | 4x110° | - | - | | | | 0° | 0 and 90° | 0 and 90° | 0 and 90° | 0 and 90° | 0 and 90° | 0 and 90° | | | | 85° | 55° | 55° | 55° | 55 or 130° | 55° | 55° | | | | 5 mm to oo | 15 mm to oo | adjustable | adjustable | adjustable | 15 mm to oo | adjustable | | | | 320000 | 470000 | 470000 | 470000 | 470000 | 470000 | 470000 | | | | 1/10" | 1/6" | 1/6" | 1/6" | 1/3" | 1/6" | 1/6" | | | | Tunflex | Tunflex | Tunflex | Tunflex | Polyurethane | Hytrel | Hytrel | | | | | | | | | | | | | | |
| | | |
| | | Video probe | | Probe 0 (1/10th mm) I -SVE 4 65 _I_ | | Probe length (dm) 20 06 C - | | |
| | | |
| | | I C : keyboard on probe \X : no keyboard on probe | | |
| | | |
| | | |
| | | |
| | | 4 4 positions articulation 2 2 positions articulation 0 no articulation | | |
| | | 06 10 | | 1/6" sensor 1/10" sensor | | |
| | | |
| | | |
| | | Reference Optical magnification Field Depth of field | | |
| | | |
| | | | | | | | | | | | | on 36 cm screen | (mm) | (mm) | | | | OC 25 | 1/2 x | 25 x | 13 x 10 | +/- 0.5 | | | | OC 50 | 1 x | 50 x | 6.5 x 5 | +/- 0.4 | | | | OC 100 | 2 x | 100 x | 3.3 x 2.5 | +/- 0.2 | | | | OC 200 | 4 x | 200 x | 1.6 x 1.3 | +/- 0.1 | | | | OC 400 | 8 x | 400 x | 0.8 x 0.6 | +/- 0.05 | | | | OC 800 | 16 x | 800 x | 0.4 x 0.3 | +/- 0.02 | | | | OC 1000 | 32 x | 1000 x | 0.2 x 0.15 | +/- 0.01 | | | | ONC 5 | 1/25 x | 5 x | 64 x 50 | +/- 5 | | | | ONC 10 | 1/5 x | 10 x | 32 x 25 | +/- 2 | | | | ONC 25 | 1/2 x | 25 x | 13 x 10 | +/- 0.5 | | | | ONC 50 | 1 x | 50 x | 6.5 x 5 | +/- 0.4 | | | | ONC 100 | 2 x | 100 x | 3.3 x 2.5 | +/- 0.2 | | | | ONC 200 | 4 x | 200 x | 1.6 x 1.3 | +/- 0.1 | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | | | |
| | | |
| | | | | | | | | | | colour sensor with very high colour rendition, this camera has a very high resolution and sensitivity. Fitted on a C-mount, the Lynx MC2 camera adapts perfectly to a wide range of commercial industrial lenses. | | | | | Video standard PAL Resolution 470000 pixels | Fort proposes a large range of endoscopes: - Boroscope; from diameter 1 to 10 mm; - Fibroscope; from diameter 0.5 to 11 mm. | | | | Sensor CCD 1/3" - sensibility < 1 lux Objective C mount objective Length of the cable 2.4 meters | | | | | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | |