F IXTURLASER®Fast, easy and precise shaft alignment made really easyExigoThe Fixturlaser Exigo in short:Fast set-up, fast resultsIntuitive operationMeasurement resolu-tion down to 0,01mm Easy to learn, easy to use Live values during alignmentIntrinsically safe shaft alignment tool Bringing precision alignment into explosive hazardous areasThe Fixturlaser Exigo is an intrinsically safe (Ex) shaft alignment tool, especially designed for use in potentially explosive hazardous areas. It has been tested and certi- fied according to the latest ATEX standards in intrinsic safety zones generally found in industries such as the petrochemical, gas and pharmaceutical among others. The Fixturlaser Exigo can be supplied with a thermal printer for recording alignment activities. The easy-to-use, ergonomically designed dis-play fits right in your hand. Its intuitive design means you can step through an alignment as soon as you pick it up. The Fixturlaser Exigo has been designed to let you concentrate your skill and effort on performing precision alignments, not on figuring out how to use the tool. • Intrinsically safe classification EEx ib IIC T4, ATEX code: II 2 G • Printer facilitates recording of alignment activities • Maximum distance of 1 m (3 ft) between the measuring units makes it suitable for aligning most applications • Display unit provides real time values during the alignment process making rechecking alignment unnecessary • User-friendly display unit with only five buttons |
|