| | | Really cold baths | | |
| | | |
| | | Ordering Information | | |
| | | |
| | | | | |
| | | 7060 7080 7100 | | Standard Bath, -60 °C to 110 °C Standard Bath, -80 °C to 110 °C Standard Bath,-100 °C to
| |
| | | |
| | | 110 °C 2001-7060 Automation Package for 7060 2001-7080 Automation Package for 7080 2001-7100 Automation Package for 7100 | | |
| | | |
| | | 2001-IEEE | | Add for IEEE-488 (requires Auto-
| |
| | | |
| | | mation Package)
| |
| | | |
| | | 2010 | | Access Cover, 127 x 254 mm
| |
| | | |
| | | (5 x 10 in), Lexan | |
| | | |
| | | 2007 | | Access Cover, 127 x 254 mm
| |
| | | |
| | | (5x 10 in), Stainless Steel 2016-7060 Fluid Level Adapter, 7060 2016-7080 Fluid Level Adapter, 7080 2019-7100 Fluid Level Adapter, 7100 | | |
| | | |
| | | 2069 | | 8X Magnifier Scope, with mounts | |
| | | | |
| | | |
| | | 8892510660 | |
| | | |
| | | Self-contained refrigeration—no LN2 or chiller required Temperatures as low as -100 °C in real metrology baths Best stability and uniformity available at -60 °C and below Large working areas for increased throughput | | |
| | | The 2016 fluid level adapter circulates fluid to the top of the bath access to give as much immersion as possible for LIG thermometers. | | |
| | | |
| | | |
| | | Do you need a bath that chills below -40 °C to temperatures as low as -60 °C or even -100 °C? Would you like a bath that reaches those temperatures without using any external coolants? Hart has a variety of baths that meet these temperature requirements and give you the best stability in the industry. These baths are completely self-contained. They require no auxiliary cooling fluids or devices to achieve their set-point temperatures. Using Hart's unique "heat-port" design, stability at -100 °C is ± 0.008 °C. No other company makes a bath that can match a Hart bath's performance, and Hart baths are backed by our guarantee that if they don't perform exactly the way we say they will, we'll | | |
| | | take them back. No arguments. No ifs, ands, or buts. Automate each of these baths with an interface package and Hart's 9930 Interface-it software. If you want to completely automate the entire calibration process, see the description of Hart's MET/TEMP II software package on page 97. Forget commodity-like utility baths! They're not designed for high performance calibration needs. And be careful of companies that advertise performance specifications they don't meet. It's easy to write down numbers; it's more difficult to meet them with an instrument. Remember, if our baths don't perform the way we say they will, just send them back. Our equipment won't disappoint you. | | |
| | | |
| | | |
| | | 114 Baths | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |