fibroMAT Heavy-load positioning tables - 1

fibroMAT Heavy-load positioning tables data sheet collection

Open the catalog to page 1
fibroMAT Heavy-load positioning tables - 2

FIBROMAT® AT.0800 Dimensions of FIBROMAT® AT.0800 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.0800 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 320 mm Extended by 200 mm (not combinable with standard indexing...

Open the catalog to page 2
fibroMAT Heavy-load positioning tables - 3

FIBROMAT® AT.0800 Technical data for FIBROMAT® AT.0800 Maximum axial runout of the table top 0.05 mm Maximum runout of the centre hole Weight 0.05 mm FIBROMAT AT.0800 Gear motor Indexing unit Indexing times for FIBROMAT® AT.0800 AT.0800 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.0800 Perm. transport load on table top horizontal Perm. superstructure diameter Perm....

Open the catalog to page 3
fibroMAT Heavy-load positioning tables - 4

FIBROMAT® AT.1000 Dimensions of FIBROMAT® AT.1000 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.1000 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 520 mm Extended by 200 mm (not combinable with standard indexing...

Open the catalog to page 4
fibroMAT Heavy-load positioning tables - 5

FIBROMAT® AT.1000 Technical data for FIBROMAT® AT.1000 Maximum axial runout of the table top 0.05 mm Maximum runout of the centre hole Weight 0.05 mm FIBROMAT AT.1000 Gear motor Indexing unit Indexing times for FIBROMAT® AT.1000 AT.1000 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.1000 Perm. transport load on table top horizontal Perm. superstructure diameter Perm....

Open the catalog to page 5
fibroMAT Heavy-load positioning tables - 6

FIBROMAT® AT.1250 Dimensions of FIBROMAT® AT.1250 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.1250 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 770 mm Extended by 200 mm (not combinable with standard indexing...

Open the catalog to page 6
fibroMAT Heavy-load positioning tables - 7

FIBROMAT® AT.1250 Technical data for FIBROMAT® AT.1250 Maximum axial runout of the table top 0.07 mm Maximum runout of the centre hole Weight 0.07 mm FIBROMAT AT.1250 Gear motor Indexing unit Indexing times for FIBROMAT® AT.1250 AT.1250 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.1250 Perm. transport load on table top horizontal Perm. superstructure diameter Perm....

Open the catalog to page 7
fibroMAT Heavy-load positioning tables - 8

FIBROMAT® AT.1600 Dimensions of FIBROMAT® AT.1600 (Drive arrangement 180° with one drive; for other drive arrangements, diagrams or CAD data are available) Technical data for FIBROMAT AT.1600 ® 1 drive without motor 1 drive with motor 1 drive with motor 1 drive with motor 2 drives without motor 2 drives with motor 2 drives with motor 2 drives with motor Drive arrangement Drive motor See pictures above Special design Without indexing unit With indexing unit for division XX, symmetrical arrangement Special division Centre hole Ø 1,000 mm Extended by 200 mm (not combinable with standard...

Open the catalog to page 8
fibroMAT Heavy-load positioning tables - 9

FIBROMAT® AT.1600 Technical data for FIBROMAT® AT.1600 Maximum axial runout of the table top 0.1 mm Maximum runout of the centre hole Weight 0.1 mm FIBROMAT AT.1600 Gear motor Indexing unit Indexing times for FIBROMAT® AT.1600 AT.1600 with one drive 45° ts in s J in kgm2 90° ts in s J in kgm2 180° ts in s J in kgm2 The specified switching times do not include: Regulation time of 0.1 sec, indexing time of 0.3 sec. Further angels and indexing times can be calculated for you. Load data for FIBROMAT® AT.1600 Perm. transport load on table top horizontal Perm. superstructure diameter Perm. force...