SAFETY RELAYS - FIBER - #9

/ 10


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
Pages:


See other catalogues for FIBER

Text version of the page
Simultaneity module (Two-hand control) (45 mm)
E62 F85
0
o o
■H
>
Compliant to directives:
89/392/CEE-91/368/CEE-93/44/CEE-93/68CEE
Conform to standards: EN292-2; EN574; EN60204-1 IEC249
■H 4-
Safety Class: III A
Technical Data
Applications
Features
Supply voltage
24 Vac/Vdc ; 48, 115, 230 Vac ; 50 and 60 Hz
Supply tolerance
Vac ±15% ; Vdc +15% - 10%
Power consumption
< 3 VA ; 3W
Voltage / current in the input channels
24 Vdc / 35 mA
Simultaneity monitoring
0.5 s
Response time
30 ms
Function
F85
Contacts rating
6 (4) A 250 Vac / 4 A 24 Vdc
Expected life
electrical: 105 operations, cos 9 1 mechanical: 107 operations
Indications
LED ON
Insulation voltage
2.5 kV / 50 Hz
Temperature range
operating:-10°C +55°C storage: -30°C +80°C
Mounting
35 mm DIN rail (EN50022) 2 M4 screws fixing
Connections
screws
(rigid cables 4 mm2, flexible cables 2.5 mm2)
Protections
housing: IP40 terminals: IP20
Housing
fiberglass reinforced polycarbonate, RAL 7035
Overall dimensions
45 x 75 x 110 mm
Weight
320 g
Approvals
c(|Jl)iis listed (File no. E103319)
C€_
Declaration of conformity
Rohs (Directive 2002/95/CE)
Safety check for manual operation of machines
Safety Class: III A
Redundant circuits with forced contact relays with self-monitoring
Automatic check at each opening/closing of the safety circuit relays Possibility to extend the contacts with exter­nal self-monitoring relays Input for machine contact enabling Built-in electronic fuse Output with two N.O. safety contacts
Diagram
P3~H~23"K
[]
Channel 1
+
B0
Channel 2
A2 - X2 H X1 HS23 HS24 h
14 24
Connection and operating diagrams
P2 I I I
X1-X2
S13-S14
ce
S21-S22
In order to avoid welding of the output contacts, position a delayed fuse max. 4A or a quick fu­se max. 6.3A upstream the contacts.
(K1-K2)
13-14 / 23-24
s ^_^
1.8

pageCatalog pdf di En 2012-05-20-14