FERROFLO
Lubricated Thermoplastics
Property
Unit
ASTM Method
SPS05PK02NA
SPS05PK03NA
Tensile Strength @ 73'F
psi
D638
3,200
3,700
Elongation at Break
%
D638
30
5
Flexural Strength @ 73'F
psi
D790
4,700
5,200
Flexural Modulus (tangent)
psi x 105
D790
2.7
3.4
Flexural Modulus (1% secant)
psi x 105
D790
2.5
3.2
Izod Impact @ 73'F Notched
ft-lb/in
D256(1)
2.0
1.0
(1/2" x 1/8" bar)
Izod Impact @ 73'F Unnotched
ft-lb/in
D256
5.0
2.0
(1/2" x 1/8" bar)
Gardener Impact @ 73'F
in-lb
16.0
2.0
(Mean Failure Energy)
Heat Deflection Temperature, 264 psi
°F
D648
155
165
Heat Deflection Temperature, 66 psi
'F
D648
175
185
Specific Gravity
D792
1.03
1.03
Hardness, Shore "D"
D2240
72
73
Melt Flow
g/10 min
D 1238(2)
35
30
Lubricant Content
%
-(3)
5
5
Mold Shrinkage
in/in
.007
.007
(1) Method A
(2) Condition 23(TC/3.8Kg
(3) PRAXIS PNMR
SPS20PK with higher lubricant loading, for usage as a concentrate, is available.
Mold shrinkage is intended as a guide only, as specific shrinkage is affected by part design, mold design and molding conditions.
Filled and Reinforced Plastics Division
Ferro Corporation 5001 O'Hara Drive Evansville, IN 47711 Tel: (812)435-2100 Fax: (812) 435-2113
Disclaimer And Limitation of Liability
The information contained in this data sheet has been developed through the application of accepted laboratory practice and is believed to be reliable. Since the conditions of application and use of our products are beyond our control, no warranty or representation is expressed or implied regarding accuracy of the information, the results to be obtained from the use of the product, or that such use will not infringe on any patent.
This information is furnished with the express conditions that the user will evaluate it through testing and determine the suitability of the product. Ferro Corporation will not be liable for any injury or damage arising from application of this information. FERRO'S WARRANTY IS SET FORTH IN ITS STANDARD TERMS & CONDITION OF SALE AND IS LIMITED TO PRODUCT REPLACEMENT OR PURCHASE PRICE REFUND. FERRO DISCLAIMS ANY WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR USE.
FERRO.

pageCatalog pdf di En 2012-05-19-09