Catalog excerpts

The FE is a butterfly valve for shutting off or regulating flow, specifically designed for water applications and equipped with a customisable Labelling System. BUTTERFLY VALVE • Disk in PVC-U with through shaft • Zinc plated square section steel stem completely isolated from the fluid complying with standard ISO 5211: DN 40 - 65: 11 mm DN 80 - 100: 14 mm DN 125 - 150: 17 mm DN 200: 22 mm • Can also be installed as an end line valve, bottom discharge valve or tank dump valve • The wafer valve can be transformed into a one-way Lug body valve thanks to the set of zinc plated steel inserts available...

 Open the catalog to page 2

1 Ergonomic multifunctional handle in HIPVC with the option for quick operation, graduated adjustment in 12 positions (every 7.5°). 180° reversible mounting 2 Customisable Labelling System: integrated module, made of a transparent protection plug customisable tag holder using the LSE set (available as accessory). The customisation lets you identify the valve on the system according to the specific needs 3 Drilling pattern with oval slots that allow coupling to flanges according to numerous international standards 4 Interchangeable liner with the dual function of forming a hydraulic seal and isolating...

 Open the catalog to page 3

For water and non-hazardous fluids with regard to which the material is classified as CHEMICALLY RESISTANT. In other cases, a reduction of the nominal pressure PN is required (25 years with safety factor). Working temperature PRESSURE DROP GRAPH bar KV100 FLOW COEFFICIENT The Kv100 flow coefficient is the Q flow rate of litres per minute of water at a temperature of 20°C that will generate Ap= 1 bar pressure drop at a certain valve position. The Kv100 values shown in the table are calculated with the valve completely open.

 Open the catalog to page 4

RELATIVE FLOW COEFFICIENT GRAPH OPERATING TORQUE AT MAXIMUM WORKING PRESSURE Operating torque The information in this leaflet is provided in good faith. No liability will be accepted concerning technical data that is not directly covered by recognised international standards. FIP reserves the right to carry out any modification. Products must be installed and maintained by qualified personnel.

 Open the catalog to page 5

FEOV/LMHand operated Butterfly valve d DN FEOV/RMGearbox operated Butterfly valve 145 159 173 192 192 207 257 257 * FEOV D140 with special adaptor stubs D125 * FEOV D140 with special adaptor stubs D125

 Open the catalog to page 6

FE LUG INSERT Size range: DN 40 t- 200 mm. Standard: ISO-DIN. PN: 6-4 bar with water at 20° C (used as end line). Threaded inserts are available to transform all the PVC-U butterfly valves of the FEOV series into Lug body valves. The zinc plated steel inserts can be easily fitted before installing the valve in the system and allow the valve itself to be used as a single flange end line valve in total safety. Lug butterfly valves are the unidirectional type when used as end line valves with a single flange, or as a connecting element for maintenance operations without needing to drain the lines (1)...

 Open the catalog to page 7

ACTUATOR MOUNTING FLANGE The valve can be equipped with standard pneumatic or electric actuators and gearbox for heavy-duty operations, using a flange in PP-GR reproducing the drilling pattern provided for by standard ISO 5211. The FE valve is equipped with the customisable Labelling System. This system lets you create special labels to insert in the handle. This makes it extremely easy to apply company logos, identification serial numbers or service information such as, for example, the valve function in the system, the transported fluid, but also specific information for customer service, such...

 Open the catalog to page 8

1 • Handle (HIPVC - 1) 2 • Screw (STAINLESS steel - 1) 3 • Washer (STAINLESS steel - 1) 4 • Transparent protection plug (PVC - 1) 5 • Stem (Zinc plated steel - 1) 6 • Stem O-Ring (EPDM or FPM - 1) 7 • Stem O-Ring (EPDM or FPM - 1) 8 • Seeger ring (STAINLESS steel - 1) 9 • Bush O-Ring (EPDM or FPM - 2) 10 • Bush (Nylon - 1) 11 • Body (PVC-U - 1) 12 • Disk O-Ring (EPDM or FPM - 2) 13 • Anti-friction ring (PTFE - 2) 14 • Disk (PVC-U - 1) 15 • Liner (EPDM or FPM - 1) 16 • Washer (Steel- 1) 17 • Screw (STAINLESS steel - 1) 18 • Protection plug (PE - 1) 19 • Screw (STAINLESS steel - 2) 20 • Plate (PVC-U...

 Open the catalog to page 9

1 • Handle (HIPVC - 1) 2 • Screw (STAINLESS steel - 1) 3 • Washer (STAINLESS steel - 1) 4 • Transparent protection plug (PVC - 1) 5 • Stem (Zinc plated steel - 1) 6 • Stem O-Ring (EPDM or FPM - 1) 7 • Stem O-Ring (EPDM or FPM - 1) 8 • Seeger ring (STAINLESS steel - 1) 9 • Bush O-Ring (EPDM or FPM - 2) 10 • Bush (Nylon - 1) 11 • Body (PVC-U - 1) 12 • Disk O-Ring (EPDM or FPM - 2) 13 • Anti-friction ring (PTFE - 2) 14 • Disk (PVC-U - 1) 15 • Liner (EPDM or FPM - 1) 16 • Washer (Steel- 1) 17 • Screw (STAINLESS steel - 1) 18 • Protection plug (PE - 1) 19 • Screw (STAINLESS steel - 2) 20 • Plate (PVC-U...

 Open the catalog to page 10

1) Remove the LCE module consisting of the rigid transparent PVC plug (4a-4b) and white tag holder (23) and remove screw (2) and washer (3). 3) Remove the protection plug (18) and screw (17) with the washer (16). 4) Extract the stem (5) and disk (14). 5) Remove the liner (15) from the body (11). 6) Remove the Seeger ring (8) and guide bush (10). 1) Place the liner (15) on the body (11). 3) Insert the gaskets (9) on the guide bush (10) and the bush on the stem. Lock the bush using the Seeger ring (8). 4) Position the O-rings (12) and then the anti-friction rings (13) on the disk (14) and the disk...

 Open the catalog to page 11

To install on PVC-U stubs, check the valve-stub-flange couplings in the following table. Short/long spigot stubs according to EN ISO 15494 and DIN 16962/16963 and flange

 Open the catalog to page 12

Before tightening the stud-bolts, it is advisable to open the disk in order to prevent damage to the seal. Tighten the stud-bolts in a uniform manner, in the order indicated in the figure, to the operating torque value indicated in the table. The stud-bolts do not need to be excessively tightened in order to produce a perfect hydraulic seal. Overtightening could adversely affect the operating torque of the valve * Tightening torques for nuts and bolts on couplings with backing ring. Values required to obtain the hydraulic test (1.5xPN at 20°C) (new or lubricated nuts and bolts) Make sure that...

 Open the catalog to page 13

All FIP - Formatura Iniezione Polimeri catalogs and technical brochures

  1. VKD DN 10÷50

    16 Pages

    En
  2. VKD Dual Block

    6 Pages

    En
  3. TKD Dual Block

    14 Pages

    En
  4. SXE-SSE EASYFIT

    24 Pages

    En
  5. DK DIALOCK 2017

    12 Pages

    En
  6. S1-S2

    12 Pages

    En
  7. DK DN

    16 Pages

    En
  8. DK CP

    45 Pages

    En
  9. VM/RM DN 8÷15

    6 Pages

    En
  10. SXE-SSE DN 10÷50

    17 Pages

    En
  11. DK DN 15÷65

    16 Pages

    En
  12. DK/CP DN 15÷20

    20 Pages

    En
  13. PROMO FS-FC

    16 Pages

    En
  14. PVC-U Fittings

    98 Pages

    En
  15. PVC-U Manual Valves

    246 Pages

    En
  16. PP-H (100) System

    198 Pages

    En
  17. PVDF System

    141 Pages

    En