Group: FINETEK
Catalog excerpts
Magnetostrictive Level Transmitter Your Made-To-Order Solutions
Open the catalog to page 1The FineTek magnetostrictive level transmitter identifies the level of liquids and solutions with high precision and reliability. Absolute positioning output and no calibration requiredafter power failure. Stability and reliablity. Ease installation without calibration & maintenance. Prompt response time, high resolution & high accuracy. Durable structure, dust-proof, withstands high pressure. Oil/water dual level indication. The Max. operation temp. is 200BC. EG31, 32, 36, 37 adopted loop power structure for wire saving. Explosion-proof model available for hazardous environments. Housing...
Open the catalog to page 2OPERATING PRINCIPLE CONVERSION FORMULA The sensor mainly consists of magnetorestrictive wires sealed in a stem/rod and a permanent magnet sealed into a float that can move up and down the stem.Electrical current travels along the wires in the stem creating an axial magnetic field. When the float’s and stem’s magnetic field intersect, a torsional force is created with different height levels (see right). The sensor measures the liquid level (D) by calculating the elapsed time between torsional forces. Using velocity and time, distance can be calculated.This action is timely and continuous. A...
Open the catalog to page 3STANDARD MODEL (2 Wire) EG31 (High Temperature Model) Two-wire loop power output, for Oil/Water interface, pharmaceutical and food grade level control. Two-wire loop power output, high process environment application. Measuring range Non-Linearity A0.05% F.S. or K1.0mm (whichever is greater) A0.05% F.S. or K1.0mm (whichever is greater) Temp. coefficient Operation pressure Operation temp. Temp. accuracy Maximum load Digital output Power supply Ambient temp. Housing material Connection Wetted material Enclosure
Open the catalog to page 4HIGH ACCURACY MODEL (2 Wire/4 Wire) EG32 (High Accuracy Model) EG34 (High Accuracy Model) Two-wire loop power output, comply with high accuracy & HART demands. Four wire output,high speed active in low voltaye 5V. Temp. coefficient Operation pressure Operation temp. Temp. accuracy Maximum load Digital output Power supply Measuring range Ambient temp. Housing material Connection Wetted material Enclosure
Open the catalog to page 5EXPLOSION PROOF MODEL (2 Wire) NEPSI PROOF No.GYB101836X Ex ia IIB T2~T6 PTB PROOF NO.13 ATEX 2016X II 1G Ex ia IIB T3~T6 M12 Model No. Application Measuring range Non-Linearity EG371 (Single/dual Float Model) Two-wire loop power output, for acid/alkali corrosion liquids. Two-wire loop power output, for single/dual level and interface measurement. A0.05% F.S. or K1.0mm (whichever is greater) A0.05% F.S. or K1.0mm (whichever is greater) Temp. coefficient Operation pressure Ambient temp. Operation temp. Temp. accuracy Digital output Power supply Housing material Connection Wetted material...
Open the catalog to page 6EXPLOSION PROOF MODEL (2 Wire) NEPSI PROOF No.GYB101836X Ex ia IIB T2~T6 PTB PROOF13 ATEX 2016X II 1G Ex ia IIB T3~T6 NEPSI PROOF No.GYB14.1530X Ex ia IIB T3~T6Ga 167 M12 EG37A (Ex-proof High Temp. Model) Two-wire loop power output, explosion-proof model for hazadous environment. Two-wire loop power output, explosion-proof model with diaplay for hazadous environment. Temp. coefficient Operation pressure Ambient temp. Operation temp. Temp. accuracy Digital output Power supply Application Measuring range Housing material Connection Wetted material Enclosure Comply with safety barrier of Ex ia...
Open the catalog to page 7HOUSING OPTIONS Mapping table of enclosure Side conduit ^ Standard model cable length is 2m.
Open the catalog to page 8FLOAT SPECIFICATIONS
Open the catalog to page 9When RS485(ModBus)is applied,Loop power only as power. EG31/EG32/EG37: 1. Single / Double float +RS485 Loop Power 24VdcK10% Brown Loop Power 2. Single / Double float +HART ※The voltage or current is only alternative.
Open the catalog to page 10CUSTOMIZED STEM LENGTHS ARE AVAILABLE Note the difference between ordered length and actual measurable stem length below. (2M below )= Actual measurable length (X) =Ordered length (L)-52mm-15mm,adopted stem f12.7 (2M above )= Actual measurable length (X) =Ordered length (L)-73mm-15mm,adopted stem f16 (2M below )= Ordered length (L)=Actual measurable length (X)+52mm-15mm,adopted stem f12.7 (2M above )= Ordered length (L)=Actual measurable length (X)+73mm-15mm,adopted stem f16 Below 2M,stem f12.7 Blanking zone (end) 15mm Actual measurable length (X) Above 2M,stem f16 Blanking zone (end) 15mm...
Open the catalog to page 11Loop power 24Vdc ±10% The product is calibrated before shipment and should be sufficient to meet user needs. Do not bend the stem, put pressure on it or force it in any manner. For best results, use the included float only. 5. When the mounting hole is large enough, guide the stem and float through the hole to install. 6. If the hole is NOT large enough, remove float, install the stem and assemble float from inside the container. 7. When assembling the float onto the stem, the float's direction mark should face the housing. 8. Ensure the float stopper is fixed firmly. 9. If the stem is bent...
Open the catalog to page 12HOW TO ORDER E G 31 Housing Standard (-40~125BC) High Temp. (-40~200BC) A: Top conduit 1: Top conduit 2: Side conduit 4: Top conduit with coated 5: Side conduit with coated Q---PT R---PF T---BSP U---NPT V---GAS S---Others If installing directly(without removing float), the dimension of connection must be bigger than the float diameter. Please see chart below Please see chart below Special Specification ※ Probe diameter must be smaller than float's hole diameter. Analog output(Bottom~Top) A: 4~20mA B: 20~4mA 0: None ※ 4~20mA output direction can be selected. Digital output 0: None H: HART...
Open the catalog to page 13EG 3 2 Housing Standard 1: Top conduit 2: Side conduit High Temp. A: Top conduit B: Side conduit Anti-corrosion 4: Top conduit with coated 5: Side conduit with coated Q---PT R---PF T---BSP U---NPT V---GAS S---Others If installing directly(without removing float) ,the dimension of connection must be bigger than the float diameter. Please see chart below Please see chart below Special Specification ※ Probe diameter must be smaller than float's hole diameter. Digital output 0: None H: HART 7.3 ※ If the measuring range is over 2000mm, a stem f16 is recommended to reduce risk of damage during...
Open the catalog to page 14All FineTek Co. catalogs and technical brochures
-
EFX By-Pass Level Transmitter
34 Pages
-
EPD Electromagnetic Flow Meter
28 Pages
-
Tuning Fork Level Switch
32 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Temperature Transmitter
5 Pages
-
Thermocouple
12 Pages
-
Vibrating point level switch
14 Pages
-
SA Capacitance Level Switch
18 Pages
-
SE Rotary Paddle Level Switch
15 Pages
-
EC Pressure Level Transmitter
12 Pages
-
SQ Pressure Switch
12 Pages
-
SD Optical Level Switch
2 Pages
-
FF Side Mounting Float Switch
15 Pages
-
FC/FD Mini Float Level Switch
28 Pages
-
RF-Admittance Level Switch
11 Pages
-
Optical Level Switch
13 Pages
-
Rotary Paddle Level Switch
15 Pages
-
Magnetic Float Level Transmitter
14 Pages
-
RF-Admittance Level Transmitter
15 Pages
-
Capacitance Level Switch
18 Pages
-
Vibrating Probe Level Switch
10 Pages
-
Pressure Level Transmitter
12 Pages
-
Magnetic Float Level Switch
24 Pages
-
EF By-Pass Level Transmitter
23 Pages
-
Air Hammer/Pneumatic Vibrator
16 Pages
-
Mini Float Level Switch
28 Pages
-
Pressure Switch
12 Pages
-
PID+Fuzzy Temperature Controller
23 Pages
-
Cable Float Level Switch
12 Pages
-
Side Mounting Float Switch
15 Pages