clamped between two flanges of the existing tu-bes. The Flash Mixer is used as a complete in-bet- ween flange mixer. The latter has the advantage of being removable in radial direction without any need of disassembling the tubes.
Dichte = 1000 kgmViskosität = 1 mPas -3 CSE-B Mixer CSE-F Mixer Slide-in mixer Fig. 3 Aquamix DN100 / PN10, material 316 L Mixing performance and pressure drop The mixing performances of the Aquamix and the Flash Mixer are based on two contrarily rotating vortexes. These vortexes stretch over the whole cross sectional area thus ensuring the excellent, stable and well controlled mixing efficiency. The ho- mogeneity is normally expressed by the coefficient of the standard deviation. Acoefficient of variation of < 0.03 is assessed as homogeneous. Full per- formance of the mixer is achieved at flow veloci- ties of > 0.3 ms Aquamix Flash Mixer 10 100 500 50 dp(mbar) 0.512 1.5 34 w (ms )
-1 Fig. 5 Pressure drop for Fluitec industrial mixers (water) The remarkable low pressure drops of the newlydeveloped Aquamix and of the Flash Mix allow for the first time the application of static mixers at li- quid velocities of up to 4 ms
-1 . In the Aquamix, the additive isdosed before the flange connection, while the do- sing device of the Flash Mixer can be integrated directly in the in-between flange. For additive con- centrations of lower than 1%, the dosing nozzle must be mounted concentric before the mixing ele- ment. Otherwise a normal T-piece can be applied in a distance of 2 to 5D (D=diameters of the tube)
-1 .
Reynolds-Number > 15000Concentration X = 0.01-0.05 Sample size 0.033 DRatio of viscosity <10 X CSE-F Mixer Slide-in mixer CSE-B Mixer 0.050.55 AquamixFlash Mixer 0.010.1110 1234567891011120 Relative Length L/D (-) Fig. 4 Coefficient of variation in function of the relative mixing length before the mixing element. Fig. 4 shows the coef-ficient of variation in function of the relative mixing length. The table indicates that measuring points such as temperature probes or pH probes must be installed at a minimum distance of 10 D to the mixing element. Abb. 6 Fluitec Flash Mischer DN65 /PN10-PN64