Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C
12Pages

{{requestButtons}}

Catalog excerpts

Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 1

SIHIpr/me- Side Channel Pumps Self-priming, segmental type TECHICAL DATA Delivery head: Casing pressure: Shaft sealing: Flange connections: max. 180 °C for high temperature design (higher temperatures on request) mechanical seal (when seen from the drive end) Protection classification: The Sterling SIHI AEH-X pump is a self-priming side channel pump capable of handling gas along with the medium and operates at a The AEH-X pumps, as per DIN EN 734, are used for problem-free pumping of clean liquids at unfavourable suction side conditions. (condensates, corrosive liquids, ...). Different material possibilities with uniform dimensions and performance characteristics as well as the standard exchangeable components are used for the construction. The AEH-X pumps are particularly recommendable in a wide application range in many • Chemical industry, • Petro-Chemical industry, • Pharmaceutical industry, • Food industry, The pumps of the SIHIp"me range are side channel pumps having segmental type construction. The program comprises, currently, 3 sizes each with 1-8 stages. The existing material design allows an optimum rating for the respectively desired performance range and the pumping medium. The applied hydraulic components are from our modular side channel system (interchangeability of parts). Casing pressure Pressure stages for temperature as per DIN EN 1333. Please observe Technical rules and safety regulations: Casing pressure = inlet pressure + delivery head at minimum pump Suction and discharge branch point radially upwards. Flanges in accordance with DIN EN 1092-2 / PN 40. Flange design as per DIN 2512 with groove or drilled according to ANSI 150 or 300 lbs is basically possible. Either by a ball bearing and a liquid surrounded sleeve bearing (design A) or by two ball bearings (design B). The ball bearings are according to DIN 625 and greased for life. Rotation direction Clockwise, when looking at the pump from the drive end. Shaft sealing The shaft is sealed by a mechanical seal according to DIN EN 12756, with quench connection. The shaft sealing is also available in a design suitable for heating or cooling of the mechanical seal and a double mechanical seal (back- to-back as well as tandem) design is possible on request. PUMP TECHNOLOGY AEH-X PII/11

Open the catalog to page 1
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 2

Material design * Bearing bush in Antimony Carbon is only used in high temperature design. Casing seal The casing sealing is done by o-ring gaskets compatible with the handled medium. By electric motor, type of construction IM B3. According to the area of usage, we can supply motors of any kind of protection (EExe, EExd). General comments Side Channel pumps with the same hydraulic construction are manufactured in series as: AOHA Low duty pump with oval flanges, PN 10 AKH-X Medium duty pump, PN 25 CEBA Vertical pump, PN 25 with magnetic coupling CEH-X High duty pump combined with a low NPSH...

Open the catalog to page 2
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 3

Sectional drawing and parts list Mechanical seal 1090 First suction intermediate 1140 Side channel intermediate 1141 Last discharge intermediate 1600 Cover plate (design A) Cooled mechanical seal 2350 Vane wheel impeller 3600 Open bearing cover 3610 Closed bearing cover (design B) 4410 Mechanical seal casing 5451 Bearing bush (design A)

Open the catalog to page 3
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 4

Operating principle The AEH-X pump is a side channel system, self priming, and segmental type. A side channel stage consists of: • A suction intermediate part (1 ), • A discharge intermediate part including the side • A vane wheel impeller located between the 2 The fluid entrance goes through the suction hole (4). The turning of the vane wheel impeller creates an under pressure at the beginning of the side channel and the liquid (with or without gas) is drawn in. The pressure generating is obtained by the repetitive re-entering of the liquid in the side channel (5). The liquid goes then to...

Open the catalog to page 4
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 5

Performance range General conditions Liquid: Water Atmospheric pressure: 1013 mbar Characteristic tolerances The Side Channel pumps are not submitted to any normalized test tolerances. Here under are our acceptance values: Capacity ± 9% - Delivery head ± 7% - Power + 10%. Measuring standard

Open the catalog to page 5
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 6

Dimension chart and pump set drawing * Design A (1 ball bearing, 1 sleeve bearing) The weight of the pump will be approximately 6% higher when using stainless steel. General: Values are valid for water p = 1 kg/dm3 and u = 1 cSt. Design tolerances: Capacity! 9% - Delivery head ± 7% - Power + 10%. Notes: 1) For EExe II T3 motors. 2) For every pump set in ATEX area. 3) Dimensions are depending on the used motor trade mark (indicated values correspond to design B).

Open the catalog to page 6
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 7

Performance curves

Open the catalog to page 7
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 8

Dimension chart and pump set drawing * Design A (1 ball bearing, 1 sleeve bearing) The weight of the pump will be approximately 6% higher when using stainless steel. General: Values are valid for water p = 1 kg/dm3 and u = 1 cSt. Design tolerances: Capacity! 9% - Delivery head ± 7% - Power + 10%. Notes: 1) For EExe II T3 motors. 2) For every pump set in ATEX area. 3) Dimensions are depending on the used motor trade mark.

Open the catalog to page 8
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 9

Performance curves

Open the catalog to page 9
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 10

Dimension chart and pump set drawing * Design A (1 ball bearing, 1 sleeve bearing) The weight of the pump will be approximately 6% higher when using stainless steel. General: Values are valid for water p = 1 kg/dm3 and u = 1 cSt. Design tolerances: Capacity! 9% - Delivery head ± 7% - Power + 10%. Notes: 1) For EExe II T3 motors. 2) For every pump set in ATEX area. 3) Dimensions are depending on the used motor trade mark.

Open the catalog to page 10
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 11

Performance curves

Open the catalog to page 11
Catalogue - Series AEH-X, 7.5 m³/h, 312 m, 180 °C - 12

Sterling SIHI GmbH

Open the catalog to page 12

All Flowserve SIHI Pumps catalogs and technical brochures

  1. PL 325 M

    14 Pages

  2. LPG Solutions

    12 Pages