Reliable evaluation Measurement data statistics are available at the push of a button, optionally as an individually configurable list – with characteristic statistical values such as mean value, standard deviation, confidence interval and others. In addition, various graphical display formats provide a clear overview. Sum frequency diagram and histogram provide easily seen indications of potential systematic influences in measurement series. It is understood that there is targeted comparisons of measurement blocks. Production processes can be evaluated at one glance, and differences between various shipments can be pinpointed quickly during the incoming inspection. In no time, coating thickness measurement with the DUALSCOPE® FMP100 becomes a routine. Exact measurements The DUALSCOPE® FMP100 and the F-probes form an integral measurement system, harmonized for best-possible trueness and optimum repeatability precision. The high precision of the probes ensures a significantly increased measurement range – exceeding the typical range. Both very thin and thick coatings can be measured precisely. A sturdy plug-type connector ensures a reliable connection between instrument and probe. The DUALSCOPE® FMP100 combines two physical measurement methods and conforms to many standards and practices. • Non-magnetic coatings on ferromagnetic substrate materials (using the magnetic induction method according to DIN EN ISO 2178, ASTM B499), e.g., zinc, chromium, copper, tin or paint, varnish, plastics, enamel on iron or steel. • Electrically non-conducting coatings on NF-metals (using the eddy current method according to DIN EN ISO 2360, ASTM B244), e.g., paint, varnish or plastics on aluminum, brass or zinc as well as anodized coatings on aluminum. • ASTM D7091-05 – standard practice for nondestructive measurement of dry film thickness of non-magnetic coatings applied to ferrous metals and non-magnetic, non-conductive coatings applied to non-ferrous metals. Technical data and features (brief overview) Instrument platform Application software based on MS Windows™ CE Display Bright graphics display (color, touchscreen) Keyboard/operation 4 membrane keys, softkeyboard, up to 12 softkeys Probe connector Rugged connector socket, 10-pin Communication interface USB4 (model: Mini-AB) for connecting a printer or a PC Memory 256 MByte for meas. applications and meas. data Statistics • Mean value, standard deviation, Cp, Cpk et al. • Final result, histogram, sum frequency Safety mechanisms • Applications and system password protected • Automatic saving of data Data export • Measurement printforms generated in PDF • Data output in ASCII format, e.g., to a PC Languages us, de, fr, it, es, cn, jp Power supply Battery/rechargeable battery operation (e.g., Mignon LR6) or via AC adapter 110/230 VAC3 Dimensions/weight • 170 x 89 x 40 (H x W x D, in mm) • approx. 395 g (without probe, ready to operate) Handling/ • Shoulder carrying strap transporting aid • Desk stand for the instrument (fold-out design) Operating temperature +10 °C … +40 °C 3 One battery set (4 x Mignon LR6) and the AC adapter are included with the shipment. 4 Compatible with USB2.0 Drag-and drop configuration of printform templates Order information Product Order no. DUALSCOPE® FMP1001 604-140 Measurement probes2 Measurement probe FD10 – DUAL probe for magnetic induction and eddy current measurement methods 604-143 Meas. probe FGAB 1.3 – for the magnetic induction meas. method 604-141 Meas. probe FTA 3.3H – for the eddy current meas. method 604-142 Optional accessories Rechargeable battery pack 604-144 Communication cable for printer port (USB4), 604-145 Printer F6000 – Inkjet, Color, USB4 603-409 PC-Datex Software for data transfer to Excel® spreadsheets 602-465 PC-Datacc Software for data transfer to Access® data bases 603-028 Measurement stand V12 602-260 Spare parts Plug-in AC adapter 110/230 VAC primary 603-233 Stylus – for operating the software 604-153 1 Included in the shipment (without probe) are: Measurement instrument with protective film for the display, operating instructions, carrying case, stylus, AC adapter, batteries (4 x LR6), communication cable between DUALSCOPE® FMP100 and PC (incl. driver library on CD-ROM). 2 Select probe model based on measurement application and order separately; not part of the standard shipment of the DUALSCOPE® FMP100 (instrument). ® © HELMUT FISCHER GMBH INSTITUT FÜR ELEKTRONIK UND MESSTECHNIK Subject to change 902-009 Printed in Germany 02/08 HELMUT FISCHER GMBH INSTITUT FÜR ELEKTRONIK UND MESSTECHNIK Industriestraße 21 71069 Sindelfingen, Germany Tel. +49 (0) 70 31 / 3 03 - 0 Fax +49 (0) 70 31 / 3 03 - 79 mail@helmut-fischer.de www.helmut-fischer.com Helmut Fischer AG CH-6331 Hünenberg, Switzerland Tel. +41 (0) 41 785 08 00, Fax +41 (0) 41 785 08 01 switzerland@helmutfischer.com www.helmutfischer.com Branch Offices of Helmut Fischer AG, Switzerland: Fischer Instrumentation Electronique 78180 Montigny le Bretonneux, France Tel. +33 1 30 58 00 58, Fax +33 1 30 58 89 50 E-Mail: france@helmutfischer.com Helmut Fischer S.R.L., Tecnica di Misura 20128 Milano, Italy Tel. +39 0 22 55 26 26, Fax +39 0 22 57 00 39 E-Mail: italy@helmutfischer.com Fischer Instrumentation (G.B.) Ltd. Gordleton Industrial Park Hannah Way, Pennington Lymington/Hampshire SO41 8JD, England Tel. +44 (0) 15 90 68 41 00, Fax +44 (0) 15 90 68 41 10 mail@fischergb.co.uk www.fischergb.co.uk Fischer Instruments, S.A. 08018 Barcelona, Spain Tel. +34 9 33 09 79 16, Fax +34 9 34 85 05 94 E-Mail: spain@helmutfischer.com Helmut Fischer Meettechniek B.V. 5627 GB Eindhoven, The Netherlands Tel. +31 4 02 48 22 55, Fax +31 4 02 42 88 85 E-Mail: netherlands@helmutfischer.com Fischer Instruments K.K. Saitama-ken 340-0012, Japan Tel. +81 4 89 29 34 55, Fax +81 4 89 29 34 51 E-Mail: japan@helmutfischer.com Fischer Instrumentation (Far East) Ltd. Kwai Chung, N.T., Hong Kong Tel. +852 24 20 11 00, Fax +852 24 87 02 18 E-Mail: hongkong@helmutfischer.com Fischer Technology, Inc. 750 Marshall Phelps Road Windsor, CT 06095, USA Tel. +1 86 06 83 - 07 81, Fax +1 86 06 88 - 84 96 info@fischer-technology.com www.fischer-technology.com Fischer Instrumentation (S) Pte Ltd. Singapore 118529, Singapore Tel. +65 62 76 67 76, Fax +65 62 76 76 67 E-Mail: singapore@helmutfischer.com Nantong Fischer Instrumentation Ltd. Shanghai 200437, P.R.C., China Tel. +86 21 65 55 74 55, Fax +86 21 65 55 24 41 E-Mail: china@helmutfischer.com Fischer Measurement Technologies (India) Pvt. Ltd. Pune 411036, India Tel. + 91 20 26 82 20 65, Fax + 91 20 26 82 20 75 E-Mail: india@helmutfischer.com DKD-K-33101 Accredited acc. to DIN EN ISO/IEC 17025 Certified according ISO9001:2000 Germanischer Lloyd Certification 03/08

pageCatalog pdf di En 2012-05-22-29