E21 F10, E21 F12

ELECTRONIC TIMERS - 11607 Electronic Timer(22,5 mm)Star-Delta starterMulti-voltageDual-range Single-function

Technical Data Connection and operating diagrams Supply voltage multi-voltage 24 Vdc - 24, 110, 220...240 Vac
L F10 Supply tolerance ±10% Power consumption
A1S 15 25 1 VA at 24 V;8 VA at 240 V
SR2 R1R2 Operating factor
R1 t 100%
t Timing range
A21828 16 26 Dual-range:30 and 60 seconds
N Minimum set time
(selectable) 1/20 of time range value
Electronic Timers L F12 Repetition accuracy at constant parameters ±1% of time full-scale value Reset time
A1S 15 25 SR2R1t
R1R2 t Function F10, F12 Contacts rating
A21828 16 26 5 A 250 Vac / 24 Vdc (resistive)
N Operating life
(selectable) electrical:10
5 operations, cos
7 Ï• 1mechanical:2 x 10 operations Overall dimensions Indication LED , LED ∆ Insulation voltage 2kV / 50Hz Temperature range operating:-10°C +55°C storage:-30°C +80°C Mounting
75 78.5 35 mm DIN Rail (EN50022) Connections screws Protections housing:IP30 terminals:IP20
1005 22.5 Housing fiberglass reinforced polycarbonate Dimensions 22,5 x 78,5 x 105 mm Ordering code Weight 125 g ApprovalsDeclaration of conformity

E21.BM.S3.__.V0

ROHS (Directive 2002/95/CE)
Function

1012

The following parameters can be selected th-rough side access:time range value and ∆
t va-lue by means of dip switches;supply voltage bymeans of jumper Other versions on request.

4.21


pageCatalog pdf di En 2012-05-22-29