Specifications
Operating Range
0 °C to 50 °C (32 °F to 122 °F); 0 %RH to 100 %RH
Calibrated Temperature Accuracy ("H" Model)
± 0.125 °C from 16 °C to 24 °C (± 0.225 °F from 60.8 °F to 75.2 °F)
Calibrated temperature Accuracy ("S" Model)
± 0.25 °C from 15 °C to 35 °C (± 0.45 °F from 59 °F to 95 °F)
Calibrated RH Accuracy
("H" Model)
± 1.5 %RH from 20 %RH to 70 %RH
Calibrated RH Accuracy
("S" Model)
± 2 %RH from 20 %RH to 70 %RH
Expected Extrapolated
Performance
(Uncertified)
± 0.5 °C (± 0.9 °F) outside calibrated range ± 3 %RH outside calibrated range
Delta Temperature Accuracy
± 0.025 °C for ± 1 ° changes within 15 °C to 35 °C (± 0.045 °F for ± 1 ° changes within 59 °F to 95 °F)
Temperature Resolution
User selectable up to 0.001 °C/°F on front-panel display (0.01° recorded)
Delta Humidity Accuracy
± 1.0 %RH for ± 5 % changes within 20 %RH to 70 %RH
RH Resolution
User selectable up to 0.01 % on front-panel display (0.1 % recorded)
Inputs
Up to two sensors, measure temperature and relative humidity, detachable, cable-extendable, interchangeable, self-contained calibrations, may be as­signed unique 16-character identifications
Display
240 x 128 graphics monochrome LCD, displays password-protected tempera­ture/humidity data graphically, numerically, and statistically (one or both channels); 16 pre-defined, user-changeable screen setups
Memory
400,000 typical individual date/time-stamped readings
Alarms
Password-protected visual, audible, and external alarms for temperature, temperature rate, RH, RH rate, and fault conditions
Alarm Port Output
2.5 mm two-conductor subminiature plug, 0 V normal, 11 to 12 V active, sources up to 20 mA
Connectivity
Ethernet, RS-232, RF (optional)
Ethernet
RJ45 jack, 10 Base-T or 100 Base-TX; static or dynamic (DHCP client) IP ad­dress assignment
Web Page
Embedded web page interface features: instrument identification, measure­ments, password-protected terminal page; can be disabled
Wireless Option
Requires wireless modem. 802.15.4 (underlies Zigbee), 2.4 GHz frequency, 1 mW transmit power, 30 m (100 ft) typical unobstructed range; can be dis­abled
Mounting
Wall mounted (hardware included) or set on a bench top
Power
12 V dc from external 100 to 240 V dc power supply
Battery Backup
Standard 9 V battery enables continued measuring during power disruptions
Size (DewK) (HxWxD)
125 mm x 211 mm x 51 mm (4.9 x 8.3 x 2.0 in)
Size (Sensors) (LxDia)
79 mm x 19 mm (3.1 x 0.75 in)
Weight
0.7 kg (1.5 lb)
Calibration
Certificate of NIST-traceable NVLAP accredited temperature and humidity cali­bration included; As Found and As Left data supplied at three temperature points and three humidity points each at 20 °C (68 °F); Complies with NCSL/ISO/IEC 17025:2000 and ANSI/NCSL Z540-1-1994
Log Ware III (Optional Software)
Requirements include: Microsoft® Windows® 2000 (SP4) or XP (SP2) operat­ing system, IBM compatible Intel Pentium® IV 1 GHz PC processor or better, 512 Mb RAM (1Gb or more recommended), 200 Mb HDD space for installation (additional free space recommended for data storage), CD-ROM drive for installation
Fluke. Keeping your world up and running.™
Fluke Corporation Hart Scientific Division
799 E Utah Valley Drive
American Fork, UT 84003
Tel: 801.763.1600
Fax: 801.763.1010
E-mail: info@hartscientific.com
For more information call: Europe/Africa/Middle East: Fluke Europe B.V. Hart Scientific Division P.O. Box 1186, 5602 BD Eindhoven, The Netherlands
Tel: (31 40) 2 675 200 Fax: (31 40) 2 675 222
Canada
Tel: 1-800-36-FLUKE or
905.890.7600 Fax: 905.890.6866
Other countries
Tel: 801.763.1600 Fax: 801.763.1010
Web access: www.hartscientific.com
© 2006 Fluke Corporation, Hart Scientific Division. All rights reserved. Specifications subject to change without notice. 10/2006 2728033 D-US-N Rev B
4 Fluke Corporation, Hart Scientific Division 1620A "DewK" Thermo-Hygrometer

pageCatalog pdf di En 2012-05-22-29