INTRODUCTION FEATURES Adapts microprocessor control circuit, modular design, advanced digital calibration, and switching power supply technology. Modulized design is a concept to adapt different analog input signals by means of changing different signal board (such as temperature, pressure, alternating voltage, electric current.). Also, optional output board could add the analog output signal (isolated). By using advanced digital calibration capability, its analog input/output could be accurate to +/- 1 bit. PB SERIES---BARGRAPH DISPLAY PM SERIES---DIGITAL DISPLAY It is easy to tell the...

Open the catalog to page 2
Microprocessor Based Bargraphic Display Scaling Meter - 3

NON-LINEAR TANK VOLUME CONVERSION FEATURE NON-LINEAR TANK VOLUME CONVERSION FEATURE PM/PB Series support volume adjustment function for non-linear tanks. By means of a 20-point look-up table, panel meter calculate tank volume according to the material level measured. Bundled with this package, a software is provided, user simply select tank type shown as below, and enter necessary dimension, tank volume and 20 control points will be calculated and reported. TANK TYPE: Length Width Length Height 1 Height Diameter Height 2 Width Length Width Diameter Diameter Height 1 Height 1 Height Height 2...

Open the catalog to page 3
Microprocessor Based Bargraphic Display Scaling Meter - 4

SPECIFICATIONS Microprocessor Bargraph Display Panel Meter Appearance Dimension (mm) 48 (W) x144 (H) x121.5 (D) 48 (W) x144 (H) x121.5 (D) DIN 3/16 DIN 3/16 Model 144 (W) x48 (H) x121.5 (D) DIN 3/16 144 (W) x48 (H) x121.5 (D) DIN 3/16 PB-1470 PB-1570 Standard Display Range Input signal PB-1471 Dual Row 4-digit 7-segment LED Display PB-2471 4 Digits 7-Segment LED 4 Digits 7-Segment LED 5 Digits 7-Segment LED Dual Column 101-segment LED Bargraph Display Totally 8 Set Points 101 LED Bargraph Display Totally 6 Set Points 101 LED Bargraph Display Totally 6 Set Points 101 LED Bargraph Display...

Open the catalog to page 4
Microprocessor Based Bargraphic Display Scaling Meter - 5

SPECIFICATIONS Microprocessor Digit Display Panel Meter Appearance Dimension (mm) 96 (W) x48 (H) x128.5 (D) DIN 1/8 96 (W) x48 (H) x128.5 (D) DIN 1/8 96 (W) x48 (H) x128.5(D) DIN 1/8 96 (W) x48 (H) x128.5(D) DIN 1/8 Model PM-1430 PM-2430 PM-1530 PM-1430-W (4 digit) PM-1530-W (5 digit) Display 4 Digits 7-Segment LED 5 Digits 7-Segment LED 5 Digits 7-Segment LED Totally 4 Set Points Totally 4 Set Points -1999 ~ +9999。 -19999 ~ +32767。 -1999 ~ +9999。 -19999 ~ +99999。 20mA, 200mA, 5V, 10V, 20V ,200V 20mA, 200mA, 5V, 10V, 20V ,200V 20mA, 200mA, 5V, 10V, 20V ,200V 20mA, 200mA, 5V, 10V, 20V ,200V...

Open the catalog to page 5
Microprocessor Based Bargraphic Display Scaling Meter - 6

Microprocessor Bargraph Display Panel Meter TERMINAL ARRANGEMENTS: (Option) Isolated 1 2 3 4 5 6 7 8 Signal GND Volt Input Current Input Signal GND { 9 10 11 12 13 14 15 16 17 18 CH2 SP2 CH2 SP1 CH1 SP2 CH1 SP1 AUX. POWER FEATURES: Dual 4 Digits LED Numeric Display +24V GND Analog O/P+ Analog GND Analog O/P+ Analog GND 19 20 21 CH1 22 23 24 CH2 25 26 27 28 29 30 31 32 33 34 35 36 { CH1 { CH2 + { EXC 24V GND Volt Input Current Input { PB-2471 RS485 - CH2 SP4 CH2 SP3 CH1 SP4 CH1 SP3 EXTERIOR/CUTOUT DIMENSIONS ( Unit:mm) 6 (max.) Dual 101-segment LED Bargraph display 45 +0.6 -0 48 Wide Range...

Open the catalog to page 6
Microprocessor Based Bargraphic Display Scaling Meter - 7

Microprocessor Bargraph Display Panel Meter Volt Input Signal- Current Input Signal- Signal GND—i ■ 4 Digits LED Numeric Display ■ Wide Range of User Definable Scaling Ratio -i Modulized input signal boards available for different applications -i Optional Output Boards with Isolated Analog Output & Relay Output -i85V~265VAC or 18-36VDC Switching Power Supply ■ Support volume adjustment function for non-linear tanks EXTERIOR/CUTOUT DIMENSIONS ORDERING INFORMATION: cation port 0—0 Relays 2—2 Relays 4—4 Relays 6—6 Relays 1 —Support 20 points Vessel Conversion Represents: PB-1471 Model, Power...

Open the catalog to page 7
Microprocessor Based Bargraphic Display Scaling Meter - 8

Microprocessor Bargraph Display Panel Meter LQ^C-I LJ^O-I LQ^J LQ^O-I ■ 4 Digits LED Numeric Display ■ Wide Range of User Definable Scaling Ratio -i Modulized input signal boards available for different applications -i Optional Output Boards with Isolated Analog Output & Relay Output -i85V~265VAC or 18-36VDC Switching Power Supply ■ Support volume adjustment function for non-linear tanks EXTERIOR/CUTOUT DIMENSIONS Power supply Power supply for sensor Input signal Relay contact Analog output Power comsumption Communication port Operating condition Storage condition Switching Power Supply...

Open the catalog to page 8
Microprocessor Based Bargraphic Display Scaling Meter - 9

Microprocessor Bargraph Display Panel Meter ■ 5 Digits LED Numeric Display ■ Wide Range of User Definable Scaling Ratio -i Modulized input signal boards available for different applications -i Optional Output Boards with Isolated Analog Output & Relay Output -i85V~265VAC or 18-36VDC Switching Power Supply ■ Support volume adjustment function for non-linear tanks EXTERIOR/CUTOUT DIMENSIONS Switching Power Supply Power supply for sensor DC24V, 50mA Power supply Input signal Relay contact Over Range Display: "1" or "-1" Range: Refer to Ordering information Sampling Rate: ORDERING INFORMATION:...

Open the catalog to page 9
Microprocessor Based Bargraphic Display Scaling Meter - 10

Microprocessor Digit Display Panel Meter ■ 4 Digits LED Numeric Display ■ Wide Range of User Definable Scaling Ratio ■ Modulized input signal boards available for different applications ■ Optional Output Boards with Isolated Analog Output & Relay Output ■ 85V-265VAC or 18-36VDC Switching Power Supply ■ Support volume adjustment function for non-linear tanks J IP54 Class front panel EXTERIOR/CUTOUT DIMENSIONS ORDERING INFORMATION: cation port 0—0 Relays 2—2 Relays 4—4 Relays 1 —Support 20 points Vessel Conversion Represents: PM-1430 Model, Power supply 85-265V AC, Analog input signal 4~20mA,...

Open the catalog to page 10
Microprocessor Based Bargraphic Display Scaling Meter - 11

Microprocessor Digit Display Panel Meter ■ Dual Channel Signal Input ■ Dual 4 Digits LED Numeric Display ■ Wide Range of User Definable Scaling Ratio ■ Modulized input signal boards available for different applications ■ Optional Output Boards with Isolated Analog Output & Relay Output ■ 85V-265VAC or 18-36VDC Switching Power Supply ■ Support volume adjustment function for non-linear tanks -i IP54 Class front panel EXTERIOR/CUTOUT DIMENSIONS ORDERING INFORMATION: cation port 0—0 Relays 2—2 Relays 4—4 Relays 6—6 Relays 1 —Support 20 points Vessel Conversion Represents: PM-2430 Model, Power...

Open the catalog to page 11

All FineTek Co. catalogs and technical brochures

  1. Thermocouple

    12 Pages