| 1) The proportional directional control valve MPYE requires these characteristic values 2) Note stroke reduction 3) The drive DGPL-....-KF-... exclusively is permitted for positioning 4) Characteristic of the displacement encoder 5) At 6 bar, horizontal mounting position, DPGIL-XX-1250,1000 mm positioning travel at min./max. load 6) At 6 bar, horizontal mounting position, DPGIL-XX-1250,100 mm positioning travel at min./max. load 7) The drives can be positioned with the described characteristics up to the stroke reduction. If the stroke reduction is exceeded, the time needed to reach the target position can increase considerably. The PtTool software can be used to calculate further positioning times www.festo.com. 8) In relation to the maximum stroke of the drive, but never more than 20 mm 9) Thestrokereductionmustbecomplied with oneach sideofthedrive.Themaximum positionablestrokeis therefore:stroke-2 xstrokereduction |