E340 BOILER ROOM CONTROL - FIREYE - #1

/ 44


catalogue search
E340 BOILER ROOM CONTROL - FIREYE
P. 01
E340 BOILER ROOM CONTROL - FIREYE
P. 02
E340 BOILER ROOM CONTROL - FIREYE
P. 03
E340 BOILER ROOM CONTROL - FIREYE
P. 04
E340 BOILER ROOM CONTROL - FIREYE
P. 05
E340 BOILER ROOM CONTROL - FIREYE
P. 06
E340 BOILER ROOM CONTROL - FIREYE
P. 07
E340 BOILER ROOM CONTROL - FIREYE
P. 08
E340 BOILER ROOM CONTROL - FIREYE
P. 09
E340 BOILER ROOM CONTROL - FIREYE
P. 10
E340 BOILER ROOM CONTROL - FIREYE
P. 11
E340 BOILER ROOM CONTROL - FIREYE
P. 12
E340 BOILER ROOM CONTROL - FIREYE
P. 13
E340 BOILER ROOM CONTROL - FIREYE
P. 14
E340 BOILER ROOM CONTROL - FIREYE
P. 15
E340 BOILER ROOM CONTROL - FIREYE
P. 16
E340 BOILER ROOM CONTROL - FIREYE
P. 17
E340 BOILER ROOM CONTROL - FIREYE
P. 18
E340 BOILER ROOM CONTROL - FIREYE
P. 19
E340 BOILER ROOM CONTROL - FIREYE
P. 20
E340 BOILER ROOM CONTROL - FIREYE
P. 21
E340 BOILER ROOM CONTROL - FIREYE
P. 22
E340 BOILER ROOM CONTROL - FIREYE
P. 23
E340 BOILER ROOM CONTROL - FIREYE
P. 24
E340 BOILER ROOM CONTROL - FIREYE
P. 25
E340 BOILER ROOM CONTROL - FIREYE
P. 26
E340 BOILER ROOM CONTROL - FIREYE
P. 27
E340 BOILER ROOM CONTROL - FIREYE
P. 28
E340 BOILER ROOM CONTROL - FIREYE
P. 29
E340 BOILER ROOM CONTROL - FIREYE
P. 30
E340 BOILER ROOM CONTROL - FIREYE
P. 31
E340 BOILER ROOM CONTROL - FIREYE
P. 32
E340 BOILER ROOM CONTROL - FIREYE
P. 33
E340 BOILER ROOM CONTROL - FIREYE
P. 34
E340 BOILER ROOM CONTROL - FIREYE
P. 35
E340 BOILER ROOM CONTROL - FIREYE
P. 36
E340 BOILER ROOM CONTROL - FIREYE
P. 37
E340 BOILER ROOM CONTROL - FIREYE
P. 38
E340 BOILER ROOM CONTROL - FIREYE
P. 39
E340 BOILER ROOM CONTROL - FIREYE
P. 40
E340 BOILER ROOM CONTROL - FIREYE
P. 41
E340 BOILER ROOM CONTROL - FIREYE
P. 42
E340 BOILER ROOM CONTROL - FIREYE
P. 43
E340 BOILER ROOM CONTROL - FIREYE
P. 44
Pages:
E340 BOILER ROOM CONTROL - FIREYE


See other catalogues for FIREYE

Text version of the page
E-3401 AUGUST 3, 2007
E340 BOILER ROOM CONTROL
Technical Description
and
Set-up Manual
APPROVED
DESCRIPTION
The E340 Boiler Room Control is a microprocessor-based Boiler Management System designed to interface with and expand on the capabilities of the existing FIREYE® FLAME-MONITOR™ and "D" Series Flame safeguard control systems, as well as competitive flame safeguard systems. Fol­lowing are some of the monitor and control capabilities provided by the E340:
• Operating Control Function for automatic sequencing of the boiler system to start and stop the boiler to meet system demand.
• Full Modulation Control of fuel and combustion air through the firing rate motor to meet sys­tem demand.
• Solid State Sensors to monitor steam pressure, water temperature, oil pressure, gas pressure, oil temperature, stack temperature, boiler water temperature, or outdoor air temperature.
• High and Low Pressure and Temperature Alarm Limits (user selectable) based on inputs from solid state sensors. Exceeded limits will open interlock circuit to the flame safeguard con­trol for shutdown of the burner and boiler.
• Cold Start Thermal Shock Protection to slowly increase the burner firing rate on a cold start to limit mechanical stress due to thermal differences.
• Interface with an Existing Flame Safeguard Control (Fireye FLAME-MONITOR, D-Series, or competitive flame safeguard control to provide ease of installation in a retrofit application.
• Lead/Lag operation of two boilers.
• Remote Communication Capability to access system information via IBM compatible PC and E340 Communications Software.
• Keypad/Display Module with 8 character LCD Display and 12 key keypad for on-site pro­gram and review of system setpoints and operating parameters.
• Software Password Protection (two levels of security) to restrict unauthorized entry and mod­ification of system setpoints and operating parameters.
• Time of Day scheduling to program set-back of water temperature or steam pressure setpoints.
• Timed Override of Setback Schedule via momentary push button. Override period keypad
selectable.
• Marginal High and Low Pressure and Temperature Alarm Limits (user selectable) based on input from solid state sensors to indicate system approaching high or low alarm limits.
• Auxiliary Analog Output (4-20 mA) to provide an output signal (to a chart recorder) that is directly proportional to one of the five pressure or temperature sensors.
• Programmable Maximum High Fire Position of modulating firing rate damper motor.