catalogue search
|
You may also be interested in
Moisture meter, Cam switch, Protection relay, Power capacitor, Load-break switch
Text version of the page
Untitled
table.main {}
tr.row {}
td.cell {}
div.block {}
div.paragraph {}
.font0 { font:6.00pt "Arial", sans-serif; }
.font1 { font:7.00pt "Arial", sans-serif; }
.font2 { font:8.00pt "Arial", sans-serif; }
.font3 { font:16.00pt "Arial", sans-serif; }
.font4 { font:17.00pt "Arial", sans-serif; }
.font5 { font:34.50pt "Arial", sans-serif; }
.font6 { font:5.00pt "Arial Black", sans-serif; }
.font7 { font:12.00pt "Georgia", serif; }
.font8 { font:14.00pt "Georgia", serif; }
.font9 { font:9.00pt "Impact", sans-serif; }
.font10 { font:15.00pt "Lucida Sans Unicode", sans-serif; }
.font11 { font:7.00pt "Palatino Linotype", serif; }
.font12 { font:13.00pt "Trebuchet MS", sans-serif; }
.font13 { font:28.00pt "Trebuchet MS", sans-serif; }
.font14 { font:8.00pt "Verdana", sans-serif; }
.font15 { font:9.00pt "Verdana", sans-serif; }
.font16 { font:10.00pt "Verdana", sans-serif; }
LV. CIRCUIT BREAKERS
Calculation of short circuit at any point of Ihe network:
The following tables allow fast calculation of the short circuit curreni at any point in the network, ïf short circuit currenl at network side, cable section, type and length are known
Readlng of diagram:
Cable section and short circuit current on network side is marked in the table Cable length is found on ihe cable section row. Cable length and shon circuit curreni at network side are intersected and marked. This value gives the short circuit current to occur at the end of the cable
380 V
■115 V
Cable
(mm2) Cu
Al
Câbla length (m)
1.5
2,5
—
—
1
—
—
2
—
3
2.5
4
—
—
1
—
—
2
3
4
5
4
6
—
1
—
—
2
3
4
6
8
6
10
1
—
—
2
3
4
6
9
12
10
16
1
2
—
3
5
7
10
15
20
16
25
2
—
3
S
8
1t
16
24
32
25
35
3
4
5
6
13
18
25
38
50
35
50
4
5
?
11
18
25
35
53
70
50
70
5
8
10
15
25
35
50
75
too
70
120
7
11
14
21
35
49
70
105
t40
120
185
12
18
24
36
60
95 120
143 180
190 240
150
240
13
20
26
39
65
130
195
260
185
300
15
23
30
46
77
154
231
308
240
19
28
38
57
96
192
283
284
300
24
36
46
72
120
240
360
480
lac
network l*Aï
lac
Shorl circuit currenl at Isc load side (kA)
100
65
51
42
30
19
10
7
?
10
62
49
41
29
19
10
7
5
80
58
47
39
29
18
10
7
5
70
52
44
37
28
18
10
6
5
M
47
40
35
27
18
9
6
5
41
36
32
25
17
9
6
5
45
38
34
30
24
17
9
6
5
40
35
32
28
23
16
9
6
5
35
31
28
26
21
16
9
6
1
30 25
27 23
25 22
23 20
20 18
IS 14
9 9
6 6
5 5
»
rafc
11
9
6
5
15
14
14
13
12
11
9
7
6
4
10
10
10
9
9
8
7
6
5
4
7
7
7
7
6
6
5
5
4
3
5
5
5
5
5
4
4
3
3
4
4
4
4
4
4
3
3
3
2
Cable (mm*) Cu
Al
Cable lengm (m)
1.5
2.5
—
—
—
—
1
—
2
3
5
«
4
—
—
—
1
2
3
4
'6
8
4
6
—
—
1
2 3
3 4
4
6
8
12
6
10
-
1
2
6
9
13
19
10
16
—
2
3
5
7
10
15
20
30
16
25
2
3
5
e
t»
16
24
32
48
25
35
4
5
8
13
17
25
38
50
75
35
50
5
7
11
18
24
35
53
70
105
50
70
9
12
18
30
42
60
69
120
179
70
120
11
15
23
38
53
75
113
151
226
95
150
14
19
29
48
66
95
143
190
285
120
185
18
24
36
60
84
120
180
240 360
150
240
19
26
39
65
91
130
195
?f.Z
391 462
185
300
23
30
46
77
107
154
231
306
240
28
38
57
96
134
192
288
384
576
300
36
48
72
120
168
240
360
460
720
lac
network
OcA)
lac
Short clrcull currenl al Isc load side (kA)
100
45
•40
25
20
12
8
5
4
3
N
45
35
25
20
12
8
S
4
3
'60
45
35
25
15
12
6
5
'4
3
70
40
35
25
15
12
S
5
4
3
60
40
35
25
15
12
8
5
4
3
H
35
30
25
15
12
8
5
4
3
45
35
30
25
15
12
8
5
4
3
■10
30
30
25
15
12
8
5
4
3
35
30
25
20
15
ta
6
5
4
3
30
25
25
20
15
10
7
5
.4
3
25
25
20
20
12
10
7
5
4
3
22
22
20
17
12
10
7
5
4
3
15
15
15
12
10
6
5
4
3
10
10
10
10
a
1
6
4
3
2
7
7
6
6
6
5
4
4
3
2
S
5
5
4
4
4
3
3
2
2
4
4
4
4
3
3
3
2
2\ 2
Example:
A value (67m) lower than 70 m cable length is selected on the row corresponding lo 95 mm? cable (Cu) section in 380V panel Short circuit current to occur is found as 11 kA by intersection this column with ihe row giving a higher value fisc 22 kA) of Ihe 20 KA shon circuit current al network direction. Short circuil breaking capacity of ihe circuit breaker to be used at Ihis point should be higher than (Icu) 11 kA.