| | | Product data sheet Sheet No.: 1.602.01 - Rev: A Date: April 2006 | | |
| | | FieldQ | | |
| | | |
| | | |
| | | FieldQ Actuator Torque | | |
| | | |
| | | Double Acting Actuators - Nm & in.lb. | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | Torque INm) | | | | tvpe | Supply Pressure f bar q| | | | | | | 3 | 3.5 | 4 | 4.S | 5 | 5.5 | 6 | 6.5 | 7 | 8 | | | | QD 40 | | | | | | | | | | | | | | | QD 65 | 25 | 38 | 45 | 51 | 58 | 64 | 71 | 77 | 84 | 90 | 104 | | | | | 38 | | | 76 | | 95 | 105 | | 124 | | 153 | | | | QD 150 | 60 | 91 | 106 | 122 | 137 | 153 | 168 | 183 | 199 | 214 | 245 | | | | | 62 | 124 | | 167 | 188 | 209 | 230 | 251 | 272 | 293 | 335 | | | | OD 350 | 143 | 216 | 253 | 290 | 326 | 363 | 400 | 436 | 473 | 510 | 583 | | | | | | | | | | | | | | | | | | | OD 950 | | | | | 828 | | | | | | | | | | OD ■SCO | 600 | 907 | 1081 | 1214 | 1388 | 1522 | 1678 | 1829 | 1983 | 2137 | 2444 | | | | | | | | | | | | | | | | | | | |
| | | |
| | | | | | | | | | | | | | | | | | | | | Toraue fin.lb.l | | | | type | Supp | (■[.'"-'SSUrí. | psiq] | | | | | | | | | | | | | | | | | | | OD 40 | 153 | 231 | 257 | 309 | 335 | 361 | 387 | 413 | 465 | 518 | 622 | | | | OD 65 | 233 | 352 | | | | 550 | 590 | 630 | | 789 | | | | | OD 100 | 344 | 520 | 579 | 696 | 755 | 814 | 873 | 931 | 1049 | 1165 | 1401 | | | | | | | | | | 1303 | | | | | | | | | OD 200 | 754 | 1140 | 1269 | 1526 | 1655 | 1784 | 1913 | 2041 | .-:■■■■ | 2556 | .: ■:'■ | | | | | 1310 | 1981 | 2205 | 2652 | 2876 | 3100 | .:■■:■'.-. | 3547 | 3994 | 4442 | \,/;.w | | | | OD 600 | | | 3747 | 4507 | 4387 | 5267 | 5347 | 6028 | 6788 | 75¿S | 9069 | | | | OD 950 | 3323 | 5025 | 5593 | 6727 | 7295 | 7862 | 8430 | | 10132 | ■':■'.-■ | 13537 | | | | OD 1600 | :;1f!.i | ij« 7 | :;:>¡:i | r'.2' | 12059 | 12998 | 13936 | -■187': | li; | 18626 | :■:-:■:■ | | | | | | | | | | | | | | | | | | | |
| | | |
| | | Double acting torque diagram START | | |
| | | |
| | | Note: 1. Actuator torques are guaranteed minimum torque values. Emerson Process Management recommends that the valve manufacturer supply the maximum required torque values (Including any adjustments or suggested safety factors for valve service conditions or application!. Additionally, the valve manufacturer must identify at which position(s) and direction; s j :::! relation [Counter Cioc-¡ Wis a or Clock Wise) these 'iiiixrnum requirements occur. 2. If in doubt, or you require any [assistance with sizing actuators, do not hesitate to contact your nearest Emerson's Valve Automation Division representative. ♦ EMERSON | | |
| | | |
| | | Process Management | | |
| | | |
| | | | | | | | | | | | | | | | | |