Methanol fuel cell test system - Fideris - #1

/ 2


catalogue search
Methanol fuel cell test system - Fideris
P. 01
Methanol fuel cell test system - Fideris
P. 02
Pages:
Methanol fuel cell test system - Fideris


See other catalogues for Fideris

Text version of the page
Air Mass Flow Controller Full Scale Standard Liters Per Minute. Specified full scale between 0.05 slpm through 10 slpm. Control is from 2% to 100% of specified full scale. Model Number Creation Model Number: MTK-10-E-AA-TTTTT4-1600 Load Current & Voltage Limit 0 = no load D = 50A, 5V A = 5A, 5V E = 50A, 10V B = 5A, 10V F = 50A, 20V C = 5A, 20V Air Supply Backpressure and Knockout 0 = No air channel installed A = No backpressure, No tailgas knockout B = No backpressure With tailgas knockout C = With backpressure, With tailgas knockout H2O and MeOH Makeup and Backpressure A = No H2O makeup, No MeOH makeup, No backpressure B = No H2O makeup, No MeOH makeup, With backpressure C = No H2O makeup, With MeOH makeup, No backpressure D = No H2O makeup, With MeOH makeup, With backpressure E = With H2O makeup, No MeOH makeup, No backpressure F = With H2O makeup, No MeOH makeup, With backpressure G = With H2O makeup, With MeOH makeup, No backpressure H = With H2O makeup, With MeOH makeup, With backpressure Five (5) Auxiliary Input / Outputs A = AC switch output 120VAC @ 3.5 amps B = AC switch output 240VAC @ 3.5 amps C = DC switch output 60VDC @ 3.5 amps D = Dry switch output 100 VDC @ 0.5 Amp resistive E = Dry switch output 200 VDC @ 1 Amp resistive F = AC/DC present input 90-140V G = AC/DC present input 180-280V H = DC present input 3-32V I = AC/DC present input 35-60V J = Contact closure input for dry switch K = 0 to 5 VDC analog voltage output L = -5 to 5 VDC analog voltage output M = 0 to 10 VDC analog voltage output N = -10 to 10 VDC analog voltage output O = 4 to 20 mA analog current output P = 0 to 20 mA analog current output Q = 0 to 50 mV analog voltage input Methanol Test Kit Series } For sales, literature, or technical information regarding the Fideris brand Fuel Cell Test Systems, please contact: Specifications Front Panel Displays Fuel Cell Voltage: 3-1/2 digit LCD backlit display Fuel Cell Current: 3-1/2 digit LCD backlit display Regulated Air Inlet Pressure: 0-200 psi analog gauge Front Panel Connections (all mating connectors provided) MeOH Feed from Reservoir: 3/8” Swagelok ® quick connect MeOH Return to Reservoir: 1/4” Swagelok ® quick connect MeOH Reservoir Level Switch: LEMO® (cable provided) Air Feed to Fuel Cell: 1/4” Swagelok ® quick connect Air Return from Fuel Cell: 1/4” Swagelok ® quick connect MeOH Feed to Fuel Cell: 1/4” Swagelok ® quick connect MeOH Return from Fuel Cell: 1/4” Swagelok ® quick connect Recirculation Methanol-H2O Temperature: Mini Type K (thermocouple provided) Load Connections: Banana jack, screw, or bolt-on Fuel Cell Voltage: LEMO® (3’ mating cable provided) Fuel Cell Temperature Input: Mini Type K (thermocouple provided) Auxiliary I/O: LEMO® (3’ mating cable provided) Auxiliary Temperature Input: Mini Type K thermocouple (mating connector provided) Switched Receptacle Output: IEC-320 output (mating cord provided) Back Panel Connections Power Inlet: IEC-320 (mating cord provided) Reactant Air Inlet: 1/4” Swagelok® Tail Gas Discharge: 1/4” Swagelok ® Water Discharge (optional): 1/8” Swagelok ® Control Air Input (if required by options): 1/4” FNPT Water Make-up (optional): 1/8” Swagelok ® MeOH Make-up (optional): 1/8” Swagelok ® RS-485 Communication In/Out: DB-9 Hardwire E-Stop Input: 4 pin connector (jumpered mate, mating housing & sockets provided) Hardwire E-Stop Output: 4 pin connector (mating housing & pins provided) Safestate Remote Input/Output: 7 pin connector (jumpered mate provided) MeOH-H2O Recirculation System Flow Control: Computer controlled gear pump Range of Control: 48 to 1600 milliliters per minute standard Maximum Temperature: 95° C Heating Capacity: 400 Watts Cooling Capacity: 350 Watts Maximum Pressure Created: 45 psi Maximum Case Pressure: 80 psi Reservoir Capacity: 1 Liter Fuel Pressure Control: Optional. Computer controlled MeOH Make-up (optional) Flow Control: Computer controlled piston pump Range of Control: 0-1 milliliter per minute standard H2O Make-up (optional) Flow Control: Computer controlled piston pump Range of Control: 0-1 milliliter per minute standard Gas Handling Air Flow Control: Mass Flow Controller Range of Control: 0.2 - 10 liters per minute standard Air Input Pressure Range: 80-200 psi Tail Gas Phase Separator: Optional Tail Gas Backpressure Control: Optional. Computer controlled Electronic Load Type: MOSFET variable resistance loadbank Current Measurement: Panel shunt Maximum Current Rating: 5 Amp or 50 Amp Maximum Voltage Rating: 5, 10, or 20 Volts Maximum Power Dissipation: 150 Watts Nominal Short Circuit Resistance: <5.0 milliohms Corrosion Protection: All critical components gold plated Electrical Requirements Voltage: 120 / 230-240 VAC (field changable) Frequency: 50 - 60 Hz Power Consumption: 800 Watts Installation Requirements Clearance for Operation: Back: 6”, RH: 6”, LH: 12”, Top: 0” Physical Characteristics Dimensions: 29” D; 21.5” H; 12” W System Weight: 50-80 lbs. (depending upon options) Operating Environment: 40° to 100° Fahrenheit, 85% RH Cabinet Rating: Indoor Cell Heater Switched Receptacle Voltage/Frequency: Same as main power input Max. Current: 3.5 Amps Control Input: Type K thermocouple Specifications subject to change. This equipment amy be protected by one or more of the following patents: U.S. Patent # 5,512,831, 6,324,042, 6,383,671, 6,792,320. Additional patents pending. Registered trademarks: Swagelok® - Swagelok Co., LEMO® - LEMO U.S.A. Inc. Fuel Cell Test System, FCTS, Direct Methanol Test Kit, Methanol Test Kit, MTK, FCPower, Fideris, the Fideris logo and the TesSol logo are trademarks of TesSol, Incorporated. Copyright 2008 TesSol, Incorporated Working in the Field of Direct Methanol Fuel Cells? MODEL FCTSTM MTKTM FUEL CELL TEST SYSTEMTM DIRECT METHANOL TEST KITTM The Clock Is Ticking Away... Do You Have The Time And Money to Spend Building Test Equipment? Invest Your Time in Fuel Cell Ideas and Research... The MTKTM Series Test System from FiderisTM . A Complete Direct Methanol Test System in One Affordable Package! +Control Software +Electronic Load +Auxiliary Input / Output +Fuel Cell Heater Control +MeOH-H2O Heating and Cooling +MeOH-H2O Recirculation System +Mass Flow Control of Reactant Air +Methanol and Water Makeup Metering Pumps (optional) +Liquid and Reactant Gas Backpressure Control (optional) Fideris Direct Methanol Fuel Cell Test Equipment Visit us at www.fideris.com NOT in Developing Test Equipment. R = 0 to 100 mV analog voltage input S = 0 to 1 VDC analog voltage input T = 0 to 5 VDC analog voltage input U = 0 to 10 VDC analog voltage input V = -5 to 5 VDC analog voltage input W = -10 to 10 VDC analog voltage input X = 0 to 20 mA analog current input Y = 4 to 20 mA analog current input Z = 0 to 5 A analog current input 1 = 28 to 140 VAC analog voltage input 2 = 28 to 280 VAC analog voltage input 3 = Type J input thermocouple 4 = Type K input thermocouple 5 = Type R input thermocouple 6 = Type T input thermocouple 7 = AD590 temperature probe input 8 = RTD input - = No I/O module installed Recirculation Pump Maximum Flow Rate (mL/min) October 2008 Auxiliary Temperature Input Type (ID = 3,4,5,or 6 from table below) 0 = No Recirculation 1600 = 48 to 1600 mL/min 85 = 2.6 to 85 mL/min 3200 = 96 to 3200 mL/min 210 = 6.3 to 210 mL/min 4700 = 141 to 4700 mL/min 420 = 12.6 to 420 mL/min TesSol = Testing Solutions e-mail: info@tessol-inc.com Website: www.fideris.com TesSol, Inc. 1315 SE Grace Ave Suite 130 Battle Ground, Washington 98604 USA Phone: 360.687.1393 • Fax: 360.687.8251

pageCatalog pdf di En 2012-05-21-21