Fincoil SVC - Fincoil - #4

/ 4


catalogue search
P. 01
P. 02
P. 03
P. 04
Pages:


See other catalogues for Fincoil
You may also be interested in

Condenser, Air heater, Cooler, Dry cooler, Radiator


Text version of the page
Untitled table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:8.00pt "Arial", sans-serif; } .font5 { font:10.00pt "Arial", sans-serif; } .font6 { font:18.00pt "Arial", sans-serif; } .font7 { font:32.00pt "Tahoma", sans-serif; } .font8 { font:8.00pt "Times New Roman", serif; } .font9 { font:21.00pt "Times New Roman", serif; } .font10 { font:23.00pt "Times New Roman", serif; } SVC Connection examples 1) Single-circuit condenser e.g. SCA-6-4-914-950-3/400/50-H is equipped with SVC-I-P1-BPA for fan speed control. The condensing pressure is kept constant with PI-control. SUPPLY 3/400 V/50 Hz 1 CONNECTIONS ON THE FREQUENCY CONVERTER c. , hl w w |—^ - Signal cable shield 1 cr^D External reference 1: 0...10 V or 0(4)...20 mA Analog input circuit common Reference voltage 10 VDC Actual signal 1: 0...10 V or 0(4)...20 mA Analog input circuit common |j1-dip| .------ 0-10 V or 4-20 mA ECU ECI 2 3 i______\/ I_ 4 4-20 mA 5 6 SVC-I-P1-BPA SVC-I-T-BPA SVC-I-ECU/I-BPA A01 7 A02 8 agnd 9 Auxiliary voltage output +24 VDC Common for DI return signals Digital input common for all Start / stop +24 V 10 gnd 11 dcom 12 1) START / STOP - running permit - service rolling 1) Without the control motors shall rotate continuosly at least min. speed D11 13 D12 14 NOTE! IF BPA-OPTION IS SELECTED THEN RELAY 01 IS RESERVES TO BPA-FUNCTION D13 15 D14 16 D15 17 D16 18 R01C 19 Ready = > 19 connected to 21 R01A 20 R01B 21 The desired value of the condensing pressure is set via panel. The operating range of the pressure transmitter is -1...+34 bar (gauge), 4...20 mA. The pressure trans-mitter with default settings is ready-fitted at the factory. The converter supplies electricity to the fan motors only if the 'Start' signal is active. The alarm, by-pass and operational status of the unit can be determined volt-free contacts. The unit maintains the set condens­ing pressure value by controlling the fan speed accord-ing to operational conditions. P1 = pressure transmitter Start/Stop = unit activation The external signal connection (ECU, ECI on the diagram) is not needed on this example. Running = > 22 connected to 24 R02C 22 R02A 23 R02B 24 Fault = > 25 connected to 27 R03C 25 R03A 26 CONNECTIONS ON TERMINAL BLOCKS Alarm, circuit breakers Alarm, frequency converter by-passed, only when BPA-option R03B 27 The wiring between the unit and the fan motors is ready fitted at the factory *) Link between 6 and 11 not needed with ECU and ECI. 2) The dry cooler, e.g. SCAG-14-10-950-3/400/50-H, is provided with a temperature transmitter (T) instead of pressure transmitter (P1). The sensing element of this transmitter measures the outlet tem­perature of the liquid. The control parameters are set according to the required project conditions and specified dry cooler settings. The external signal connection (ECU, ECI on the diagram) is not needed in this example. Type designation is SVC-I-T-BPA. 3) In remote control the frequency converter receives the direct fan frequency value as a voltage (ECU) or current signal (ECI). In this case pressure (P1) or temperature transmitters (T) are not fitted to the dry cooler. If the control is from voltage signal 0...10 V, the type designation is SVC-I-ECU-BPA. firLCoil Fincoil-teollisuus Oy Ansatie 3 FI-01740 Vantaa, Finland Tel. +358-9-894 41 Fax +358-9-8944 318 www.fincoil.fi Subject to changes without prior notice. 4 12/2006

pageCatalog pdf di En 2012-05-19-11