Instruction Manual

GX 3-way Control Valve and Actuator System - 14722 GX 3-Way Valve and Actuator

November 2008

Table 1. Fisher GX 3-Way Valve Specifications Specifications EN ASME
Valve Body Sizes DN 25, 40, 50, 80, 100 NPS 1, 1-1/2, 2, 3, 4 Pressure Rating PN 10 / 16 / 25 / 40 per EN 1092-1 CL150 / 300 per ASME B16.34 End Connections Flanged raised face per EN1092-1 Flanged raised face per ASME B16.5 1.0619 steel ASME SA216 WCC steel Valve Body Materials 1.4409 stainless steel ASME SA351 CF3M stainless steel Bonnet Materials 1.4409 stainless steel / CoCr-A ASME SA351 CF3M SST / CoCr-A Face-to-Face Dimensions ISA S75.03 Shutoff per IEC 60534-4 and ANSI/FCI 70-2 Metal seat - Class IV (standard) Flow Direction Converging and Diverging
Type Plug Style Type
Trim Style Side-Port Common All sizes Unbalanced Port-Guided Bottom-Port Common All sizes

Do not expose this product toservice conditions or variables otherthan those for which the product was intended.

Balanced Cage-Guided

Valve Installation

If you are not sure whatthese conditions are you shouldcontact your Emerson Process Management sales office for morecomplete specifications. Provide theproduct serial number (shown on the nameplate, figure 2) and all other pertinent information.

WARNING

Always wear protective gloves,clothing, and eyewear whenperforming any installation operations to avoid personal injury.Personal injury or equipment damagecaused by sudden release of pressureor bursting of pressure retaining partsmight result if service conditions exceed those for which the productwas intended. To avoid injury ordamage, provide a relief valve for over pressure protection as required bygovernment or accepted industrycodes and good engineering practices.Check with your process or safetyengineer for any additional measures that must be taken to protect againstprocess media.If installing into an existingapplication, also refer to the WARNINGat the beginning of the Maintenance section in this instruction manual.

WARNING

If you move or work on an actuatorinstalled on a valve with loadingpressure applied, keep your hands and tools away from the stem travel path toavoid personal injury. Be especiallycareful when removing the stem connector to release all loading on theactuator stem whether it be from airpressure on the diaphragm or compression in the actuator springs.Likewise take similar care whenadjusting or removing any optional travel stop. Refer to the relevantactuator Maintenance Instructions.If hoisting the valve take care toprevent people from being injured incase the hoist or rigging slips. Be sure to use adequately sized hoists andchains or slings to handle the valve.

CAUTION

This valve is intended for a specific range of pressures, temperatures and other application specifications.Applying different pressure and temperatures to the valve could resultin parts damage, malfunction of thecontrol valve or loss of control of the process.

2