Pressure Level Transmitter
12Pages

{{requestButtons}}

Catalog excerpts

Pressure Level Transmitter - 1

Your Made-To-Order Solutions

Open the catalog to page 1
Pressure Level Transmitter - 2

PRODUCT INTRODUCTION 1. FineTek Models include: extension cable transducer, Anti-corrosive model, flanged models & pressure transducers. 2. Can be connected to digital panel meters, recorders, PLC, signal controllers. 3. The metal diaphragm is suitable in as weak acid and alkaline liquids or sewage water treatment. 4. Our internal temperature compensation ensures long lasting reliability. 5. Customized flange/screw sizes available. Panel Meter THEORY A pressure sensor is made up of a piezoresistor Wheatstone bridge. Fig. (1) As shown in fig.2, the pressure is applied to the diaphragm and...

Open the catalog to page 2
Pressure Level Transmitter - 3

EC1100 EC1110 Extension Tube Flange Model Extension Tube Screw Model Housing material Pressure range Measuring range 0~1M,0~2M,0~4M 0~1M,0~2M,0~4M (assumed with the water S.G:1) (assumed with the water S.G:1) 0~1M,0~2M,0~5M,0~10M, 0~20M,0~50M,0~100M (assumed with the water S.G:1) Operating temp Ambient temp Supply voltage 4~20mA,Loop resistance should be less than 500 W 4~20mA,Loop resistance should be less than 500 W 4~20mA,Loop resistance should be less than 500 W Long term stability Output Connection Wetted material Weight ※Special size flange and screws are available. ※OEM/ODM is welcome.

Open the catalog to page 3
Pressure Level Transmitter - 4

EC1210 Flange Standard Model EC1310 EC1300 Extension Cable Flange Model Extension Cable Screw Model Housing material Pressure range Measuring range Linearity 0~1M,0~2M,0~4M (assumed with the water S.G:1) 0~1M,0~2M,0~4M,0~10M, 0~1M,0~2M,0~5M,0~10M, 0~20M,0~50M,0~100M 0~20M,0~50M,0~100M (assumed with the water S.G:1) (assumed with the water S.G:1) Ambient temp Supply voltage 4~20mA,Loop resistance should be less than 500 W 4~20mA,Loop resistance should be less than 500 W 4~20mA,Loop resistance should be less than 500 W Wetted material Long term stability Operating temp Output Connection...

Open the catalog to page 4
Pressure Level Transmitter - 5

EC1320 Extension Cable Model EC2500 Extension Cable Model Pressure range Measuring range Linearity 0~1M,0~2M,0~5M,0~10M, 0~2.5M,0~4M,0~6M 0~20M,0~50M,0~100M (assumed with the water S.G:1) (assumed with the water S.G:1) 0.3%FS Ambient temp Supply voltage 4~20mA,Loop resistance should be less than 500 W 4~20mA,Loop resistance should be less than 500 W 4~20mA,Loop resistance should be less than 500 W Long term stability Operating temp Output Protection Wetted material Weight ※Special size flange and screws are available. ※OEM/ODM is welcome.

Open the catalog to page 5
Pressure Level Transmitter - 6

INTERNAL WIRING 1. Ensure power is turned off before connecting. See fig.3, 4 or 5 (depending on the model). 2. Make sure the outlet breather capillary is open for air to flow freely. EC1500 TYPE 1. Remove the cover of plug and connect cable to the 3. Please tighten the cover and cable gland after the wiring is finished. Ground 4. The cable should be at least 18 AWG or 16 AWG. Plug Ground Green Breather capillary Break White Shield wire 2. When wiring is finished, assemble the plug with cover. SPAN Socket Breather capillary

Open the catalog to page 6
Pressure Level Transmitter - 7

EXTERNAL WIRING 1. When connecting panel meters, please refer to the wiring diagram attached and the related operation manual. 2. Wiring connection should be kept away from high voltage cables, (e.g. power cables) to prevent electrical interference. Shield wire 3. Operating voltage should be kept higher than 13Vdc. 4. Wiring should be used in shielded insulated cable. Breather capillary 5. Provide additional power supply if required (Diagram 8). If installing 2 panel meters at different location, please refer to diagram 9. Panel meter Extra DC Power Supply Pressure Sensor Digital panel...

Open the catalog to page 7
Pressure Level Transmitter - 8

INSTALLATION 1. Note the installation diagrams to the right and select your model accordingly. EC1100 EC1300 2. The flange type transducer is equipped with a side mounted electrical housing. 3. The models EC1100 to EC1310 series have 3 multi-thread copper wires and a breather capillary. Avoid bending cables to ensure maximum accuracy. 4. 4. Do not use liquid that can crystallize or solidify in the pressure transducers and sensors. 5. The tank or vessel should not be vacuum or no pressure state. 8. Handle the sensor probes with care. The sensor probe is delicate and vibration or shock can...

Open the catalog to page 8
Pressure Level Transmitter - 9

1 Since Zero & Span adjustment have been made in the factory. Don't change the setting unless necessary. Zero represents the 4mA for an empty tank and Span represents the 20mA for a full tank. 1 Adjustment range: (SPAN) 18~24mA, (ZERO) 3~5mA. 1 In the case where sensor output requires more than the 4~20mA signal, a panel meter with programmable input (0~25.5mA) can be used. ZERO The electrical housing for transducer with flange. ZERO The electrical housing for pressure transducer. Pressure Unit Conversion Constants PSI

Open the catalog to page 9
Pressure Level Transmitter - 10

EC 1 1 0 0 E M ( 0 1 0 0 ) MODEL 110: Extension Tube Flange Type 111: Extension Tube Screw Type 130: Extension Cable Flange Type 131: Extension Cable Screw Type 132: Extension Cable Type E: PTFE (EC130 Extension Cable Type ) MODEL 120: Hi-Temp. Flange Type 121: Flange Standard Type Total product length tolerance: A5mm Characteristics, specifications and dimensions are subject to change. Please contact your nearest distributing office for further informations. 9

Open the catalog to page 10
Pressure Level Transmitter - 11

Total product length tolerance: A5mm Characteristics, specifications and dimensions are subject to change. Please contact your nearest distributing office for further informations.

Open the catalog to page 11
Pressure Level Transmitter - 12

Mini Float/Magnetic Float Level Switch Magnetic Float Level Transmitter Side Mounting Float Switch Cable Float Level Switch Thermal Dispersion Flow Switch Paddle Flow Switch Optical Level Switch Rotary Paddle Level Switch Capacitance Level Switch Pressure Level Transmitter Vibrating Probe Level Switch Tuning Fork Level Switch RF-Capacitance Level Transmitter RF-Capacitance / Admittance Level Switch Magnetostrictive Level Transmitter By-Pass Level Transmitter FMCW Radar Level Transmitter Electromechanical Level Measuring System Ultrasonic Level Transmitter Mini By-Pass Level Transmitter...

Open the catalog to page 12