ELECTRONIC TIMERS - FIBER - #9

/ 22


catalogue search
P. 01
P. 02
P. 03
P. 04
P. 05
P. 06
P. 07
P. 08
P. 09
P. 10
P. 11
P. 12
P. 13
P. 14
P. 15
P. 16
P. 17
P. 18
P. 19
P. 20
P. 21
P. 22
Pages:


See other catalogues for FIBER
You may also be interested in

Monitoring relay, AC motor, DC motor, Electronic relay, Switch


Text version of the page
Electronic Timers (22,5 mm)
E21 F05, E21 F06
Single-voltage Multi-voltage Single-range Single-function
E ■H H
Technical Data
Connection and operating diagrams
F05 - Delay on de-energisation. (Supply off)1 contact
Supply voltage
12Vdc (F05); 24Vdc (F05, F06);
multi-voltage:
24, 110, 220...240Vac (F06)
Supply tolerance ± 10%
Power consumption
0,5VA a 12V; 1VA a 24V; 8VA a 240V
Operating factor
100%
Timing ranges
1, 3, 6, 12, 30, 60, 120 s; 3, 6, 12, 30, 60 min
Minimum set time
1/50 of time full-scale
Repetition accuracy at constant parameters
± 1% of time full-scale value
Functions
F05, F06
Contacts rating
5A 250Vac / 24Vdc (carico resistivo)
Operating life
electrical: 2 x 105 operations, cos 9 1 mechanical: 2 x 107 operation
Indication led ON
Insulation voltage
2KV/50Hz
Temperature range
operating: -10°C +55°C storage: -30°C +80°C
Mounting
35 mm DIN rail(EN50022)
Connections
screws
Protections
housing: IP30 terminalsi: IP20
Housing
fiberglass reinforced polycarbonate
Overall dimensions
22,5 x 78,5 x 105 mm
Weight
125 g
Approvals
Declaration of conformity
ROHS (Directive 2002/95/CE)
u
■H
c o ī_
■H
u
0) H LU
> 1 c
S
R
At
At: with full-scale value up to 3 min = 0,2 s with full-scale value above 3 min = 0,7 s
F06 - Delay on de-enegisation. (Supply off) 2 contacts
> 1s
S
R1-R2
At
At: with full-scale value up to 3 min = 0,2 s with full-scale value above 3 min = 0,7 s
Overall dimensions
oooc
c
0
78.5
c
oooc
22.5
5
100
E21.__.__.__.V0
Function
Full-scale value
Voltage
SB
1 s
ME
3 min
SE
3 s
MG
6 min
SG
6 s
MJ
12 min
SJ
12 s
MK
30 min
SK
30 s
HB
60 min
MB
60 s
MD
120 s
C1 12 Vdc (F05) C2 24 Vdc (F05-F06) BM Multi-voltage (F06)
05 06
ce
In the multi-voltage E21 F06, the supply vol­tage, can be selected by means of a jumper, with side access.
Other versions on request.
4.8

pageCatalog pdf di En 2012-05-22-29