catalogue search
|
You may also be interested in
EMC filter, Ni-MH battery, Smoothed power supply, Redundancy module, Ni-Cd battery
Text version of the page
approx.
0,30kg
approx.
0,30kg
- konform
Range of adjustment
output voltage
Type
Power
Dimensions (W x H x D)
Weight
Order-No.
Efficiency
Nominal output current
Switch mode DC power supply
type SNT14
P.O. Box 1521
22905 Ahrensburg Germany
Phone : +494102 - 42082
Telefax: +494102 - 40930
E-Mail : info@feas.de
Internet: www.feas.de
85 - 270Volt
120Volt - 400Volt
0 - 400 Hz
380.000 h
5 kVac in accordance to VDE 0551
Primary circuit - secondary circuit 3,75 kVac
acc. to VDE 0806 / IEC 380
in acc. to VDE 0871 B, EN 55022/B
Class 2
95% relative humidity, yearly average dewing
allowed for use in tropical ambient
IP 65
IP 20 (VGB4)
>30g at 33Hz in X,Y and Z,
acc. to IEC 60068-2-27
on rails according to DIN 46277
see table below
< 50 mVpp
VDE 0100, 0110, 0113, 0551, 0160/W2, 0806
IEC 60950,IEC61000-6-1-2-3-4,IEC60068-2-3
EN60950,EN50081-1,EN50081-2,EN50082-1
CSA-C 22.2 / UL60950, UL508, UL1950, UL94
EN61000-6-1-2-3-4,EN50178,EN55022
EN55011,EN61000-3-3,EN50204,EN61558-2-17
EN60204,EN60529,EN61000-4-2-3-4-5-6-8-11
EN60068-1,EN60068-2-1-2-3-6-27-30
EN45501,EN50021
IEC 60068-2-11-52,IEC 60529,IEC 380
at 115VAC max. 0,37A / at 230VAC max. 0,17A
Transient voltage suppressor Varistor
PELV (EN60204), SELV (EN 60950)
Nominal output voltage
see table below
Input current peak
Output data
Output voltage U
Current limiting
Control data
Control deviation load
Control deviation supply
Control time
Operating data
Duty circle
Operating temperature range
Derating
Storage temperature range
Cooling
Safety devices
Fuse for input
Fuse for output
Overload protection
Hold-up time
MTBF
Safety data
Test voltage transformer
High voltage resistance
Degree of EMI suppresion
Protection class
Ambient humidity
Protective class enclosure
Protective class terminals
Vibration proof
Applied construction regulations
Nominal
Input voltage AC
Inputvoltage DC
Input data
Residual ripple (20MHz)
according to VDE
IEC
EN
CSA / UL
Mounting
Mechanics
Input current at nominal load
Protective circuit
Extra low safety potential
Output current INominal
Technical data
Output separated according to VDE 0551
Extra low safety potential
PELV (EN 60204), SELV (EN 60950)
Overload- and open circuit protected
short circuit proof
Suitable for the tropics - Epoxy resin casted
Operating status shown by LED
Safety acc. to VDE, EN, UL, CSA
Parallel connection possible
approx.
0,30kg
approx.
0,30kg
75,0
22,5
98,5
5,0VDC
SNT1405
3,0Amp.
15Watt
72%
22,5x75x98,5
586705
12,0VDC
SNT1412
1,8Amp.
21,6Watt
78%
22,5x75x98,5
586712
4,7 - 5,3VDC 10,5-17,5VDC
15,0VDC
SNT1415
1,5Amp.
22,5Watt
80%
22,5x75x98,5
586715
10,5-17,5VDC
24,0VDC
SNT1424
1,0Amp.
24Watt
81%
22,5x75x98,5
586724
22,5-30,0VDC
|