Safety devices

Operation

X1 - X2 terminals must be permanently short circuited with a jumper.When the device is supplied the ON LED lights up.The simultaneous operation of P1 and P2 push-buttons, withina max.time of 0.5 s, energises K1 - K2 relays and closes 13-14 and 23-24 P1 safety contacts.When one of thepush-buttons is released, the relays de-energise and the output contacts open.Cycle repetition (relays energising) is possible only by releasing and then pressing both push-buttons again.If and P2 are pressed with a timeinterval greater than 0.5 s, the energising of K1 - K2 relays will not be enabled and the contacts will not close.To repeat the cycle, both push-buttons must be released and then pressed again. Normally-closed contacts from the monitored machine can be connected to X1 - X2 terminals.These contactsenable operation of the two-hand device only under specific work conditions:closed guards, safety devices in place, etc.Those same terminals can be used to check proper operation of external contactors used to increase the number of contacts or their rating.

Connection diagram External contactors check

A1 13 23S14S13X2X1 K1K3K4K2 K3K4 A2 14S23S24 24 P2 P1 K3K4 Connection to increase the number of contacts or their rating with the use of external feedback contactors.Correct operation of the external contactors is monitored by the contacts connected to X1 - X2 terminals of the feedback circuit.

Overall dimensions

4.5 60 75 110 45

Ordering code

E62.__.V0.85.V0

Voltage

0TB3B4BJ 24 Vac / Vdc 48 Vac115 Vac230 Vac

Other versions on request.