See other catalogues for
FISHER
You may also be interested in
Text version of the page
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | |
| | | | | |
| | | | | |
| | | |
| | | |
| | | Table 6. VALVE DIMENSIONS | | |
| | | |
| | | | | | | | | | | | | | | | VALVE SIZE, NPS | A - VALVE BODY | B- BONNET | E | | | | in | DN | in | mm | in | mm | in | mm | | | | 1/2 & 3/4 | 15 & 20 | 3.5 | 89 | 3.1 | 78 | 1.0 | 25 | | | | 1 | 25 | 4.3 | 109 | 3.3 | 83 | 1.3 | 33 | | | | 1-1/2 | 40 | 5.3 | 135 | 3.9 | 98 | 1.9 | 48 | | | | 2 | 50 | 6.6 | 168 | 4.1 | 104 | 2.3 | 58 | | | | | | | | | | | | | | | |
| | | |
| | | Table 8. ACTUATOR WEIGHTS | | |
| | | Table 7. VALVE ASSEMBLY WEIGHTS | | |
| | | |
| | | |
| | | | | | | | | | | ACTUATOR TYPE | WEIGHTS | | | | lbs | kg | | | | 32 | 10 | 4.5 | | | | 54 | 25 | 11.3 | | | | 70 | 34 | 15.4 | | | | MV1020* | 22 | 10 | | | | VA1020* | 30 | 13.6 | | | | NV24-MFT* (non spring return) | 3.3 | 1.5 | | | | NVF24-MFT or NVF24-MFT-E* (spring return) | 4 | 1.8 | | | | | | | | | | |
| | | | | | | | | | | | VALVE SIZE, NPS | WEIGHTS | | | | in | DN | lbs | kg | | | | 1/2 | 15 | 3.5 | 1.6 | | | | 3/4 | 20 | 3.5 | 1.6 | | | | 1 | 25 | 5.0 | 2.3 | | | | 1-1/2 | 40 | 10.9 | 4.9 | | | | 2 | 50 | 19.7 | 8.9 | | | | | | | | | | | |
| | | |
| | | |
| | | *Electric Actuators, reference electric actuator bulletins for more details. | | |
| | | |
| | | FIELDVUE, Fisher and Baumann are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business division of Emerson Electric Co. Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. This product may be covered under one or more patents or under pending patent applications. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Neither Emerson, Emerson Process Management, Fisher, nor any of their affiliated entities assumes responsibility for the selection, use and maintenance of any product. Responsibility for proper selection, use and maintenance of any product remains with the purchaser and enduser. | | |
| | | |
| | | Emerson Process Management Fisher Controls International LLC Portsmouth, NH 03801 T: 1 (603) 766-8500 F: 1 (603) 766-8590 www.baumann.com | | |
| | | EMERSON Process Management | | |
| | | |
| | | © Fisher Controls International LLC 2008; All Rights Reserved. Printed in USA | | |
| | | |
| | | | | |
| | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |