| | | Force Control Industries, Inc. | | |
| | | Posidyne Oil Shear Clutch & Clutch/Brakes | | |
| | | |
| | | |
| | | example: to order a size 2.5 Posidyne 184tc c-face input, typea control logic, output housing to accept an encoder, horizontal mounting, basic radiant cooled, manifold mounted control valve and optical encoder located at the top. use the following order number: 2 5-4 A C-H-1 /_ / | | |
| | | How to Order Your Posidyne The Posidyne Ordering system has been developed to simplify the ordering process and to reduce any misunderstanding and costly errors. To correctly order a Posidyne it is necessary to determine the following information: Size, Input Module, Control Logic, Output Module, Mounting Position and Cooling Options. Just use the Ordering System Chart below along with the Option Availability Tables on the next page to I OMIUJUWIICLMLI | | |
| | | |
| | | |
| | | CONTROL VALVE T See Section 10 for Ordering Number. Use Nif no Valve is to be ordered. | | |
| | | j | | |
| | | |
| | | See Section 11 for Ordering Number. Use N if no Encoder is to be ordered. cooling (7) 1 = Basic (Radiant) ^| = Water Cooled Ji| = Fan Cooled*** j\ = Fan Cooled,*** Split Shroud 9 = Force Lube | | |
| | | size (1,2) 0J2 = Q2| 1|0 = io 05 = 25l 11 = 11 o[3 = 03l 14 = 14 JÏÏ5 = 051 2 0 = 20 | | |
| | | |
| | | |
| | | input module (3) | | |
| | | |
| | | | | | | | | | | | | \± | = Basic | U-Fr. | T-Fr. | | | | | 3 | = 4-1/2 FAK, 7/8 FU | 182 184 | 143TC 145TC | ~l C-Face Quill _l | | | | 4 | = 8-1/2 FAK, 1-1/8 FU | 213UC 215UC | 182TC 184TC | | | | 5 | = 8-1/2 FAK, 1-3/8 FU | 254UC 256UC | 213TC 215TC | | | | | = Piggyback & Ceiling Mount* | | | | 9 | = 4-1/2 FAK, 7/8 FU | 143TC 145TC | n C-Face Coupled 1 | | | | a | 213UC = 8-1/2 FAK, 1-1/8 FU 215UC | 182TC 184TC | | | | b | = 8-1/2 FAK, 1-3/8 FU | 213TC 215TC | | | | | | | | | | | | |
| | | |
| | | mounting position (6) h = Horizontal d = Vertical, Input Down u = Vertical, Input Up | | |
| | | put module = Basic | | |
| | | U-Fr. | | T-Fr. | | |
| | | |
| | | |
| | | 143TC 145TC | | |
| | | 182 | | |
| | | | | | | |
| | _3 = 4-1/2 AK, 7/8 U 184 | |
| | | = Wall on Left (Viewing Input) = Wall on Right (Viewing Input) | | |
| | | |
| | | l | | |
| | | |
| | | Q213UC = 8-1/2 AK, 1-1/8 U 215UC | | 182TC 184TC | | |
| | | C-Face | | |
| | | |
| | | |
| | | |
| | | |
| | | H254UC = 8-1/2 AK, 1-3/8 U j256UC | | 213TC 215TC | | |
| | | |
| | | |
| | | = Piggyback and Ceiling Mount* = Optical Encoder (02 to 20 Sizes)* (Not Available on C-Face Output) = Optical Encoder, 4-1/2 AK, 7/8 U (02 Only)** C-Face Encoder (Consult Factory) | | |
| | | |
| | | c | | |
| | | |
| | | control logi | | |
| | | |
| | | |
| | | S - Air set clutch / light spring set brake with air assist ~a| = A - Air set clutch / medium spring set brake Jj| = B - Air set clutch / heavy spring set brake JM = C - Air set clutch / no brake d = SA - Air set clutch / medium spring set brake with air assist e = SCP - Self centered piston / air set | | |
| | | f = SA/ACP - Air centered piston/air set clutch / Medium spring set brake with air assist g = B/ACP - Air centered piston / Air set clutch / Heavy spring set brake p = P - Air set clutch / Air set brake (without springs) j = A/ACP - Air centered piston / Air set clutch / Medium spring set brake | | |
| | | NOTES: * When Piggyback Mounting is required both input and output modules must be specified Piggyback. The Motor Frame Size must also be specified to predrill and tap the motor mounting base. ** Output Housing is machined to accept an Encoder. See Section 7 for ordering the actual Encoder. *** Not available on C-Face Input. | | |
| | | |
| | | |
| | | |
| | | 2.17 | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |