PSS II Dimensional Data in inches
Shaft &
Seal Size ^
+0.001" -0.002"
B C D E E F G H J Min Min Max Min Max Min Max
K
1.500 2.12 to 2.50 2.75 1.625 2.25 to 2.62 2.88 1.750 2.38 to 2.75 3.00
5.25 0.500 5.50 0.500 5.41 0.500
3.50 4.33 3.62 4.75 3.75 4.36
2.50 2.12 1.71 2.50 2.12 1.71 2.50 2.12 1.71
2.31 0.33 2.31 0.33 2.31 0.33
1.875 2.50 to 2.88 3.12 2.000 2.62 to 3.00 3.25 2.125 2.75 to 3.25 3.50
5.53 0.500 3.88 4.67 2.50 2.12 1.71 2.31 0.33 5.75 0.500 4.03 5.06 2.50 2.12 1.71 2.31 0.33 5.69 0.625 4.44 5.38 2.72 2.34 1.84 2.53 0.39
2.250 2.88 to 3.38 3.62 2.375 3.00 to 3.50 3.75 2.500 3.12 to 3.75 3.88
5.81 0.625 5.94 0.625 6.88 0.625
4.56 5.64 4.69 5.06 5.00 6.20
2.72 2.34 1.84 2.72 2.34 1.84 2.72 2.34 1.84
2.53 0.39 2.53 0.39 2.53 0.39
Stull iüfl £ Sei! Sir:
2.625 3.25 to 3.75 4.00 2.750 3.38 to 3.88 4.12 2.875 3.50 to 4.00 4.25
6.19 0.625 4.94 6.00 2.72 2.34 1.84 2.53 0.39 6.75 0.625 5.06 6.17 2.72 2.34 1.84 2.53 0.39 6.44 0.625 5.19 5.94 2.72 2.34 1.84 2.53 0.39
3.000 3.62 to 4.12 4.38 3.125 3.75 to 4.25 4.50 3.250 3.88 to 4.38 4.62
7.62 0.750 7.06 0.750 7.19 0.750
5.56 6.63 5.56 6.44 5.69 6.63
2.72 2.34 1.84 2.72 2.34 1.84 2.72 2.34 1.84
2.53 0.39 2.53 0.39 2.53 0.39
3.375 4.00 to 4.50 4.75 3.500 4.25 to 5.00 5.25 3.625 4.38 to 5.13 5.38
7.31 0.750 8.50 0.750 8.00 0.750
5.81 6.69 6.38 7.45 6.50 7.37
2.72 2.34 1.84 3.06 2.69 2.19 3.06 2.69 2.19
2.53 0.39 2.88 0.51 2.88 0.51
3.750 4.50 to 5.25 5.50 3.875 4.63 to 5.38 5.63 4.000 4.75 to 5.50 5.75
8.75 0.750 6.63 7.83 3.06 2.69 2.19 2.88 0.51 8.25 0.750 6.75 7.63 3.06 2.69 2.19 2.88 0.51 9.00 0.875 7.00 7.92 3.06 2.69 2.19 2.88 0.51
4.125 4.88 to 5.63 5.88 4.250 5.00 to 5.75 6.00 4.375 5.13 to 5.88 6.13
8.88 0.875 7.13 8.13 3.06 2.69 2.19 2.88 0.53 9.00 0.875 7.25 8.25 3.06 2.69 2.19 2.88 0.57 9.13 0.875 7.38 8.38 3.06 2.69 2.19 2.88 0.60
4.500 5.25 to 6.00 6.25 9.25 0.875 7.50 8.50 3.06 2.69 2.19 2.88 0.64
4.625 5.38 to 6.13 6.38 9.38 0.875 7.63 8.63 3.06 2.69 2.19 2.88 0.68
4.750 5.50 to 6.25 6.50 9.26 0.875 7.75 8.51 3.06 2.69 2.19 2.88 0.72
4.875 5.63 to 6.38 6.63 9.63 0.875 7.88 8.88 3.06 2.69 2.19 2.88 0.75
5.000 5.75 to 7.00 7.25 10.65 0.875 8.50 10.00 3.06 2.69 2.19 2.88 0.79
5.125 5.88 to 7.13 7.38 10.38 0.875 8.63 9.63 3.06 2.69 2.19 2.88 0.83
5.250 6.00 to 7.25 7.50 10.50 0.875 8.75 9.75 3.06 2.69 2.19 2.88 0.87
5.375 6.13 to 7.38 7.63 10.63 0.875 8.88 9.88 3.06 2.69 2.19 2.88 0.90
5.500 6.25 to 7.50 7.75 11.50 0.875 9.00 10.75 3.06 2.69 2.19 2.88 0.94
5.625 6.38 to 7.63 7.88 10.88 0.875 9.13 10.13 5.750 6.50 to 7.75 8.00 11.00 0.875 9.25 10.25 5.875 6.63 to 7.88 8.13 11.13 0.875 9.38 10.38 6.000 6.75 to 8.00 8.25 11.25 0.875 9.50 11.25 Othersizes available on request. Contact Flowserve Engineering.
The Split Flow Reducer is the perfect accessory for the PSS II
The Split Flow Reducer is an engineered, close clearance device which lowers seal waterflush (API Plan 32) requirements when used with the PSS II. Split axially for easy installation, the Split Flow Reducer is constructed of glass filled PTFE for corrosion and abrasion resistance.
FSD125eng REV 03-07 Printed in USA
3.06 2.69 2.19
3.06 2.69 2.19
3.06 2.69 2.19
3.06 2.69 2.19
2.88 0.98
2.88 1.02
2.88 1.05
2.88 1.09
USA and Canada
Kalamazoo, Michigan USA Telephone: 1 269 381 2650 Telefax: 1 269 382 8726
Europe, Middle East, Africa
Roosendaal, The Netherlands Telephone: 31 165 581400 Telefax: 31 165 552622
Asia Pacific
Singapore
Telephone: 65 6544 6800 Telefax: 65 6214 0541
Latin America
Mexico City
Telephone: 52 55 5567 7170 Telefax: 52 55 5567 4224
To find your local Flowserve representative
and find out more about Flowserve Corporation visit www.flowserve.com
Flowserve Corporation has established industry leadership In the design and manufacture of its products. When properly selected, this Flowserve product Is designed to perform Its intended function safely during its useful life.However, the purchaser oruserof Flowserve products should be aware that Flowserve products might be used In numerous applications underawlde variety of Industrialservice conditions. Although Flowserve can provide general guidelines, it cannot provide speciHc dataand warnings forallpossibleappllcations.Thepurchaser/usermusttherefore assume the ultimate responsibility forthe proper sizing and selection. Installation, operation, and maintenance of Flowserve products.The purchaser/user should read and understand the Installation Instructions Included with the product, and train Its employees and contractors In the safe use of Flowserve products In connection with the specific application.
While the information and specifications contained In this literature are believed to be accurate, they are supplied for Informative purposes only and should not be considered certified orasaguaranteeof satisfactory results by reliance thereon.Nothlng contained herein Is to be construed as awarranty orguarantee. express or Implied, regarding any matterwith respect to this product.Because Flowserve is continually Improving and upgrading its product design, the specifications, dimensions and Information contained herein are subjectto change without notice.Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at anyone of Its worldwide operations or offices.
© 200/ Flowserve Corporation