ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik - #1

/ 20


catalogue search
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 01
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 02
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 03
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 04
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 05
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 06
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 07
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 08
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 09
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 10
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 11
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 12
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 13
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 14
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 15
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 16
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 17
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 18
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 19
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik
P. 20
Pages:
ILVT - Safety light curtains with Blanking features_category 2 Operating Instructions: Programming devices for ILVT - Fiessler Elektronik


See other catalogues for Fiessler Elektronik

Text version of the page
Programming and control units
for Light curtains BLCT / ILCT / BLVT / ILVT
BLPG BPSG
IESSLER
L E K T R O N I K
Operating manual
BLPG
Programming unit for
light curtain blanking functions
29 28 27 26
25
23
s3
20 19
I E„°SM- |blvt+|
Mo.yea of con
17
24v
21
EDM-
I s1
Auflösung kennzeichnen!
AI
Nr/Baujahr Temp. Sihulzarl Versorgung
temp.
-10... + 55 "C 24 VDC -10% + 213 %
22 / 42 mm ^
29 / 56 mm #
aktiv
O
E LE KTR O N IK
Kaslellslr.9 73734 Esslingen
Germany
Allenlion Couper rallmenlalbri !
(S
BPSG
Programming unit for
light curtain blanking functions
and switching unit
s0000000000000000s
29 I 28 I 27 J 26 25
24
s2
0 [c
23 22 s3 I pe
2H 20 19 18 17
iPfr I ms"" Iblvt+ 0v I 24v I
Al
I s1
__________„ ..innzeichnen!
deleclion to he indicaled!
Nr/Baujahr Mo/yea otconslrucion .................................
Ansprechzeil response ttte 6 mSs+ BWS/ ESPE
Temp. temp. -10... + 55 "C
5:hulzar1 enclosure nttng IP 20
Versorgung supply voltiae 230 VAC -15% +10 %, 50Hz
Konlaklbel. contact ton.. 2 A, 250 VAC
Achtung Vor Abziehen der Klemmleiste Netzspannung abschalten!
14 / 30 mm 4*
+-
22 / 42 mm ^
29 / 56 mm 0
4-
K-
*-
I E L E K T R O N IK
Kaslellslr.9 73734 Esslingen
aktiv
o
OSSD1 OSSD2
SK
11
230V 115V 1 i 2
2J3V
6 \ 7 1 M 9 I 10
iT
14 I 15 I 16 I
13
<S0000000000000000S
Features:
- storage one of 11 blanking modes in the light grid BLCT, ILCT, BLVT or ILVT
storage up to 5 blanking modes in the light grid BLCT, ILCT, BLVT or ILVT and recall via a selector switch again
- storage up to 5 operation modes in the switching units PLSG3 or PLSG3K and recalled with a selector switch again. e.g. cycle control, Muting mode or safety mode (in each case with and without restart interlock, with and without contactor control)
- storage up to 5 modes of operation in the switching units PLSG3 or PLSG3K and at the same time can be stored up to 5 blanking modes in the light grids BLCT, ILCT, BLVT or ILVT and recall via a selector switch again
BLCT / ILCT
BLVT / ILVT
CONTENTS:
BG SÈ [bel Safety instructions A
Approved 'UV —^ LISTED \-S ' L
optional . .. .
Application notes Electric connection Technical specifications
Fiessler Elektronik Kastellstr. 9 D 73734 Esslingen
Phone: +49(0)711 / 91 96 97-0 Internet: http://www.fiessler.de Fax: +49(0)711 / 91 96 97-50 eMail: info@fiessler.de

pageCatalog pdf di En 2012-05-22-29