| | | ght to nt | | |
| | | _ stra the po | | |
| | | |
| | | |
| | | The Fixturlaser® VSP* Contents*: 1 Robust aluminum case 1 Laser transmitter 1 Detector unit 1 Display unit with software the laser transmitter 1 Set of extendable fixtures for the detector unit | | |
| | | 1 Cable 1 PC software 1 Manual 1 Printer Accessories*: • AC adapter • Leatherette; Protection cover for the display unit | | |
| | | CAUTION | | |
| | | |
| | | m KB | | |
| | | |
| | | |
| | | |
| | | The procedure for measuring plumbness of a vertical turbine shaft is a straightforward operation, very similar to traditional methods with wires and a sound micrometer. The laser transmitter is positioned at the lower end of the shaft and measurement readings are taken with a detector unit probing against the shaft surface. The first reading is taken at the top, and subsequent readings move down the shaft towards the transmitter. The detector is returned to the top position to verify accuracy. Four sets of these readings are taken, one in each quadrant (i.e., north, south, east and west).The four measurement results are stored in the display unit, and then transferred to a PC for final calculation. The measurement is a straightness measurement in one axis, but the two-axes detector provides for increased accuracy while it guides the operator in positioning the detector correctly on the shaft curvature. | | |
| | | Detector unit; attached with fixturing to the shaft with magnetic base. A sliding measurement probe provides for precise measurement readings. | | |
| | | |
| | | | | |
| | | |
| | | Laser transmitter with precision calibrated spirit levels. Robust and lightweight fixturing and coordinate table in aluminum allow for easy setup. Four magnet bases provide for firm attachment to the shaft. | | |
| | | |
| | | |
| | | | | | | | | | Technical specification* | | | | Measuring distance | 81 feet | | | | Displayed measurement result resolution 0,0001" | | | | Operating temperature range | 32- 104°F | | | | Detector size | 20x20 mm | | | | Power supply | Standard batteries, 4 "D" cells | | | | Operating time | Depending on operation cycle 10 - 20 hrs | | | | Weight complete system | 24 pounds | | | | * Specifications are subject to changes without notice. | | | | Our representatives are all engineers and techni- | our customers. It includes telephone assistance, hardware | | | | cians with special knowledge and training in the | repairs and software updates, as well as training and con- | | | | latest measurement and alignment techniques. An | sultation regarding measurement applications. | | | | extensive service program is provided to support all | | | | | FIXTURLASER AB | | | | | Box 7 | | | | | SE-431 21 Molndal | | | | | Sweden | | | | | Phone:+ 46 31 706 28 00 | | | | | Fax: + 46 31 706 28 50 | | | | | Email: ¡nfo@fixturlaser.se | | | | | Web: www.fixturlaser.com | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | |