Group: FINETEK
Catalog excerpts
RF-Capacitance Level Transmitter
Open the catalog to page 1PRODUCT INTRODUCTION RF-Capacitance level Transmitter utilizes the capacitance formed between the sensing probe and the reference probe or the metal vessel wall to calculate the level of the liquid/medium inside the vessel according to the capacitance theory that the capacitance and vessel are proportional increased. When sensing probe and detected media are fixed, media dielectric constant (Kmedia) is normally bigger than air (Kair=1). Capacitnce for media (Cmedia) increases when liquid/ power/ solid level raise. EB prouduct detects media level by calculating capacitance inside the tank. •...
Open the catalog to page 2STANDARD TYPE Suitable for big tank Media : non-conductive material low moisture material Suitable for big tank Media : non-conductive material low moisture material Suitable for middle/ small tank Media : non-conductive material low moisture material EB2101 Hi-Temp Wire Probe Probe Material Weight Material Ambient Temperature Operating Temperature Measuring Range Tensile Strength Operation Voltage Output Current Housing IP Degree Connection Weight Operating Pressure 3"x5kg/cm2 flange or 1"PT screw 3"x5kg/cm2 flange or 1"PT screw 1"x5kg/cm2 flange or 1"PT screw Approx. 3.7kg(1M)
Open the catalog to page 3STANDARD TYPE Suitable for non-conductive/ low moisture material and big tank.(weight can not be fixed at the bottom of tank) Suitable for non-conductive/ low moisture material and big tank.(weight can not be fixed at the bottom of tank) EB2301 Hi-Temp Wire Probe Suitable for middle/ small tank Media : non-conductive material low moisture material Probe Material Weight Material Ambient Temperature Operating Temperature Measuring Range Tensile Strength Operation Voltage Output Current Housing IP Degree Connection Weight Operating Pressure 1"x5kg/cm2 flange or 1"PT screw 1"x5kg/cm2 flange or...
Open the catalog to page 4STANDARD TYPE EB2400 --- PVDF Coating EB2420 --- PP Coating EB2430 --- FEP Coating Suitable for conductive/ Suitable for conductive/ corrosive material and middle-size corrosive material and middle-size tank. tank. Model No. Probe Material Hi-temp Anti-Corrosion Weight Material EB2520 --- PP Coating EB2530 --- FEP Coating Suitable for conductive/ corrosive material and middle-size tank.(weight can not be fixed at the bottom of tank) EB2520/30 Anti-Corrosion Wire Probe SUS304+Coating SUS304+PTFE Ambient Temperature Operating Temperature Tensile Strength Operation Voltage Measuring Range...
Open the catalog to page 5STANDARD TYPE Dimensions (unit:mm) Suitable for conductive/ corrosive material and middle-size tank.(weight can not be fixed at the bottom of tank) EB2531 Anti-Corrosion Hi-Temp Wire Probe Probe Material Weight Material Ambient Temperature Operating Temperature Tensile Strength Operation Voltage Output Current Measuring Range Weight Operating Pressure
Open the catalog to page 6STANDARD TYPE (MULTI-FUNCTION) Suitable for non-conductive material and middle-size tank. Model No. Probe material Suitable for non-conductive material and big tank. EB3400 --- PVDF Coating EB3420 --- PP Coating EB3430 --- FEP Coating Suitable for conductive/ corrosive material and middle-size tank. Weight material Ambient Temperature Operating Temperature Tensile strength Operation voltage Output current Output Linear Range Upper Limit Lower Limit Output Latch Measuring Range Housing IP Degree Connection Weight Operating pressure 1"x5kg/cm flange or 1"PT screw1"x5kg/cm flange or 1"PT screw
Open the catalog to page 7STANDARD TYPE (MULTI-FUNCTION) / COMPACT RAMP Dimensions (unit:mm) Dimensions (unit:mm) 尺寸圖 (單位:mm) Suitable for conductive/ corrosive material and small tank. EB3520 --- PP Coating EB3530 --- FEP Coating Suitable for conductive/ corrosive material and middle-size tank. EB3520/30 Anti-Corrosion Wire Probe Power supply Measuring range Probe material Output current Weight material Output Linear Range Ambient Temperature Operating Temperature Tensile strength Operation voltage Output current Lower Limit Output Latch Output Linear Range Upper Limit Upper Limit Lower Limit Output Latch Accuracy...
Open the catalog to page 8CALIBRATION & SETUP Display Value
Open the catalog to page 9ORDER INFORMATION 32 --- Rod Type 33 --- Wire Probe Type 34 --- Anti-Corrosion (3400: PVDF 3420: PP 3430: FEP) 35 --- Anti-Corrosion with Wire-probe weight (3520: PP 3530: FEP) 21 --- Wire Probe Type 21 --- Hi-Temp Wire Probe Type 22 --- Rod Type 22 --- Hi-Temp Rod Probe Type 23 --- Wire Probe Type 23 --- Hi-Temp Wire ProbeType 24 --- Anti-Corrosion (2400: PVDF 2420: PP 2430: FEP) 25 --- Anti-Corrosion with Wire-probe weight (2520: PP 2530: FEP) 26 --- Compact Ramp Material Metal Probe: Plastic Coated Probe: Temperature Resistance 0: Standard (max.100LC) 1: Hi-Temp Type (max.200LC)...
Open the catalog to page 10EXPLOSION PROOF TYPE Suitable for non-conductive material and big tank. Suitable for non-conductive material and big tank. Suitable for non-conductive material and middle-size tank. EB1711 Hi-Temp Wire Probe Probe material Weight material Ambient Temperature Operating Temperature Tensile strength Measuring Range Operation voltage Output current Operating pressure
Open the catalog to page 11EXPLOSION PROOF TYPE Suitable for non-conductive material and middle-size tank. Model No. Probe material Suitable for non-conductive material and big tank. Suitable for non-conductive material and big tank. EB1731 Hi-Temp Wire Probe Weight material Ambient Temperature Operating Temperature Measuring Range Tensile strength Operation voltage Output current Connection Weight Operating pressure
Open the catalog to page 12EXPLOSION PROOF TYPE EB1740 --- PVDF Coating EB1742 --- PP Coating EB1743 --- FEP Coating Suitable for conductive/ corrosive material and middle-size tank. Model No. Probe material EB1752 --- PP Coating EB1753 --- FEP Coating Suitable for conductive/ corrosive material and big tank.(weight can not be fixed at the bottom of tank) EB1752/53 Anti-Corrosion Wire Probe Weight material Ambient Temperature Operating Temperature Tensile strength Operation voltage Measuring Range Output current Connection Weight Operating pressure
Open the catalog to page 13ORDER INFORMATION Probe Length (unit: mm) -1 % Use English letter as first code for probe length over 10m. * Tolerance of the total product length is ± 5mm * Characteristics, specifications and dimensions are subject to change without notice. * Please contact your nearest distributing office for further informations.
Open the catalog to page 14All FineTek Co. catalogs and technical brochures
-
EFX By-Pass Level Transmitter
34 Pages
-
EPD Electromagnetic Flow Meter
28 Pages
-
Tuning Fork Level Switch
32 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Ultrasonic Level Transmitter
8 Pages
-
Temperature Transmitter
5 Pages
-
Thermocouple
12 Pages
-
Vibrating point level switch
14 Pages
-
SA Capacitance Level Switch
18 Pages
-
SE Rotary Paddle Level Switch
15 Pages
-
EC Pressure Level Transmitter
12 Pages
-
SQ Pressure Switch
12 Pages
-
SD Optical Level Switch
2 Pages
-
FF Side Mounting Float Switch
15 Pages
-
FC/FD Mini Float Level Switch
28 Pages
-
RF-Admittance Level Switch
11 Pages
-
Optical Level Switch
13 Pages
-
Rotary Paddle Level Switch
15 Pages
-
Magnetic Float Level Transmitter
14 Pages
-
RF-Admittance Level Transmitter
15 Pages
-
Capacitance Level Switch
18 Pages
-
Vibrating Probe Level Switch
10 Pages
-
Pressure Level Transmitter
12 Pages
-
Magnetic Float Level Switch
24 Pages
-
EF By-Pass Level Transmitter
23 Pages
-
Air Hammer/Pneumatic Vibrator
16 Pages
-
Mini Float Level Switch
28 Pages
-
Pressure Switch
12 Pages
-
PID+Fuzzy Temperature Controller
23 Pages
-
Cable Float Level Switch
12 Pages
-
Side Mounting Float Switch
15 Pages