Ol North American
Manufacturing Company
ASPIRATOR AIR/GAS MIXERS
Bulletin 3065
October 1991
3065 Aspirator Mixers use the energy of blower air passing through a venturi to entrain a proportional flow of gas at atmospheric (zero gauge) pressure. Btu input to nozzles fed by the 3065 thus can be controlled by a single manual or motorized air valve.
Proper air/gas ratio, set by adjusting the integral V-portt valve in the mixer, is maintained from high fire to low by an "atmospheric regulator" or "zero governor" (e.g., North American's 7218).
A definite relationship should be maintained between mixer orifice size and burner port size. Within limits, the mixer orifice size can be altered by exchanging displacement rods. Several rods are available for each size mixer--see Instruc­tions and Parts List 3065. Rod diameter, in 32nds of an inch, is stamped on the rod nut.
For coke oven, manufactured, and other gases corrosive to brass, specify 3065- -K Mixer with all iron parts.
Figure 1. Typical arrangement of 3065 Aspirator Mixer with burner, atmospheric regulator, and air valve.
TABLE 1. Capacities of 3065 Mixers with North American nozzles.
scfh air (for Btu/hr, multiply by 100)$
Required Air Pressure in osi for Natural Gas
Complete
North
2
1 4
6
8
10
12
14
16
Mixer Designation
American
Required Air Pressure in osi for Manufactured or Coke Oven Gas
Premix
2.3
I 5.7
I 6.8
9.1
11.4
13.7 1
16.00 1
18.3
Manufactured or
Natural
Burner
Mixture Pressure in inches of Water Column
Coke Oven Gas
Gas
Size
1
| 2.5
3
4
5
6
7
8
_
_
-01
130
210
220
260
290
320
340
360
3065-0-8
3065-0-7
-0-A
200
320
340
390
440
480
520
550
3065-0-7
3065-0-5
-0-B
250
400
430
500
560
610
660
710
3065-0-5
3065-0-0
-0-C
280
450
490
570
640
700
750
810
3065-1-11
3065-1-9
-1-A
350
560
600
700
790
860
920
990
3065-1-9
3065-1-6
-1-B
440
700
760
880
990
1 070
1 160
1 240
3065-2-13
3065-2-12
-2-A
560
880
960
1 120
1 260
1 370
1 480
1 580
3065-2-12
3065-2-10
-2-B
650
1 030
1 120
1 300
1 460
1 590
1 720
1 840
3065-1-20
3065-2-6
-2-C
780
1 230
1 340
1 560
1 750
1 910
2 060
2 190
3065-2-6
3065-2-0
-2-D
880
1 390
1 510
1 760
1 980
2 150
2 320
2 480
3065-3-14
3065-3-11
-3-A
980
1 550
1 690
1 960
2 200
2 390
2 590
2 760
3065-3-11
3065-3-6
-3-B
1 200
1 900
2 060
2 400
2 690
2 930
3 170
3 380
3065-4-18
3065-4-16
-4-A
1 500
2 380
2 580
3 000
3 360
3 660
3 960
4 240
3065-4-14
3065-4-10
-4-B
1 900
3 010
3 280
3 800
4 270
4 650
5 000
5 350
3065-4-12
3065-4-8
-4-C
2 050
3 240
3 530
4 100
4 610
5 000
5 400
5 800
3065-5-18
3065-5-14
-5-A
2 450
3 880
4 220
4 900
5 500
5 990
6 500
6 900
3065-5-13
3065-5-10
-5-B
2 900
4 600
5 000
5 800
6 500
7 100
7 650
8 200
3065-6-24
3065-6-20
-6-A
3 200
5 050
5 500
6 400
7 200
7 800
8 450
9 000
3065-6-18
3065-6-10
-6-B
3 850
6 100
6 600
7 700
8 650
9 400
10 200
10 800
3065-6-16
3065-6-0
-6-C
4 250
6 700
7 300
8 500
9 550
10 300
11 200
12 000
3065-7-38
3065-7-34
-7-A
4 750
7 500
8 500
9 500
10 600
11 600
12 600
13 400
3065-7-32
3065-7-26
-7-B
6 000
9 500
10 300
12 000
13 400
14 700
15 800
16 900
3065-7-26
3065-7-18
-7-C
7 050
11 100
12 100
14 100
15 800
17 200
18 600
19 800
3065-8-68
3065-8-64
-8-A
10 500
16 600
18 100
21 000
23 600
25 600
27 000
29 600
3065-8-60
3065-8-56
-8-B
13 000
20 600
22 400
26 000
29 300
31 800
34 400
36 800
3065-8-52
3065-8-36
-8-C
18 000
28 400
31 100
36 000
40 500
44 000
47 500
51 000
3065-8-28
3065-8-0
-8-D
21 500
34 000
37 000
43 000
48 400
52 500
56 500
60 500
3065-9-64
3065-9-56
-9
37 000
58 500
64 000
74 000
82 500
90 000
98 000
104 000
| 3065-9 Mixers have separate 1122-7-F Limiting Orifice Butterfly Valve for installation in the gas line upstream of the mixer. j Capacities with 100% combustion air through mixer and nozzle. Burners can be operated with "rich" mixture if secondary air is available in vicinity of nozzle, which increases Btu/hr capacities.