5,0VDC SNT1205 2,5Amp. 12,5Watt 72% 22,5x75x98,5 58205 12,0VDC SNT1212 1,4Amp. 16,8Watt 77% 22,5x75x98,5 58212 4,7 - 5,3VDC 10,5-17,5VDC 15,0VDC SNT1215 1,1Amp. 16,5Watt 77% 22,5x75x98,5 58215 10,5-17,5VDC 24,0VDC SNT1224 0,7Amp. 16,8Watt 79% 22,5x75x98,5 58224 22,5-30,0VDC approx. 0,30kg approx. 0,30kg - konform Range of adjustment output voltage Type Power Dimensions (W x H x D) Weight Order-No. Efficiency Nominal output current Switch mode DC power supply type SNT12 P.O. Box 1521 22905 Ahrensburg Germany Phone : +494102 - 42082 Telefax: +494102 - 40930 E-Mail : info@feas.de Internet: www.feas.de 85 - 270Volt 120Volt - 400Volt 0 - 400 Hz 380.000 h 5 kVac in accordance to VDE 0551 Primary circuit - secondary circuit 3,75 kVac acc. to VDE 0806 / IEC 380 in acc. to VDE 0871 B, EN 55022/B Class 2 95% relative humidity, yearly average dewing allowed for use in tropical ambient IP 65 IP 20 (VGB4) >30g at 33Hz in X,Y and Z, acc. to IEC 60068-2-27 on rails according to DIN 46277 see table below < 50 mVpp VDE 0100, 0110, 0113, 0551, 0160/W2, 0806 IEC 60950,IEC61000-6-1-2-3-4,IEC60068-2-3 EN60950,EN50081-1,EN50081-2,EN50082-1 CSA-C 22.2 / UL60950, UL508, UL1950, UL94 EN61000-6-1-2-3-4,EN50178,EN55022 EN55011,EN61000-3-3,EN50204,EN61558-2-17 EN60204,EN60529,EN61000-4-2-3-4-5-6-8-11 EN60068-1,EN60068-2-1-2-3-6-27-30 EN45501,EN50021 IEC 60068-2-11-52,IEC 60529,IEC 380 at 115VAC max. 0,3A / at 230VAC max. 0,15A Transient voltage suppressor Varistor PELV (EN60204), SELV (EN 60950) Nominal output voltage see table below Input current peak Output data Output voltage U Current limiting Control data Control deviation load Control deviation supply Control time Operating data Duty circle Operating temperature range Derating Storage temperature range Cooling Safety devices Fuse for input Fuse for output Overload protection Hold-up time MTBF Safety data Test voltage transformer High voltage resistance Degree of EMI suppresion Protection class Ambient humidity Protective class enclosure Protective class terminals Vibration proof Applied construction regulations Nominal Input voltage AC Inputvoltage DC Input data Residual ripple (20MHz) according to VDE IEC EN CSA / UL Mounting Mechanics Input current at nominal load Protective circuit Extra low safety potential Output current INominal Technical data Output separated according to VDE 0551 Extra low safety potential PELV (EN 60204), SELV (EN 60950) Overload- and open circuit protected short circuit proof Suitable for the tropics - Epoxy resin casted Operating status shown by LED Safety acc. to VDE, EN, UL, CSA Parallel connection possible 75,0 22,5 98,5 approx. 0,30kg approx. 0,30kg

pageCatalog pdf di En 2012-05-22-29