Liquid ring compressors LOH 20103, LOH 20107
8Pages

{{requestButtons}}

Catalog excerpts

Liquid ring compressors LOH 20103, LOH 20107 - 1

Liquid ring compressors LOH 20103, LOH 20107 VACUUM TECHNOLOGY KPH K 2 133.72110.53.01 E 03/2002 Compression pressures: 0,2 to 1 bar Suction volume flow: 18 to 51 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors of simple and robust construction. They have the following important features: Handling of nearly all gases and vapours non-polluting due to nearly isothermal compression oil-free, as no lubrication in the working chamber additional liquid can be handled with the gas flow easy in maintenance and reliable operation low noise and nearly free of vibrations wide choice of material, therefore applicable nearly everywhere no metallic contact of the rotating parts The Sterling SIHI liquid ring compressors LOH 20103 and LOH 20107 are single-stage compressors. They can be applied without modification as vacuum pump up to a suction pressure of 150 mbar see catalogue part LI). APPLICATION Handling and compressing of dry and humid gases; entrained liquid can be handled during normal duty. The compressors are applied in all fields where a compression over pressure of up to 1 bar has to be created by robust compressors and only a small increase in temperature is admissible during compression. Fields of application are e.g.: - the plastics industry, for the recovery of process gases as vinyl chloride - the petrochemical industry, for the compression of combustible gases as gasoline vapours or hydrogen - transport of gases in general, e.g. to a reactor NOTE During operation the compressor must continuously be supplied with service liquid, normally water, in order to eliminate the heat resulting from the gas compression and in order to replenish the liquid ring, because part of the liquid is leaving the compressor together with the gas. This liquid can be separated from the gas in a pressure liquid separator ( see catalogue part accessories). It is possible to reuse the service liquid. The direction of rotation is clockwise, when looking from the drive on the pump. GENERAL TECHNICAL DATA Pump type unit LOH 20103 LOH 20107 Speed 50 Hz 60 Hz rpm 2800 3400 2800 3400 Max. compression over pressure bar 1 Hydraulic test (over pressure) bar 3 Moment of inertial of the rotating pump parts and the water filling kg . m² 0,0033 0,005 Sound pressure level of measuring area dB (A) 70 71 70 71 Min. pulley diameter permissible in case of V-belt drive mm 80 90 Max. gas temperature dry saturated °C °C 200 100 Service liquid max. admissible temperature max. viscosity max. density °C mm²/s kg/m³ 80 90 1200 volume up to shaft level litre 0,9 1,0 The combination of several limiting values is not admissible.

Open the catalog to page 1
Liquid ring compressors LOH 20103, LOH 20107 - 2

2 Material design MATERIAL DESIGN Item. COMPONENTS 01 02 42 0001, 0002 Casing 0.6025 1.4408 0010, 0011 Intermediate piece 0.6025 1.4408 0030 Vane wheel impeller RG 9 1.4027.05 1.4517 0035 Central body 1.0570 1.4581 0200 Shaft 1.4021 1.4401 0500, 0600 Mechanical seal Cr-steel / carbon / Perbunan Cr Ni Mo-steel / carbon / Viton Sectional drawing LOH 20103, LOH 20107

Open the catalog to page 2
Liquid ring compressors LOH 20103, LOH 20107 - 3

3 Suction volume flow and power absorption LOH 20103 5 10 15 20 25 30 0 0,2 0,4 0,6 0,8 1 1,2 compression over pressure suction volume flow 2800 rpm LOH 20103 3400 rpm m³/h bar 0 0,4 0,8 1,2 1,6 0 0,2 0,4 0,6 0,8 1 1,2 compression over pressure power absorption 2800 rpm LOH 20103 3400 rpm kW bar The values indicated for volume flow and power absorption are valid for compression of dry air at 20°C from atmospheric pressure (1013 mbar) to the respective compression pressure with water at 20°C as service liquid. Tolerance of the curve values is 10 %. The compression pressure in bar is...

Open the catalog to page 3
Liquid ring compressors LOH 20103, LOH 20107 - 4

4 Suction volume flow and power absorption LOH 20107 10 20 30 40 50 60 0 0,2 0,4 0,6 0,8 1 1,2 compression over pressure suction volume flow 2800 rpm LOH 20107 3400 rpm bar m³/h 0 0,5 1 1,5 2 2,5 3 0 0,2 0,4 0,6 0,8 1 1,2 compression over pressure power absorption 2800 rpm LOH 20107 3400 rpm bar kW The values indicated for volume flow and power absorption are valid for compression of dry air at 20°C from atmospheric pressure (1013 mbar) to the respective compression pressure with water at 20°C as service liquid. Tolerance of the curve values is 10 %. The compression pressure in bar is...

Open the catalog to page 4
Liquid ring compressors LOH 20103, LOH 20107 - 5

5 Dimensional drawing LOH 20103, LOH 20107 oval flange to DIN 2558 PN 6 weight a m 1 m 2 o 3 abt. kg LOH 20103 114 260 230 299 20 LOH 20107 149 295 265 334 21 N 1 = gas inlet G 1 ¼ N 2 = gas outlet G 1 ¼ uB = connection for service liquid G 3/8 ue = drainage (screwed plug) G ¼

Open the catalog to page 5
Liquid ring compressors LOH 20103, LOH 20107 - 6

6 Arrangement drawing LOH 20103, LOH 20107 with pressure liquid separator * dimensions dependent on the motor make N 1 = gas inlet G 1 ¼ N 2 = gas outlet DN 65 uA = liquid drain DN 15 uA1 = liquid drain DN 15 ub = connection for safety valve G ¾ ue1 = drain connection G ½ uF = connection for fresh liquid 18 uFl = connection for liquid level indicator G ½ electric motor 50 Hz weight size kW b 2 c d e 1 e 2 h h 5 l l 1 o 1 * o 2 * t 1 v w 1 abt. kg IP 55 EEx e ll T3 80 a 0,75 - 274 899 LOH 20103 80 b 1,1 - 317 20 15 350 285 35 235 570 212 165 110 608 44 80 a - 0,75 272 897 80 b - 1,1 90 S 1,5...

Open the catalog to page 6
Liquid ring compressors LOH 20103, LOH 20107 - 7

7 Fresh water requirement in [m³/h] dependent on compression pressure, speed, mode of operation and difference in temperature compression pressure in bar 0,2 0,4 0,8 1 pump speed KB KB KB KB [rpm] difference in temperature [°C] FB difference in temperature [°C] FB difference in temperature [°C] FB difference in temperature [°C] FB 30 20 10 5 30 20 10 5 30 20 10 5 30 20 10 5 LOH 20103 2800 0,01 0,02 0,03 0,05 0,15 0,02 0,02 0,04 0,07 0,21 0,02 0,03 0,06 0,10 0,35 - - - - - 3400 0,02 0,03 0,05 0,07 0,02 0,03 0,06 0,09 0,03 0,05 0,08 0,13 0,04 0,06 0,10 0,16 0,4 LOH 20107 2800 0,02 0,03 0,05...

Open the catalog to page 7
Liquid ring compressors LOH 20103, LOH 20107 - 8

8 Accessories Recommended accessories LOH 20103 LOH 20107 Pressure liquid separator type weight XBd 0413 28 kg material design 130 / St-galvanized 172 / 1.4571 SIHI part No. 35 000 298 35 000 299 service liquid line material design 072 / St 37-0 172 / 1.4571 SIHI part No. 35 018 092 35 003 086 35 018 093 35 003 087 discharge line material design 072 / St 37-0 172 / 1.4571 SIHI part No. 35 003 167 35 003 168 Liquid discharge trap type / weight XUk 1602 / 11 kg material design 762 / GG20+1.4541 SIHI part No. 43 014 792 hanging gas line material design 072 / St 37-0 SIHI part No. upon request...

Open the catalog to page 8